172 resultados para Invisible brackets


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The orthodontic treatment using lingual brackets has been desired by adult patients for esthetic factors. In this paper it is described the clinical steps of an orthodontic treatment using Incognito™ system, individualized lingual brackets and archwires designed by CAD/CAM technology. Methods: The presented case describes the treatment of a patient with mesofacial growth pattern,Class I malocclusion, with mandibular crowding and diastema between the upper central incisors, treated using 100% individualized lingual brackets. Results: After treatment, the molar relation of Class I was kept, the spaces between upper central incisors were closed and mandibular crowding corrected. Conclusion: This case report demonstrated the efficiency of the new method for lingual orthodontic treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated in vitro the shear bond strength of brackets bonded with xenon plasma arc light, light-emitting diode (LED) and conventional halogen light using different curing times. Brackets were bonded to the buccal surface of 60 human maxillary premolars allocated to five groups. In groups 1 and 2, the resin was cured with the plasma arc for three and six seconds (s), respectively; in groups 3 and 4, the LED was used for five and ten s, respectively; and in group 5, the halogen light was used for 40 s. The specimens were stored in water for 24 hours and subjected to a shear force until bracket failure. The debonding pattern was classified according to the adhesive remnant index (ARI). The results were assessed by Anova and the SNK post-hoc test. No differences were detected among groups 2, 4 and 5, which showed higher averages than groups 1 and 3, which were not different between themselves. The ARI scores showed no differences among the three types of light sources in all times tested. Plasma arc and LED lights can be used with shorter curing times, within certain limits, than conventional halogen light for bonding orthodontic brackets, without decreasing bond strength.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven. Objective: The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket. Material and Methods: Thirty-two bovine incisors crown blocks of 8 mm x 8 mm height lengths were used. Staining of tooth blocks with black tea was performed for six days. They were distributed randomly into 4 groups (1-home bleaching with bracket, 2- home bleaching without bracket, 3- office bleaching with bracket, 4 office bleaching without bracket). The color evaluation was performed (CIE L * a * b *) using color reflectance spectrophotometer. Metal brackets were bonded in groups 1 and 3. The groups 1 and 2 samples were subjected to the carbamide peroxide at 15%, 4 hours daily for 21 days. Groups 3 and 4 were subjected to 3 in-office bleaching treatment sessions, hydrogen peroxide 38%. After removal of the brackets, the second color evaluation was performed in tooth block, difference between the area under the bracket and around it, and after 7 days to verified color stability. Data analysis was performed using the paired t-test and two-way variance analysis and Tukey’s. Results: The home bleaching technique proved to be more effective compared to the office bleaching. There was a significant difference between the margin and center color values of the specimens that were subjected to bracket bonding. Conclusions: The bracket bond presence affected the effectiveness of both the home and office bleaching treatments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To follow the cartographies’ path throughout pernicious (dis)courses of the capitalized Psychology. Com/positions both around desires and binary desires raised from binary norms, followed by (un)folding the beds, the “family”, the clinical thought and practice, the research, the geni(t)ality. Profane writing. Epistemic micro-rebellion promised and incorporated by the ass, because in the beginning it was and it (also) is the ass. A distorted and a trans-barked way of writing by four female dogs looking at Psychology. To (d)enounce the ménage that psychologists, supported by a history without history, intent to build over their empty beds which are blemished by modern Truth(s). Towards a minor psychology, this is a schizo-queer-analytic manifesto on desires-pleasures-senses within the lusophone transcontemporaneity. In the absence of a conclusion, we propose rather the provocative state that only a bitchy-psychology-to-come could edify the visibility of the invisible human. Otherwise, we believe it is in the promising barks that Psychology can be withdrawn from its betraying and betrayed contention of multitudes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to assess the time spent for direct (DBB - direct bracket bonding) and indirect (IBB - indirect bracket bonding) bracket bonding techniques. The time length of laboratorial (IBB) and clinical steps (DBB and IBB) as well as the prevalence of loose bracket after a 24-week follow-up were evaluated. METHODS: Seventeen patients (7 men and 10 women) with a mean age of 21 years, requiring orthodontic treatment were selected for this study. A total of 304 brackets were used (151 DBB and 153 IBB). The same bracket type and bonding material were used in both groups. Data were submitted to statistical analysis by Wilcoxon non-parametric test at 5% level of significance. RESULTS: Considering the total time length, the IBB technique was more time-consuming than the DBB (p < 0.001). However, considering only the clinical phase, the IBB took less time than the DBB (p < 0.001). There was no significant difference (p = 0.910) for the time spent during laboratorial positioning of the brackets and clinical session for IBB in comparison to the clinical procedure for DBB. Additionally, no difference was found as for the prevalence of loose bracket between both groups. CONCLUSION: the IBB can be suggested as a valid clinical procedure since the clinical session was faster and the total time spent for laboratorial positioning of the brackets and clinical procedure was similar to that of DBB. In addition, both approaches resulted in similar frequency of loose bracket.