253 resultados para Fixed Points


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the accuracy of the variables related to the fixed-height stair-climbing test (SCT) using maximal oxygen uptake (V̇O 2 max) as the gold standard. Methods: The SCT was performed on a staircase consisting of 6 flights (72 steps; 12.16 m total height), with verbal encouragement, in 51 patients. Stair-climbing time was measured, the variables 'work' and 'power' also being calculated. The V̇O2 max was measured using ergospirometry according to the Balke protocol. We calculated the Pearson linear correlation (r), as well as the values of p, between the SCT variables and V̇O2 max. To determine accuracy, the V̇O 2 max cut-off point was set at 25 mL/kg/min, and individuals were classified as normal or altered. The cut-off points for the SCT variables were determined using the receiver operating characteristic curve. The Kappa statistic (k) was used in order to assess concordance. Results: The following values were obtained for the variable 'time': cut-off point = 40 s; mean = 41 ± 15.5 s; r = -0.707; p < 0.005; specificity = 89%; sensibility = 83%; accuracy = 86%; and k = 0.724. For 'power', the values obtained were as follows: cut-off point = 200 w; mean = 222.3 ± 95.2 w; r = 0.515; p < 0.005; specificity = 67%; sensibility= 75%; accuracy = 71%; and k = 0.414. Since the correlation between the variable 'work' and V̇O2 max was not significant, that variable was discarded. Conclusion: Of the SCT variables tested, using V̇O2 max as the gold standard, the variable 'time' was the most accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of the brush type as a earner of priming adhesive solutions and the use of paper points as a remover of the excess of these solutions on the push-out bond strength of resin cement to bovine root dentin. The null hypotheses were that brush type and the use of paper points do not affect the bond strength. Materials and Methods: The canals of 80 single-root bovine roots (16 mm in length) were prepared at 12 mm using the preparation drill (FRC Postec Plus, Ivoclar). Half of each root was embedded in acrylic resin and the specimens were divided into 8 groups, considering the factors brush type (4 levels) and paper point (2 levels) (n = 10): Gr 1: small microbrush (Cavi-Tip, SDI); Gr 2: Microbrush (Dentsply); Gr 3: Endobrush (Bisco); Gr 4: conventional brush (Bisco); Gr 5: Cavi-Tip (SDI) + paper points; Gr 6: Microbrush (Dentsply) + paper points; Gr 7: Endobrush (Bisco) + paper points; Gr 8: conventional brush (Bisco) + paper points. The root dentin was treated with a multistep total-etch adhesive system (All Bond 2). The adhesive system was applied using each microbrush, with and without using paper points. One fiber post was molded with addition silicon and 80 posts were made of resin cement (Duolink), The resin posts were luted (Duolink resin cement), and the specimens were stored for 24 h in water at 37°C. Each specimen was cut into 4 disk-shaped samples (1.8 mm in thickness), which were submitted to the push-out test. Results: The brush type (p < 0.0001) (small microbrush > microbrush = endobrush = conventional brush) and the use of paper points (p = 0.0001) (with > without) influenced the bond strength significantly (two-way ANOVA). The null hypotheses were rejected. Conclusion: The smallest brush (Cavi-Tip) and the use of paper points significantly improved the resin bond to bovine root dentin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Swing-by techniques are extensively used in interplanetary missions to minimize fuel consumption and to raise payloads of spaceships. The effectiveness of this type of maneuver has been proven since the beginning of space exploration. According to this premise, we have explored the existence of a natural and direct links between low Earth orbits and the lunar sphere of influence, to obtain low-energy interplanetary trajectories through swing-bys with the Moon and the Earth. The existence of these links are related to a family of retrograde periodic orbits around the Lagrangian equilibrium point L1 predicted for the circular, planar, restricted three-body Earth-Moon-particle problem. The trajectories in these links are sensitive to small disturbances. This enables them to be conveniently diverted reducing so the cost of the swing-by maneuver. These maneuvers allow us a gain in energy sufficient for the trajectories to escape from the Earth-Moon system and to stabilize in heliocentric orbits between the Earth and Venus or Earth and Mars. On the other hand, still within the Earth sphere of influence, and taking advantage of the sensitivity of the trajectories, is possible to design other swing-bys with the Earth or Moon. This allows the trajectories to have larger reach, until they can reach the orbit of other planets as Venus and Mars.