158 resultados para Ondas produzidas pelo vento


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the quality of weight measurements produced in Primary Health Care Centers in Botucatu and surroundings. 14 Health Care Centers were included, all of them located in four towns in the area of Botucatu (4,555; 5,656; 18,761 and 128,397 inhabitants). General conditions and scale calibration conditions found in those Health Care Centers were evaluated. In order to evaluate the weight accuracy obtained by the local team, 10 adult users of each Center were addressed by the rater during the service routine in order to get a new weight evaluation, immediately after the measurement made by the team. The statistic method applied for checking the weight measurement held in the Heath Care Center and the scales accuracy was the measurement error technique (MET). The results have showed that out of 19 scales, 6 of them overestimated the weight by 50 grams, 1 of them underestimated the weight by 200 grams and the others were accurate. Evaluated as a group, the result of the scale MET was 44.3g. Regarding the conformity of the measures obtained by the MET of the adults weighing in the Health Care Centers compared to the ones obtained by the researcher, the expected result was obtained in only one Center (< 100g). The results have showed data compromise, rather due to lack of health team training than due to the conditions of the equipment used for the measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to build and validate a low cost reduced-scale wind tunnel for drift evaluation on pesticide application technology. The work was carried out at the NEMPA - Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA), FCA/UNESP, Departamento de Engenharia Rural, Botucatu/SP, Brazil. The wind tunnel main characteristics were an open circuit and a closed working section with a fan blowing air into the tunnel. Screens were fitted downstream after the fan in order to stabilize the air flow on the working section. The tunnel was built with 3.0 mm eucalyptus hardboard, with a total length of 4.8 m and a squared section of 0.56 m. The air flow was provided by a 180 W axial fan. The system was adjusted and calibrated to provide a laminar and stable flow at 2.0 m s-1. Validation studies were carried out by using a Teejet XR 8003 flat fan nozzle at 200 kPa (medium droplets) to apply a spray solutions containing water plus a food dye (Blue FDC) at 0,6% m v-1 mixed with two adjuvants: a polymer based anti drift formulation at 0,06% m v-1 and a sodium lauryl ether sulfate based surfactant at 0,2% v v-1. After a 10-second application the drift was collected on nylon strips transversally fixed along the tunnel at different distances from the nozzle and different high from the bottom part of the tunnel. Drift deposits were evaluated by spectrophotometry. The wind tunnel had low levels of turbulence and high repeatability of the data, which means that the flow was uniform and able to be used for carrying out measures to estimate drift. The validation results showed that the tunnel was effective to enable comparative drift measurements on the spray solution used in this work making possible the evaluation of drift risk potential under those spray technologies. The use of an adjuvant based on a polymer reduced the amount of drift from the nozzle compared to the surfactant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the past few years, the area of planted forests has expanded considerably in Brazil, reaching a level of 6.3 million hectares, which represents approximately 0.7% of the country, mainly with some species of the Eucalyptus genus. However, due to the global concern with biological invasions by exotic species, risk assessment is necessary to evaluate the potential of Eucalyptus species escaping cultivated stands and invading surrounding native ecosystems. Seedlings by natural regeneration from Eucalyptus grandis and E. urophylla, pure and hybrids between the two species were evaluated, by assessing natural regeneration of Eucalyptus in 18 sites located in Brazilian states with plantation forest tradition (Minas Gerais, São Paulo, Rio Grande do Sul and Espírito Santo). Sample plots were installed in the planted stands, along forest roads and in a nearby pasture or native vegetation.,at different distances from the Eucalyptus stands. Regeneration of Eucalyptus was not recorded in 90% of the plots installed outside the eucalipt stands. However, seedlings of eucalypts were observed in 29% of the plots within the commercial stands (mean density of 37 seedlings per hectare) and 40% of the plots located along forest roads (157 seedlings per hectare on average), but no adult plants by natural regeneration were found. The seedlings of eucalypt species studied rarely were found beyond the limits of the cultivated areas. In the planted stands or along forest roads, eucalypts can germinate, but the seedlings apparently do not establish. So the potential for invasion by seeds produced in commercial plantations of Eucalyptus is low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy