391 resultados para Preparo dental
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective. To evaluate the effectiveness of the color change of hybrid light-emitting diode (LED) and low-intensity infrared diode laser devices for activating dental bleaching and to verify the occurrence of a color regression with time. Material and methods. A total of 180 specimens obtained from human premolars were immersed in a coffee solution for 15 days for darkening and then divided into eight experimental groups (n = 20 in each) as follows: G1, bleaching without light; G2, bleaching with halogen light; G3, bleaching with a blue LED (1000 mW/470 nm) and a laser device (120 mW/795 nm) simultaneously; G4, bleaching with an LED emitting blue light (1000 mW/470 nm); G5, bleaching with a blue LED (800 mW/470 nm) and a laser device (500 mW/830 nm) simultaneously; G6, bleaching with a blue LED device (800 mW); G7, bleaching with a green LED (600 mW/530 nm) and a laser device (120 mW/795 nm) simultaneously; and G8, bleaching with a green LED (600 mW). Three measurements were performed (at baseline and 14 days and 12 months after bleaching) using a Vita Easyshade spectrophotometer. The data were submitted to two-way ANOVA and a Tukey test. Results. All groups showed significantly higher Delta E values than Group G1, with the exception of Group G8. Variations in the Delta E values at 14 days were significant when compared with those obtained at baseline and after 12 months. Conclusions. Light activation of the bleaching gel provided faster and more intense bleaching than use of the bleaching gel without light activation. Combinations of low-intensity diode lasers are ineffective as a bleaching gel activator. Color regression was observed after 12 months of storage.
Resumo:
Statement of the Problem: The effectiveness of low-intensity red laser for activating a bleaching gel and its effect in pulp temperature was not investigated in dental literature. Purpose: The objective of this study was to assess the effectiveness of low-intensity red laser for activating a bleaching gel, as well as its effect in temperature of the bleaching gel and the dental pulp. Materials and Methods: Forty extracted bovine teeth were immersed in a solution of coffee 14 days for darkening. The initial colors were recorded by spectrophotometric analysis. The specimens were randomly distributed into two groups (N = 20): the control, which did not receive light and the experimental group that received light from an appliance fitted with three red light-emitting laser diodes (? = 660 nm). A green-colored, 35% H2O2based bleaching gel was applied for 30 minutes, and changed three times. After bleaching, the colors were again measured to obtain the L*a*b* values. Color variation was calculated (?E) and the data submitted to the non-paired t-test (5%). To assess temperature, 10 human incisors were prepared, in which one thermocouple was placed on the bleaching gel applied on the surface of the teeth and another inside the pulp chamber. Results: There was a significant difference between the groups (p = 0.016), and the experimental group presented a significantly higher mean variation (7.21 +/- 2.76) in comparison with the control group (5.37 +/- 1.76). There was an increase in pulp temperature, but it was not sufficient to cause damage to the pulp. Conclusion: Bleaching gel activation with low-intensity red laser was capable of increasing the effectiveness of bleaching treatment and did not increase pulp temperature to levels deleterious to the pulp. CLINICAL SIGNIFICANCE The application of a low-intensity red laser was effective for activating a bleaching gel with green dye, without any deleterious increases in pulpal temperature. (J Esthet Restor Dent 24:126134, 2012)
Resumo:
Purpose: The purpose of this study was to evaluate the cohesive strength of the composite using different resinous monomers to lubricate instruments used in the Restorative Dental Modeling Insertion Technique (RDMIT).Materials and Methods: The composite specimens were made by using a prefabricated Teflon device. Different resinous monomers were used at the interface to lubricate the instruments, for a total of 72 specimens divided into 6 groups: 1. control group, no resinous monomer was used; 2. Composite Wetting Resin; 3. C & B Liquid; 4. Scotchbond Multi-Purpose Adhesive; 4. Adper Single Bond Adhesive; 6. Prime & Bond NT. Specimens were submitted to the circular area tensile test to evaluate the cohesive strength at the composite interfaces. Data were analyzed using ANOVA and Tukey's test (alpha = 0.05).Results: ANOVA showed a value of p < 0.0001, which indicated that there were significant differences among the groups. The means (SD) for the different groups were: Adper Single Bond Adhesive: 26 (12) a; control group: 28 (3) ab; Prime & Bond NT: 32 (12) ab; Composite Wetting Resin: 36 (9) abc; C&B Liquid: 38 (7) bc; Scotchbond Multi-Purpose Adhesive: 46 (10) c. Groups denoted with the same letters were not significantly different. Only Scotchbond Multi-Purpose Adhesive, used for direct restorations, had a statistically significantly higher bond strength than the control group, Adper Single Bond Adhesive, and Prime & Bond NT. Adper Single Bond with Adhesive showed a statistically significantly lower mean value than C & B Liquid.Conclusion: The results of this study indicate that the resinous monomers used for lubricating the instruments in the RDMIT did not alter the mechanical properties of the composite, and therefore did not reduce the cohesive bond strength at the composite interfaces.
