292 resultados para Removable partial prosthesis
Resumo:
Background: The aim of the present study was to evaluate clinical and radiographic changes that occur around dental implants inserted in different levels in relation to crestal bone under different restoration protocols.Methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at crestal bone level), Minus 1 (1 mm below crestal bone), or Minus 2 (2 mm below crestal bone). Each hemimandible was submitted to a restoration protocol: conventional (prosthesis was installed 120 days after implant placement, including 30 days with healing cap) or immediate (prosthesis was installed 24 hours after implant placement). Fixed partial prostheses were installed bilaterally in the same day. After 90 days, clinical and radiographic parameters were evaluated.Results: As long as the implants were inserted in more apical positions, the first bone-to-implant contact (fBIC) was positioned more apically (P<0.05). However, the apical positioning of the implants did not influence the ridge loss or the position of the soft tissue margin (PSTM) (P>0.05). In addition, in immediately restored sites, the PSTM was located significantly more coronally than that in conventionally restored sites (P=0.02).Conclusions: Despite the more apical positioning of the fBIC, the height of the peri-implant soft tissues and ridge was not jeopardized. Moreover, the immediate restoration protocol was beneficial to the maintenance of the PSTM. Further studies are suggested to evaluate the significance of these results in longer healing periods.
Resumo:
This clinical report describes a method to reduce the number of clinical sessions for the rehabilitation of implant-supported fixed dentures through a simplified and versatile procedure indicated mainly for immediate loading. According to this method, the immediate implant-supported fixed dentures for edentulous patients can be safely fabricated within 2 days. In this technique, the teeth in the wax are prepared on a base of light-polymerized resin, and both wax teeth and metallic superstructure trials are accomplished at the same session.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Direct relining of dentures made with hard chairside reline resins is faster than laboratory-processed reline systems and the patient is not without the prosthesis for the time necessary to perform the laboratory procedures. However, a weak bond between the autopolymerizing acrylic reline resins and the denture base material has been observed. This study evaluated the effect of six different surface treatments on the bond strength between a hard chairside reline acrylic resin and ia heat-cured acrylic resin. Specimens of the heat-cured acrylic resin were divided into seven groups. one of these groups remained intact. In the other groups, a 10-mm square section was removed from the centre of each specimen. The bonding surfaces were then treated with (i) methyl methacrylate monomer, (ii) isobutyl methacrylate monomer, (iii) chloroform, (iv) acetone, (v) experimental adhesive and (vi) no surface treatment-control group. Kooliner acrylic resin was packed,into the square sections and polymerized. The bonding strength was evaluated by a three-point loading test. The results were submitted to one-way analysis of variance (ANOVA) followed by a Tukey multiple range test at a 5% level of significance. No significant difference was found between the surface treatment with Lucitone 550 monomer or chloroform, but both were stronger than the majority of the other groups. The bond strength provided by all the surface treatments was lower than that of the intact heat-cured resin.
