222 resultados para Exponential power distribution
Resumo:
A constructive heuristic algorithm (CHA) to solve distribution system planning (DSP) problem is presented. The DSP is a very complex mixed binary nonlinear programming problem. A CHA is aimed at obtaining an excellent quality solution for the DSP problem. However, a local improvement phase and a branching technique were implemented in the CHA to improve its solution. In each step of the CHA, a sensitivity index is used to add a circuit or a substation to the distribution system. This sensitivity index is obtained by solving the DSP problem considering the numbers of circuits and substations to be added as continuous variables (relaxed problem). The relaxed problem is a large and complex nonlinear programming and was solved through an efficient nonlinear optimization solver. Results of two tests systems and one real distribution system are presented in this paper in order to show the ability of the proposed algorithm.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Energy policies and technological progress in the development of wind turbines have made wind power the fastest growing renewable power source worldwide. The inherent variability of this resource requires special attention when analyzing the impacts of high penetration on the distribution network. A time-series steady-state analysis is proposed that assesses technical issues such as energy export, losses, and short-circuit levels. A multiobjective programming approach based on the nondominated sorting genetic algorithm (NSGA) is applied in order to find configurations that maximize the integration of distributed wind power generation (DWPG) while satisfying voltage and thermal limits. The approach has been applied to a medium voltage distribution network considering hourly demand and wind profiles for part of the U.K. The Pareto optimal solutions obtained highlight the drawbacks of using a single demand and generation scenario, and indicate the importance of appropriate substation voltage settings for maximizing the connection of MPG.
Resumo:
An efficient heuristic algorithm is presented in this work in order to solve the optimal capacitor placement problem in radial distribution systems. The proposal uses the solution from the mathematical model after relaxing the integrality of the discrete variables as a strategy to identify the most attractive bus to add capacitors to each step of the heuristic algorithm. The relaxed mathematical model is a nonlinear programming problem and is solved using a specialized interior point method, The algorithm still incorporates an additional strategy of local search that enables the finding of a group of quality solutions after small alterations in the optimization strategy. Proposed solution methodology has been implemented and tested in known electric systems getting a satisfactory outcome compared with metaheuristic methods.The tests carried out in electric systems known in specialized literature reveal the satisfactory outcome of the proposed algorithm compared with metaheuristic methods. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
In this paper an efficient algorithm for probabilistic analysis of unbalanced three-phase weakly-meshed distribution systems is presented. This algorithm uses the technique of Two-Point Estimate Method for calculating the probabilistic behavior of the system random variables. Additionally, the deterministic analysis of the state variables is performed by means of a Compensation-Based Radial Load Flow (CBRLF). Such load flow efficiently exploits the topological characteristics of the network. To deal with distributed generation, a strategy to incorporate a simplified model of a generator in the CBRLF is proposed. Thus, depending on the type of control and generator operation conditions, the node with distributed generation can be modeled either as a PV or PQ node. To validate the efficiency of the proposed algorithm, the IEEE 37 bus test system is used. The probabilistic results are compared with those obtained using the Monte Carlo method.
Resumo:
Evaluate the distribution and variation of placental vascular indices according to gestational age and placental volume. From March to November 2007, three-dimensional (3D)-power Doppler ultrasound was performed in 295 normal pregnancies from 12 to 40 weeks of gestation. Using the same preestablished settings for all patients, power Doppler was applied to the placenta and placental Volume was obtained by the rotational technique (VOCAL(TM)). The 3D-power histogram was used to determine the placental vascular indices: vascularization index (VI), flow index (FI) and vascularization-flow index (VFI). The placental vascular indices were then plotted against gestational age and placental volume. All placental vascular indices showed constant distribution throughout gestation. A tendency for a reduction in placental vascular indices with increased placental volume was observed, but was only statistically significant when placental FI was considered (p < 0.05). All placental vascular indices estimated by 3D-power Doppler ultrasonography presented constant distribution throughout gestation, despite the increase in placental volume according to gestational age. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The number of citations of a scientific publication or of an individual scientist has become an important factor of quality assessment in science. We report a study of the statistical distribution of the citation index of both scientific publications and scientists. We give numerical evidence that Tsallis (power law) statistics explains the entire distribution over eight orders of magnitude (10-4 to 10(4)). Also, we draw Zipf plots in order to analyze the statistical distribution of the citation index of Brazilian and international physicists and chemists. The relatively small group of Brazilian scientists seems more adequate to explain the dynamics of the citation index. In this case, we find that the distribution of the citation index can also be explained by a gradually truncated power law with similar parameters. We finally discuss possible mechanisms behind the citation index of scientists and scientific publications.