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to assess by means of scanning electron microscopy (SEM) the remaining adhesive interface after debonding orthodontic attachments bonded to bovine teeth with the use of hydrophilic and hydrophobic primers under different dental substrate moisture conditions. MATERIAL AND METHODS: Twenty mandibular incisors were divided into four groups (n=5). In Group I, bracket bonding was performed with Transbond MIP hydrophilic primer and Transbond XT adhesive paste applied to moist substrate, and in Group II a bonding system comprising Transbond XT hydrophobic primer and adhesive paste was applied to moist substrate. Brackets were bonded to the specimens in Groups III and IV using the same adhesive systems, but on dry dental enamel. The images were qualitatively assessed by SEM. RESULTS: The absence of moisture in etched enamel enabled better interaction between bonding materials and the adamantine structure. The hydrophobic primer achieved the worst micromechanical interlocking results when applied to a moist dental structure, whereas the hydrophilic system proved versatile, yielding acceptable results in moist conditions and excellent interaction in the absence of contamination. CONCLUSION: The authors assert that the best condition for the application of primers to dental enamel occurs in the absence of moisture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Higgs bosons can have a substantial invisible branching ratio in many extensions of the Standard Model, such as models where the Higgs bosons decay predominantly into light or massless weakly interacting Goldstone bosons. In this work, we examine the production mechanisms and backgrounds for invisibly decaying Higgs bosons at the Next Linear e+e- Collider operating in the modes e+e-, eγ, and γγ. We demonstrate that such machine is much more efficient to survey for invisibly decaying Higgs bosons than the Large Hadron Collider at CERN.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effects of two conditioning methods used to enhance the shear strength of orthodontic brackets bonded to porcelain surfaces. A total of 18 feldspathic specimens were used. The specimens were divided randomly into two groups (n = 9): group free silane, the porcelain specimens were etched with hidrofuoric acid 10% (Acid Gel-Maquira) for 4 minutes followed by adhesive-primer (Transbond XT) and the metallic brackets (Morelli Roth Light .022" x .030") were bonded with a light-cured microfilled resin (Transbond XT Light Cure Orthodontic Adhesive); group silane, the porcelain specimens were etched with hidrofuoric acid 10% (Acid Gel-Maquira) for 4 minutes followed by silane (Silano Ângelus) for 1 minute, adhesive-primer (Transbond XT) and the metallic brackets (Morelli Roth Light .022" x .030") were bonded with a light-cured microfilled resin (Transbond XT Light Cure Orthodontic Adhesive). All specimens were stored in solution of artificial saliva at ambient temperature for 24 hours. The debonding was done with shear strength through a universal testing machine (DL 500-Emic) calibrated with a fixed speed of 1mm/minute. Statical analysis was performed using the Student t test. The results indicated that in the free silane group the mean bond strength was 9,97 MPA, significantly lower than the silane group, that was 12,38 MPa (p < 0,05). The both groups were effective for bonding, although the silane group had the highest bond strength values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone reconstructions are traditionally conducted with autogenous grafts harvested from intra- or extra-oral donor sites to reestablish the lost bone volume for further implant-prosthetic rehabilitation. The calvarial bone has been studied as an excellent donor site in large atrophic situations, presenting low resorption rates, as well as complications and minimal morbidity. The hospitalization time is short, with low pain levels, short functional limitations, and invisible scars. The skull microarchitecture is predominantly cortical in the presence of growth factors that demonstrate their osteogenic, osteoinductive, and osteoconductive abilities resulting in low resorption rate and high predictability when compared to the iliac crest. Dural lacerations, extra and subdural bleeding, cerebrospinal fluid leakage, and brain damage have been minimized due to the development of surgical technique. The delimitation of diploe, preserving the internal skull cortex before osteotomy at the donor made it possible to reduce accidents and complications. The aim of this paper is to show a technical and to discuss aspects of the use of calvarial bone in the reconstruction of severely atrophic maxilla for oral rehabilitation with osseointegrated implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

How are teachers Cartoons observation Architecture Schools in several decades, the idea was to try and explain firsthand the look and fundamental elements of drawings to the Architect. We start looking through the design of: 1 A projective gaze: the invisible is made visible by interactivity and space and time are perceived by the distance that look place between them; 2nd In bidirectional contamination: the object fills the subject, double-hand, bringing the tactile qualities of architecture in continuous resonance, 3rd Strangeness by slow look: draw as perceptual expansion strategy; 4 Articulation of the structural elements of the design while similar language to architecture and city through the selection of appropriate signs and codes, exclusive and singular.