173 resultados para Pessoa em potência
Resumo:
Pós-graduação em Educação Sexual - FCLAR
Resumo:
The aim of this study was to examine changes on anaerobic power after competitive period in professional soccer players. Twenty five male was evaluated before (PRE) and after (POS) competitive period. To assess anaerobic power was used running based on anaerobic sprint test (RAST), which were determined the maximum power (MAXP), medium power (MEDP), minimum power (MINP) and fatigue index (FI). The test was performed in the first (PRE) and the last (POS) training session of competitive period, wich lasted 20 weeks. There were no significant difference (p>0,05) in POS condition compared to PRE condition on MAXP (10,70 ± 0,95 vs 10,83 ± 0,87), MINP (8,48 ± 0,92 vs 8,28 ± 0,76), MEDP (9,52 ± 0,83 vs 9,41 ± 0,61) and FI (22,73 ± 7,48 vs 25,53 ± 8,79). There was no significant change on anaerobic power after a competitive period wich lasted 20 weeks in professional soccer players.
Resumo:
This paper presents the development and the main results for an interleaved boost rectifier operating as a special input power stage for a trolleybus type vehicle, allowing its feeding by alternate current (AC) or direct current (DC) distribution power systems. When feeding with two wires (single phase) alternate current distribution system, the converter accomplish active power factor correction, providing a relatively sinusoidal current with low total harmonic distortion (THD) and fully complying with IEC 61000-3-4 standards. In addition, a management control system promotes the required automatic operation changes for the proposed rectifier when the vehicle is changing from the DC distribution power system to the AC distribution power system and vice-versa, keeping its original electrical DC system characteristics for the adjustable speed driver sub-system. The main experimental results for a prototype rated at 150kW are presented, considering its application for a trolleybus with DC adjustable speed driver, demonstrating the proposed converter benefits and the possibility of AC feeding system for trolleybus type vehicle.
Resumo:
The effect of physical exercise in immune function has been extensively studied. The intensity and duration of physical exercise have considerable influence in immunologic parameters. However, few studies have compared different exercise intensities in different stages of a physical training program. Thus, the aim of this study was to verify the metabolic, hormonal and immunologic changes before and after acute intermittent swimming exercise, following different stages of training program. Seventeen male swimmers were evaluated in three stages of training. The intensity of the three sessions was 90% (anaerobic potency – PAN), 70% (aerobic potency - PAE) and 98% (lactate tolerance – TLA) of the maximal speed from the best time of the distance, resulted from peak performance in competition. Blood samples were collected pre and immediately after exercise for cells counting and measurement of substrates and cortisol concentrations. It was used ANOVA to verify the significance of difference (p<0.05). There was a significant increase of glucose and cortisol post exercise in the PAN and PAE sessions. Glutamine increased significantly in PAE and TLA. Leukocytes increased significantly after the three different sessions and lymphocytes decreased significantly on PAE and TLA. In conclusion, it was demonstrated that changes of the several parameters studied in different stages of training program can cause temporary alterations in immune cells and may compromise resistance to common minor illnesses and athlete performance.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Para a realização deste experimento, foram utilizados um rebolo de óxido de alumínio instalado em uma retificadora plana, um dispositivo em forma de balança juntamente com o sensor de deslocamento, um sistema de aquisição de sinais e um dressador de ponta única de diamante. O processamento digital dos dados foi obtido com o software Matlab. Nos ensaios, foram aplicados diferentes graus de recobrimento e profundidade de dressagem e comparada a agressividade obtida. A partir dos dados resultantes, os parâmetros RMS, DPO e DPKS mostraram-se bons indicadores para a operação. Também ficou comprovado que para recondicionar e definir novas características para o rebolo é necessária a remoção de 120 um. Do estudo do espectro do dinal de EA, notou-se que não há componentes hormônicas com frequência superior a 200 KHz.