Resumo:
Purpose: This study compared five types of chemical catalyzing agents added to 35% hydrogen peroxide gel, with regard to their capacity of intensifying in-office dental bleaching results.Methods: One-hundred and twenty bovine incisors were used, of which the crowns and roots were cut in the incisor-apical direction, to acquire the dimensions of a human central incisor. The specimens were sectioned in the mesiodistal direction by means of two longitudinal cuts, the lingual halves being discarded. The vestibular halves received prophylaxis with a bicarbonate jet, ultrasound cleaning and acid etching on the dentinal portion. Next, the specimens were stored in receptacles containing a 25% instant coffee solution for two weeks. After the darkening period, initial measurement of the shade obtained was taken with the Easy Shade appliance, which allowed it to be quantified by the CIELab* method. The samples were divided into six groups, corresponding to the chemical activator used: a) none (CON); b) ferric chloride (CF); c) ferrous sulphate (SF); d) manganese gluconate (GM); e) manganese chloride (CM); f) mulberry root extract (RA). Each group received three 10-minute applications of the gels containing the respective activating agents. Next, a new shade measurement was made.Results: The Analysis of Variance and Tukey tests (alpha=5%) showed statistically significant differences for the shade perception values (p=0.002). Groups GM, CM and RA showed significantly higher means than the control group.Conclusion: The presence of some chemical activators is capable of resulting in a significant increase in tooth shade variation.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to evaluate the micro-shear bond strength of 5 adhesive systems to enamel, one single-bottle acid-etch adhesive (O), two self-etching primers (P) and two all-in-one self-etching adhesives (S). Method: Sixty premolar enamel surfaces (buccal or lingual) were ground flat with 400- and 600-grit SiC papers and randomly divided into 5 groups (n=12), according to the adhesive system.. SB2 - Single Bond 2 (O); CSE - Clearfil SE Bond (P); ADS - AdheSE (P); PLP - Adper Prompt L-Pop (S); XE3 - Xeno III (S). Tygon tubing (inner diameter of 0.8mm) restricted the bonding area to obtain the resin composite (Z250) cylinders. After storage in distilled water at 37 degrees C for 24h and thermocycling, micro-shear testing was performed (crosshead speed of 0.5mm/min). Data were submitted to one-way ANOVA and Tukey test (a=5%). Samples were also subjected to stereomicroscopic and SEM evaluations after micro-shear testing. Mean bond strength values (MPa +/- SD) and the results of Tukey test were: SB2: 36.36(+/- 3.34)a; ADS: 33.03(+/- 7.83)a; XE3: 32.76(+/- 5.61)a; CSE: 30.61(+/- 6.68)a; PLP: 22.17(+/- 6.05)b. Groups with the same letter were not statistically different. It can be concluded that no significant difference was there between SB2, ADS, XE3 and CSE, in spite of different etching patterns of these adhesives. Only PLP presented statistically lower bond strengths compared with others. J Clin Pediatr Dent 35(3): 301-304, 2011
Resumo:
This study aimed to describe how to evaluate and quantify the ergonomic satisfaction level of dental clinics rooms. Requirements for design, production and selection of dental equipment as described in ISO/TC-106/SC-6-N-411, support more comprehensive studies for an ergonomic evaluation and ergo design of the dental workstations. It was created a checklist of ergonomics requirements which is supported by Standards ISO/FDI and acquired by mean of a literature review. According to information exposed at the document of the Ergonomics Society of Dental Ergonomics - ESDE we can consider that the elaboration of an ergonomic evaluation protocol regard to the dental workstation is an important demand for the ergonomics, particularly in relation to the performance of the ergonomic design which presents qualified to assist to dental equipment manufactures. By this means, the identification of the evaluation factors pointed in ISO/TC 106/SC 6 N 411 offers the basic information to the process of elaboration of this protocol addressed by the described general guidelines.