(3σ)Broucke, R.A., Periodic Orbits in the Restricted Three-Body Problem with Earth-Moon Masses, JPL Technical Report 32-1168, 1968.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of oral rehabilitation with immediately loaded fixed implant-supported mandibular prostheses on chewing and swallowing in elderly individuals. Materials and Methods: Fifteen completely edentulous patients aged more than 60 years (10 women and rive men), wearing removable dentures in both arches, had a mandibular denture replaced by an implant-supported prosthesis. All individuals were evaluated before surgery and again 3, 6, and 18 months later with regard to mastication and swallowing conditions. Examinations entailed an interview, evaluation of tactile sensitivity of the face, and observation of food intake, masticatory type, formations of bolus, and pain during mastication. The swallowing evaluation comprised observation of clinical signs related to the oral and pharyngeal stages of swallowing, as well as the presence of oral residue. The findings of different evaluations before and 3, 6, and 18 months after the surgical-prosthetic procedure were statistically compared by analysis of variance for repeated measurements at a significance level of 5%. Results: The questionnaire revealed a reduction in complaints of masticatory and swallowing disturbances, a decreased need for liquid ingestion, and reduced choking and coughing. Clinical evaluations showed improved oral function and bolus propulsion for both solid and paste-consistency foods; pain during mastication was also resolved. Conclusion: Treatment with mandibular implant-supported dentures had positive effects on the clinical aspects of mastication and swallowing in elderly individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies on the distribution of plantar pressure between the sole of the foot and the ground were developed before the 19th century. Currently, the most often employed plantar pressure measurement systems are Pedar® and FScan®, which have restrictions such as operational difficulty and high cost. In the present study, a device was constructed from two pressure plates capable of measuring plantar forces in discreet areas of the feet at a low cost, using strain-gages attached to sixteen strategic points of the mechanical elements. Sixteen prismatic beams were soldered to each frame, for which the free extremity of each beam represented a specific point of the foot. Two strain gauges were attached to each beam - one near the upper fixed extremity and the other near the lower fixed extremity. Using a Wheatstone bridge electric circuit, the gauges were used to measure the force acting on the extremity of the beam. Precision and accuracy of the prototype was about 10%. In some measurements, accuracy was 2%. The low precision and accuracy were mainly due to the restrictions of the available equipment, which only permitted four measurements at a time. Thus, it was necessary for participants to stand on the plates four separate times, which signified possible changes in the position of the feet on the pressure plates. Despite some limitations, the aim was achieved. The prototype has been used in some studies and represents a contribution to biomechanics, demonstrating the viability of using strain gauges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to evaluate the effects of plasma progesterone (P4) concentrations and exogenous eCG on ovulation and pregnancy rates of pubertal Nellore heifers in fixed-time artificial insemination (FTAI) protocols. In Experiment 1 (Exp. 1), on Day 0 (7 d after ovulation), heifers (n = 15) were given 2 mg of estradiol benzoate (EB) im and randomly allocated to receive: an intravaginal progesterone-releasing device containing 0.558 g of P4 (group 0.5G, n = 4); an intravaginal device containing 1 g of P4 (group 1G, n = 4); 0.558 g of P4 and PGF2α (PGF; 150 μg d-cloprostenol, group 0.5G/PGF, n = 4); or 1 g of P4 and PGF (group 1G/PGF, n = 3). On Day 8, PGF was given to all heifers and intravaginal devices removed; 24 h later (Day 9), all heifers were given 1 mg EB im. In Exp. 2, pubertal Nellore heifers (n = 292) were treated as in Exp. 1, with FTAI on Day 10 (30 to 36 h after EB). In Exp. 3, pubertal heifers (n = 459) received the treatments described for groups 0.5G/PGF and 1G/PGF and were also given 300 IU of eCG im (groups 0.5G/PGF/eCG and 1G/PGF/eCG) at device removal (Day 8). In Exp. 1, plasma P4 concentrations were significantly higher in heifers that received 1.0 vs 0.588 g P4, and were significantly lower in heifers that received PGF on Day 0. In Exp. 2 and 3, there were no significant differences among groups in rates of ovulation (65-77%) or pregnancy (Exp. 2: 26-33%; Exp. 3: 39-43%). In Exp. 3, diameter of the dominant ovarian follicle on Day 9 was larger in heifers given 0.558 g vs 1.0 g P4 (10.3 ± 0.2 vs 9.3 ± 0.2 mm; P < 