Resumo:
The objective of thisstudy was to verify, using the Ecological Development Theory (EDT), as the practice and swimming learning for People With Disabilities (PWD) causes changes to both the practitioner and in other environments experienced by it as well as the other environments influence the learning to swim. The study included 16 PWD, students linked university extension project, Department of Physical Education of UNESP Bauru, taught by coordinators LAPEF, which aims to includes wimming in the PWD ofevery day life, students linked to an institution of Bauru-SP, three employees of the institution and two swimming project teachers.Interviews with the families of the students were made, with the institution s employees, with the project teachers and analyze thes wimming lessons applied in the project for one semester. Based on the results we can say that the practice and learnings wimming for PWD causes changes to both the practitioner and for other environments experienced by her (home, institution) and also, what other environments experienced by PWD influence in practice and process of learning to swim. Using the terminology of EDT, we conclude that theme so system (home activities institution) influences in the microsystem (swimming lessons) and the microsystem influences the mesosystem, so the activity was significant and temporal persistence influencing the development of PCD.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
É comum nas áreas rurais a utilização de métodos de irrigação que consistem em bombear a água de açudes, lagoas e rios para irrigar a terra onde está sendo cultivada determinada cultura. Em geral esse bombeamento é feito por motores movidos á energia elétrica ou á óleo diesel. Este trabalho visa avaliar os motores elétricos de baixa potência que são usados para irrigar pequenas áreas plantadas através de bombeamento de água de açudes, lagoas etc. Os métodos a serem usados competem á aplicação da Física e do Calculo Diferencial e Integral, através do uso de conceitos,integrais definidas e do uso de sólidos de revolução para simulação. Poderão ser feitas associações entre vazão de água, potência necessária para o serviço, a quantidade de tempo que a reserva de água sustenta o bombeamento. Depois de feito os cálculos pode se concluir sobre o tipo de motor e potencia mais adequada para tal serviço. Este projeto visa avaliar o desempenho de motores elétrico de baixa potencia no bombeamento de água através de métodos pertinentes ao calculo diferencial e integral e ao mesmo tempo poder mostrar uma das várias aplicações desta disciplina. Após os cálculos realizados espera-se obter conclusões sobre os motores elétricos e fazer a associação do serviço que é recomendado para o seu uso. Serão utilizados métodos do cálculo diferencial e Integral para a avaliação do desempenho do motor e conceitos da Física para determinação e associação entre potência dissipada e vazão de água.
Resumo:
The Earth receives annually 1,5.1018 kWh of solar energy, which corresponds to 1000 times the world energy consumption in this period. This fact comes out that, besides being responsible for the maintenance of life on Earth, the solar radiation is in an inexhaustible energy source, with an enormous potential for use by systems capture and conversion into another form of energy. In many applications of low power systems that convert light directly into electricity, called photovoltaic advantageously replace other means of production processes, where its distribution is very significant. The determination of the power generated by such a system is of paramount importance for the design energy of its implementation and evaluation of the system itself. This study aims to determine a relationship between the maximum power generated by solar photovoltaic and characteristic parameters of the generator. This relationship allows to evaluate the performance of such a system. For simulations of the developed equations were used 3 photovoltaic modules with an output of 100 Wp each, and data collection was performed during one year by enrolling in addition to meteorological data, solar irradiance incident on the modules.
Resumo:
A radiação solar constitui-se numa inesgotável fonte energética, havendo um enorme potencial de utilização por meio de sistemas de captação e conversão em outra forma de energia. Para a conversão direta da energia solar em elétrica, são utilizadas células fotovoltaicas constituídas, que associadas constituem um módulo fotovoltaico, sendo que também quando agrupados, formam painéis fotovoltaicos. Estes painéis associados a outros equipamentos que transformam ou armazenam energia elétrica para que ela possa ser utilizada é chamado de sistema fotovoltaico. Neste trabalho, foram determinadas analiticamente formas de obtenção de curvas de corrente e potência fotovoltaicas, e também o ponto de potência máxima. Tais métodos foram aplicados no sistema fotovoltaico localizado na FCA/UNESP, sendo utilizado um sistema constituído por três módulos fotovoltaicos. Para o desenvolvimento das equações que regem a potência dos sistemas fotovoltaicos, procurou-se estudar o circuito elétrico de células fotovoltaicas, sendo necessária também a aplicação de métodos numéricos iterativos para a determinação de alguns parâmetros elétricos. De acordo com os teoremas apresentados, foi possível determinar as expressões analíticas da resistência série e do ponto de potência máxima de uma célula fotovoltaica, possibilitando a geração dos gráficos de tais funções com os dados obtidos experimentalmente. Comparando-se os valores obtidos pelas funções com os valores padrões do sistema fotovoltaico instalado, o valor calculado apresentou um erro de 1,03% em relação ao dado pelo fabricante, representando uma excelente aproximação. Desta forma, pode-se concluir que os métodos e teoremas dos sistemas fotovoltaicos apresentados podem servir de auxílio a futuros dimensionamentos para aplicações destes sistemas.
Resumo:
This work aims to present the electrical behavior of two mechanical processing equipment of wood, the saw vertical tape and the wood chipper. Their characteristics in real operating conditions and the electrical behavior of devices in terms of energy efficiency is shown through the study of individual power factor are presented in this study. It was observed that both devices operate unloaded for some intervals of time and this contributes to a low power factor. It is concluded that improved production planning and better preparation of the operators in the operations of sawing wood, in order to improve the power factor in sawmills is necessary.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)