Resumo:
The corrosion resistance of three of the constituent phases in high copper dental amalgams has been investigated by electrochemical methods in 0.9% NaCl solution. Polarization curves show corrosion potentials most positive for gamma(1)-Ag2Hg3, followed by Ag-Cu, and gamma-Ag3Sn in agreement with the order of corrosion resistance deduced from the corrosion currents. Complex plane impedance plots at the open circuit potential showed distorted semicircles with diffusional components at low frequency for Ag-Hg and Ag-Cu, while for gamma-Ag3Sn a layer of corrosion products is formed, partially or completely covering the surface of the electrode. Impedance and noise spectra have been compared in the frequency domain, and show good agreement. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Dental amalgams, formed by reaction of mercury with a powder alloy containing mainly Ag, Sn, Cu and Zn, have a complex metallurgical structure which can contain up to six phases. Their observed corrosion is thus a complex process, which involves contributions from each of the phases present as well as intergranular corrosion. It is thus of interest to investigate the corrosion of individual phases present in dental amalgams. In this work the corrosion behaviour in 0.9% NaCl solution of Ag-Hg, Ag-Sn and Sn-Hg phase components of dental amalgams was investigated by electrochemical methods. The corrosion resistance was found to decrease in the order gamma (1)-Ag2\Hg3, gamma -Ag3Sn and gamma (2)-Sn7Hg. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Metallographic studies by scanning electron microscopy and energy dispersive spectroscopy carried out for two types of dental amalgam showing a porous multiphase material. Surface analysis shows that the structure of the Dispersalloy amalgam consists of gamma-Ag3Sn, gamma(1)-Ag2Hg3, eta'-Cu6Sn5, epsilon-Cu3Sn and eutectic Ag-Cu phases. while Velvalloy amalgam consists mainly of gamma, gamma(1) and gamma(2)-Sn7-8Hg phases. The latter phase presents an uniform distribution often associated with voids.
Resumo:
Esferas de poliestireno foram obtidas através da polimerização do estireno sem a presença de emulsificante. A suspensão foi caracterizada por Espalhamento de Luz e Microscopia Eletrônica de Transmissão apresentando monodispersidade com tamanho em torno de 463 nm. O método de deposição vertical foi utilizado para preparar filmes em substratos de vidro a partir da suspensão de esferas. Filmes de opalas de alta qualidade foram obtidos e caracterizados por Espectroscopia de Reflectância, Microscopia Eletrônica de Varredura e Microscopia Óptica.
Resumo:
O objetivo deste trabalho foi analisar a morfologia dos cimentos Sealapex, Apexit, Sealer 26 (cimentos a base de hidróxido de cálcio) e Ketac Endo (cimento de ionômero de vidro), através da microscopia de força atômica, verificando-se as características de suas partículas após a obturação dos canais radiculares e após um período de seis meses de contato com o plasma sanguíneo humano. Utilizaram-se 16 dentes unirradiculares humanos extraídos e incluídos em blocos de resina após o preparo biomecânico. As raízes foram divididas em quatro grupos de quatro raízes cada e os canais radiculares obturados pela técnica de condensação lateral passiva com os cimentos em estudo. Verificou-se que o cimento Apexit foi o que mais sofreu desintegração após seis meses de imersão em plasma sanguíneo humano, seguido pelo Ketac Endo e Sealapex. Dentre todos os cimentos estudados, o Sealer 26 mostrou-se o mais uniforme e com a menor desintegração.
Resumo:
Além da produtividade física e da conservação do solo, o cultivo protegido e o preparo do solo, na olericultura, requerem altos investimentos, muito trabalho e insumos externos. Assim, o objetivo deste trabalho, foi identificar combinações entre ambiente, preparo do solo e época de plantio capazes de melhorar o desempenho econômico e a produtividade da cultura da alface em cultivo orgânico, em Rio Branco, Acre. O cultivo foi realizado em quatro tipos de ambientes: 1 - sombreamento proporcionado em 52% sob latada de maracujá; 2 - 35% de sombreamento sob estufa; 3 - 50% sob tela de sombreamento; e, 4 - cultivo a pleno sol (testemunha), considerando cada ambiente como um experimento, que avaliou-se três preparos de solo (plantio direto, cultivo mínimo e preparo convencional) em duas épocas de plantio (estiagem e chuvosa), sob delineamento de blocos ao acaso, com quatro repetições. Considerou-se como custo de produção a soma de todos os valores (insumos) e operações (serviços) utilizados no processo produtivo, incluindo-se os respectivos custos alternativos ou de oportunidade e a depreciação das instalações. O cultivo em estufa e sob tela de sombreamento aumenta a produtividade em época de estiagem, enquanto em época chuvosa, a produtividade é maior em cultivo sob estufa. O plantio direto e cultivo mínimo a pleno sol ou cultivo mínimo sob tela de sombreamento promovem maior produtividade no preparo convencional do solo. Proporcionam lucro supernormal (RMe > CTMe): o cultivo na época chuvosa (verão); sob sombreamento de latada de maracujá-amarelo; a pleno sol; o preparo convencional do solo sob latada e o plantio direto a pleno sol.