0.01). In conclusion, lesser amounts of P4 in the intravaginal device or PGF on Day 0 decreased plasma P4 from Days 1 to 8 and increased diameter of the dominant follicle on Day 9. However, neither of these nor 300 IU of eCG on Day 8 significantly increased rates of ovulation or pregnancy. © 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lagrangian points L4 and L5 lie at 60 degrees ahead of and behind Moon in its orbit with respect to the Earth. Each one of them is a third point of an equilateral triangle with the base of the line defined by those two bodies. These Lagrangian points are stable for the Earth-Moon mass ratio. Because of their distance electromagnetic radiations from the Earth arrive on them substantially attenuated. As so, these Lagrangian points represent remarkable positions to host astronomical observatories. However, this same distance characteristic may be a challenge for periodic servicing mission. In this work, we introduce a new low-cost orbital transfer strategy that opportunistically combine chaotic and swing-by transfers to get a very efficient strategy that can be used for servicing mission on astronomical mission placed on Lagrangian points L4 or L5. This strategy is not only efficient with respect to thrust requirement, but also its time transfer is comparable to others known transfer techniques based on time optimization. Copyright ©2010 by the International Astronautical Federation. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semen cryopreservation is still considered suboptimal due to lower fertility when compared to fresh semen. The reasons for the loss of fertility are various and related to irreversible damage caused to the cells during the freeze-thaw process. An alternative to conventional cryopreservation represents the use of chilled bull semen, preventing the damage associated with freezing, thereby guaranteeing greater sperm viability. The aim of this study was to describe the use of cooled bull semen as a strategy to increase the pregnancy for Fixed-Time Artificial Insemination (FTAI) of Nellore (Bos indicus) cows. One ejaculate of a select Nellore bull obtained by electroejaculation was used; the semen sample was fractioned into two aliquots: one diluted in Botu-Bov® extender containing 6.4% glycerol for cryopreservation (BB-F, frozen group) and one diluted in the same extender, free from cryoprotectants and used for cooling (BB-C, cooled semen group). The samples in the BB-C group were chilled to 5°C using an isothermic box and maintained for 24 h prior to use. A total of 349 lactating Nellore cows (70-90 days after birth) were synchronized by the insertion of a progesterone releasing device (1.0 g) and estradiol benzoate (2.0 mg i.m.) on a random day of the estrous cycle (Day 0); FTAI was performed 44-48 h after the removal of the device. The pregnancy rates were 45.71 and 61.49% (P<0.05), respectively, for the cryopreserved or chilled bovine semen groups. In conclusion, the use of bull semen cooled for 24 h represents an alternative to conventionally cryopreserved semen, as determined by the increase the pregnancy per artificial insemination in bovine herds. © 2012 Science Publication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the safety and efficacy of transitioning patients whose intraocular pressure (IOP) had been insufficiently controlled on prostaglandin analog (PGA) monotherapy to treatment with travoprost 0.004%/timolol 0.5% fixed combination with benzalkonium chloride (TTFC). Methods: This prospective, multicenter, open-label, historical controlled, single-arm study transitioned patients who had primary open-angle glaucoma, pigment dispersion glaucoma, or ocular hypertension and who required further IOP reduction from PGA monotherapy to oncedaily treatment with TTFC for 12 weeks. IOP and safety (adverse events, corrected distance visual acuity, and slit-lamp biomicroscopy) were assessed at baseline, week 4, and week 12. A solicited ocular symptom survey was administered at baseline and at week 12. Patients and investigators reported their medication preference at week 12. Results: Of 65 patients enrolled, 43 had received prior travoprost therapy and 22 had received prior nontravoprost therapy (n = 18, bimatoprost; n = 4, latanoprost). In the total population, mean IOP was significantly reduced from baseline (P = 0.000009), showing a 16.8% reduction after 12 weeks of TTFC therapy. In the study subgroups, mean IOP was significantly reduced from baseline to week 12 (P = 0.0001) in the prior travoprost cohort (19.0% reduction) and in the prior nontravoprost cohort (13.1% reduction). Seven mild, ocular, treatment-related adverse events were reported. Of the ten ocular symptom questions, eight had numerically lower percentages with TTFC compared with prior PGA monotherapy and two had numerically higher percentages with TTFC (dry eye