Resumo:
Purpose: This in vitro study compared the dimensional accuracy of a stone index and of two impression techniques (squared impression copings and modified squared impression copings) for implant-supported prostheses. Materials and Methods: A master cast with four parallel implant-abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Three groups of impressions were tested (n = 5): index (1), squared (S), and modified squared (MS). The measurement method employed was just one titanium screw tightened to the framework. The measurements (60 gap values) were analyzed using software that received the images from a video camera coupled to a stereomicroscope at x 100 magnification. The results were evaluated statistically (analysis of variance, Holm-Sidak method, alpha = .05). Results: The mean abutment/framework interface gaps were: master cast = 31.63 mu m; group I = 45.25 mu m; group S = 96.14 mu m; group MS = 51.20 mu m. No significant difference was detected among the index and modified squared techniques (P = .05). Conclusion: Under the limitations of this study, the techniques modified squared and index generated more accurate casts than the squared technique. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:715-721
Resumo:
Purpose: To investigate, in vitro, the dimensional accuracy of two impression techniques (squared impression copings and squared impression copings sandblasted and coated with impression adhesive) made of vinyl polysiloxane and polyether impression materials. Materials and Methods: A master cast (control group) with four parallel implant abutment analogs, a passive framework, and a custom aluminum tray was fabricated. Four groups (n = 5 each group) were tested: squared Impregum (SI), squared Express (SE), sandblasted adhesive squared Impregum (ASI), and sandblasted adhesive squared Express (ASE). The measurement method employed was just one titanium screw tightened to the framework. A stereomicroscope was used to evaluate the fit of the framework by measuring the size of the gap between the abutment and the framework. The results were analyzed statistically. Results: The mean values for the abutment/framework interface gaps were: master cast, 31.63 mu m (SD 2.16); SI, 38.03 mu m (SD 9.29); ASI, 46.80 mu m (SD 8.47); SE, 151.21 mu m (SD 22.79); and ASE, 136.59 mu m (SD 29.80). No significant difference was detected between the SI or ASI techniques and the master cast. No significant difference was detected between the SE and ASE techniques. Conclusion: Within the limitations of this study, it can be concluded that Impregum Soft medium consistency was the best impression material and the impression technique did not influence the accuracy of the stone casts. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:771-776
Resumo:
Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). Results: The mean gap value with the index technique was 27.07 mu m. With the conventional pouring technique, the mean gap values were 116.97 mu m for the tapered group, 5784 mu m for the squared group, and 73.17 mu m for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 mu m for the tapered group, 38.03 mu m for the squared group, and 82.47 mu m for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 jum for the tapered group, 74.19 mu m for the squared group, and 104.67 mu m for the squared splinted group. No significant difference was detected among Index, squarellatex techniques, and master cast (P > .05). Conclusions: The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.
Resumo:
Objectives: To verify the consequences of implant-supported fixed oral rehabilitation on the quality of life (QL) of elderly individuals.Material and methods: Fifteen patients were studied, being 10 females and five males; all were aged > 60 years, were completely edentulous, wore removable dentures on both arches, and were treated with implant-supported fixed dentures. Three QL questionnaires were applied, two related to the oral conditions (Oral Impact on Daily Performance - OIDP - and Oral Health Impact Profile, short version - OHIP-14) and one dealing with global aspects (World Health Organization Quality of Life - WHOQOL-BREF), before 3, 6, and 18 months after surgical placement of implants.Results: Scores in the OIDP and OHIP-14 questionnaires were better after dental treatment. The WHOQOL-BREF was less sensitive, confirming the higher reliability of specific questionnaires (focal) compared with general questions in such situations.Conclusion: Treatment with implant-supported fixed prostheses improved QL in the elderly; these effects are better detected by specific instruments focused on the subject.
Resumo:
Portuguese chestnut (Castanea sativa) is used for forest products, raw nuts and processed flour, paste, and candy. We studied the influence on germination efficiency of seed with and without partial tegument removal combined with different substrate composition (coconut fiber, pine compost and vermiculite) at São Paulo State University, Campus of Botucatu, São Paulo, Brazil. Randomized blocks were used in a factorial scheme 3x2 (three substrates x two seed types) consisting of six treatments with five replications (twelve seeds). Seeds were sowed in expanded polystyrene trays, with 72 cells, and maintained at 25 C under controlled environment. Rate, time elapsed and speed of seed germination was submitted to ANOVA and the average compared using Tukey's 5% test of probability and curves adjusted based on Gompertz regression. Coconut fiber or vermiculite associated with seed without partial tegument removal showed the highest germination rate, and coconut fiber with or without partial tegument removal displayed the fastest speed of seed germination.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Partial cDNA sequences of myosin V from rainbow trout Oncorhynchus mykiss were analyzed and showed high similarity to MVa from other vertebrates. Phylogenetic analysis has shown that events resulting in the formation of paralogous copies of myosin Va, Vb, and Vc occurred before the divergence of vertebrates into different classes. Expression analysis of myosin Va, Vb, and Vc in different O. mykiss tissues revealed MVa exclusively expressed in hypophysis and brain whereas Vb and Vc were expressed in practically all tissues analyzed. The nucleotide sequence for myosin V was explored in a fish species for the first time and these results represent an important start in understanding the organization, evolution, and expression of myosins in early vertebrates. The data presented here represent contributions to the knowledge of rainbow trout genome. A better understanding of this economically important species could assist in development of improved strains of this fish for aquaculture.