Resumo:
Este estudo é parte do monitoramento limnológico empreendido pela Companhia Energética do Estado de São Paulo (CESP) durante o processo de enchimento do reservatório de Porto Primavera (Usina Hidrelétrica Engenheiro Sérgio Motta). Este reservatório, localizado no alto rio Paraná, entre os Estados de São Paulo e Mato Grosso, é o quarto maior do país. A primeira etapa de enchimento do lago começou em dezembro de 1998 e a segunda em março de 2001. Amostras para a análise da comunidade bentônica e das características sedimentológicas foram coletadas trimestralmente entre agosto de 1999 e novembro de 2001 e também em agosto de 2002 (11 campanhas). As coletas foram feitas em 13 estações de amostragem distribuídas no reservatório e em uma localizada a jusante da barragem. 128 táxons de invertebrados foram encontrados, sendo Mollusca, Annelida, Insecta e Nematoda os grupos dominantes durante praticamente todos os meses analisados. A classe Insecta foi a melhor representada, com 9 diferentes ordens, dentro das quais os Diptera contribuíram com a ocorrência de 63 táxons. A espécie exótica de bivalve Corbicula fluminea foi registrada em todas as estações de amostragem mostrando sua grande capacidade para colonizar novos habitats em regiões neotropicais. Variações consideráveis na densidade da fauna foram observadas para os diferentes períodos e locais analisados. A densidade máxima (média de 7812 ind.m-2) foi registrada no centro do reservatório enquanto que as densidades mínimas foram registradas na zona lacustre próxima à barragem (média de 9 ind.m-2). A maior riqueza de espécies por local/período (24 táxons) foi encontrada no trecho superior do reservatório (trecho fluvial). A diversidade máxima foi observada nas zonas superior e central do reservatório, com valores de 3.82 e 3.86 (bits.ind-1) no início (agosto/1999) e final (agosto/2002) do processo de enchimento, respectivamente. Não foi encontrado um padrão de distribuição dos grupos faunísticos que pudesse estar associado com a textura granulométrica dos diferentes locais amostrados. Por outro lado, constatou-se a diminuição, ou mesmo a não ocorrência de organismos, nas estações com elevada concentração de matéria orgânica (>40%) em baixo estado de degradação (grandes detritos vegetais). Tal fato pode estar relacionado com a falta de depósitos de sedimentos, dificultando a fixação de organismos da fauna bentônica, bem como com condições químicas mais redutoras em função da intensidade dos processos de decomposição da fitomassa inundada.
Resumo:
The neutral wire in most existing power flow and fault analysis software is usually merged into phase wires using Kron's reduction method. In some applications, such as fault analysis, fault location, power quality studies, safety analysis, loss analysis etc., knowledge of the neutral wire and ground currents and voltages could be of particular interest. A general short-circuit analysis algorithm for three-phase four-wire distribution networks, based on the hybrid compensation method, is presented. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. A generalised fault analysis method is applied to the distribution network for conditions with and without embedded generation. Results obtained from several case studies on medium- and low-voltage test networks with unbalanced loads, for isolated and multi-grounded neutral scenarios, are presented and discussed. Simulation results show the effects of neutrals and system grounding on the operation of the distribution feeders.
Resumo:
An optimisation technique to solve transmission network expansion planning problem, using the AC model, is presented. This is a very complex mixed integer nonlinear programming problem. A constructive heuristic algorithm aimed at obtaining an excellent quality solution for this problem is presented. An interior point method is employed to solve nonlinear programming problems during the solution steps of the algorithm. Results of the tests, carried out with three electrical energy systems, show the capabilities of the method and also the viability of using the AC model to solve the problem.
Resumo:
Power-law distributions have been observed in various economical and physical systems. Levy flights have infinite variance which discourage a physical approach. We introduce a class of stochastic processes, the gradually truncated Levy flight in which large steps of a Levy flight are gradually eliminated. It has finite variance and the system can be analyzed in a closed form. We applied the present method to explain the distribution of a particular economical index. The present method can be applied to describe time series in a variety of fields, i.e. turbulent flow, anomalous diffusion, polymers, etc. (C) 1999 Elsevier B.V. B.V. All rights reserved.