symptoms and ocular stinging/burning). At week 12, TTFC was preferred over prior therapy for 84.2% of patients (48 of 57) by the patients themselves, and for 94.7% of patients (54 of 57) by their physicians. Conclusion: When TTFC replaced PGA monotherapy in patients whose IOP had been uncontrolled, the outcome was a significant reduction in IOP and an acceptable safety and tolerability profile. Most patients and investigators preferred TTFC to prior PGA monotherapy. © 2012 Costa et al, publisher and licensee Dove Medical Press Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An alternative transfer strategy to send spacecrafts to stable orbits around the Lagrangian equilibrium points L4 and L5 based in trajectories derived from the periodic orbits around LI is presented in this work. The trajectories derived, called Trajectories G, are described and studied in terms of the initial generation requirements and their energy variations relative to the Earth through the passage by the lunar sphere of influence. Missions for insertion of spacecrafts in elliptic orbits around L4 and L5 are analysed considering the Restricted Three-Body Problem Earth- Moon-particle and the results are discussed starting from the thrust, time of flight and energy variation relative to the Earth. Copyright© (2012) by the International Astronautical Federation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives were to assess incidence of pregnancy losses, associate this outcome with immunization programs against reproductive diseases, and evaluate the effects of vaccination against bovine herpesvirus-1 (BoHV-1), bovine viral diarrhea virus (BVDV), and Leptospira spp., on reproductive efficiency of Brazilian cow-calf operations. In experiment 1, 7614 lactating Nelore cows from 18 ranches were assigned to the same estrus synchronization and fixed-time AI protocol (ESFTAI; Days -11 to 0). Pregnancy status was determined with transrectal ultrasonography on Days 30 and 120 after AI. Pregnancy loss was deemed to have occurred when cows were pregnant on Day 30 but nonpregnant on Day 120. Incidence of pregnancy loss across all ranches was 4.1%; pregnancy losses were detected (P < 0.10) in 14 ranches but not detected (P > 0.11) in four ranches. Pregnancy loss was lower (P ≤ 0.02) in ranches that vaccinated against BoHV-1, BVDV, and Leptospira spp. compared with ranches that did not vaccinate, or only vaccinated against Leptospira spp. In experiments 2 and 3, lactating Nelore cows (N = 1950 and 2793, respectively) from ranches that did not have a history of vaccinating against reproductive diseases (experiment 2), or only vaccinated against Leptospira spp. (experiment 3), were assigned to the same ESFTAI used in experiment 1. Within each ranch, cows received (VAC) or not (CON) vaccination against BoHV-1, BVDV, and Leptospira spp. at the beginning of the ESFTAI (Day -11) and 30 days after (Day 41) AI. In experiment 2, VAC cows had greater (P ≤ 0.05) pregnancy rates compared with CON on Days 30 and 120. In experiments 2 and 3, pregnancy loss was reduced (P ≤ 0.03) in primiparous VAC cows compared with CON cohorts. In experiment 4, 367 primiparous, lactating Nelore cows previously vaccinated against Leptospira spp. were assigned to the same ESFTAI used in experiment 1. Cows received VAC, or the same vaccine 30 days before (Day -41) and at the beginning (Day -11) of the ESFTAI (PREVAC). Pregnancy rates on Days 30 and 120 were greater (P ≤ 0.05) in PREVAC cows compared with VAC cows. In conclusion, pregnancy losses affected reproductive and overall efficiency of Brazilian cow-calf operations, and might be directly associated with BoHV-1, BVDV, and Leptospira spp. infections. Hence, vaccinating cows against these pathogens, particularly when both doses are administered before fixed-time AI, improved reproductive performance in Brazilian cow-calf systems. © 2013 Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is known that several factors can affect the clinical success and durability of fixed partial dentures. Therefore, the aim of the present study was to present a literature review about the longevity, clinical success, and quality, as well as, patients' and dental surgeons' satisfaction of ceramic fixed dentures. High rate of patients' satisfaction has been observed in relation to the esthetic of ceramic crowns. In addition, the literature has shown that dental ceramics can be used in several clinical situations with high success rate and longevity. Despite of failures and complications of ceramic restorations, nowadays, with the improvement of mechanical properties of such materials, ceramic crowns present a favorable prognosis and can be used in several clinical situations with high success rate, clinical quality, and great patients' satisfaction. © 2013 The American Ceramic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.