Resumo:
O presente estudo consiste em uma caracterização preliminar da atividade proteolítica de frações de proteínas purificadas a partir de lisados de trofozoítos de cepa isolada e axenizada no Brasil. Frações obtidas por cromatografia líquida (FPLC) foram analisadas quanto ao perfil eletroforético em géis de poliacrilamida (SDS-PAGE) e a atividade proteolítica foi avaliada em géis contendo gelatina como substrato. A caracterização das enzimas foi realizada a partir da análise do efeito de inibidores sintéticos de cisteína-proteases (E-64, IAA), serina-proteases (PMSF), serina e cisteína-proteases (TPCK, TLCK, elastatinal), metalo-proteases (EDTA) e aspartil proteases (pepstatina) sobre a degradação do substrato. Entre 30 frações eluídas, bandas de proteínas foram observadas em oito delas, entretanto, atividade proteolítica foi detectada apenas nas frações 23, 24, 25 e 26. O perfil eletroforético das proteínas revelou poucas bandas distribuídas na faixa de 45 a 18 kDa. Os zimogramas revelaram zonas de proteólise na faixa de aproximadamente 62 a 35 kDa, entretanto destacaram-se as bandas de hidrólise de 62, 55, 53, 50, 46 e 40 kDa. Nos ensaios de inibição, a proteólise foi marcantemente inibida por E-64, TPCK, TLCK e elastatinal. Redução discreta da proteólise foi observada com IAA e PMSF, enquanto que EDTA e pepstatina não promoveram alteração dos perfis de hidrólise. Estas observações são relevantes, especialmente se considerarmos que para elucidar o envolvimento das proteases na relação parasita-hospedeiro, a purificação dessas moléculas é um requisito importante.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Rhizopus stolonifer was cultivated in wheat bran to produce a cellulase-free alkaline xylanase. The purified enzyme obtained after molecular exclusion chromatography in Sephacryl S-200 HR showed optimum temperature as 45 degrees C and hydrolysis pHs optima as pH 6.0 and 9.0. Xylanase presented higher Vmax at pH 9.0 (0.87 mu mol/mg protein) than at pH 6.0 and minor Km at pH 6.0 (7.42 mg/mL)than at pH 9.0.
Resumo:
The 3'-terminal 853 nt (and the putative 283 aa) sequence of the VP2-encoding gene from 29 field strains of porcine parvovirus (PPV) were determined and compared both to each other and with other published sequences. Sequences were examined using maximum-parsimony and statistical analyses for nucleotide diversity and sequence variability. Among the nucleotide sequences of the PPV field strains, 26 polymorphic sites were encountered; 22 polymorphic sites were detected in the putative amino acid sequence. Mapping polymorphic sites of protein data onto the three-dimensional (3D) structure of PPV VP2 revealed that almost all substitutions were located on the external surface of the viral capsid. Mapping amino acid substitutions to the alignment between PPV VP2 sequences and the 3D structure of canine parvovirus (CPV) capsid, many PPV substitutions were observed to map to regions of recognized antigenicity and/or to contain phenotypically important residues for CPV and other parvoviruses. In spite of the high sequence similarity, genetic analysis has shown the existence of at least two virus lineages among the samples. In conclusion, these results highlight the need for close surveillance on PPV genetic drift, with an assessment of its potential ability to modify the antigenic make-up of the virus.