179 resultados para Electric torque
Resumo:
Whereas the assembly torque calculation has great importance on efficiency and life of bolts, the objective of this study was to analyze the combined stresses during assembly, the friction coefficient, compare the rupture torque results with the indicated torques by standards and to present a new torque method without the stress combination (shear stress and normal stresses). For this study were carried eighteen tests with different diameters and materials, this bolts were undergoing five ranges torque until the breaking torque. With the experimental rupture torque values for each test and with the bolt quality certificate was possible to calculate the friction coefficient so compared with the theory. Another comparison was the experimental rupture torque with assembly torque indicated by NBR-8800 and ASME-PCC. The main conclusion are related to combined stress, because for this factor can fail at the assembly time, so for in some cases must use the tensioning method, because in this method won't be present torsional stresses
Resumo:
This work aims to kinematic and dynamic analysis of a VW Saveiro in order to estimate the power requested to the engine with the imposed movement conditions. Thus, the study will be the basis to the specification of the electric engine, on the conversion of the internal combustion vehicle into electric one. First of all, a literature review was done in order to understand the state of the art for this issue and come up with the technical features of the vehicle in question. The next step is the identification and calculation of all forces acting on the prototype in motion, from 0 to 120 km/h, in intervals of 10 km/h, under the defined conditions of path and time. Then, were determined the values of the torque and rotation of the components from the transmission system, as well as the engine power, for each speed range. The results show the most influential forces on the resistence of the movement in each speed range, and the behavior of the torque curve is verified. Finally, it was also analyzed the implementation of pinwheels on the frontal area of the vehicle, in order to convert wind energy into electrical energy to supply the lighting subsystem of the vehicle and the proposal was validated. Limiting the maximum speed of the vehicle to 90 km/h, it was finally concluded that the power of the electric engine should be 40 HP
Resumo:
Introdução – Uma das causas mais prováveis de lesões esportivas está relacionada aos desequilíbrios musculares e a fadiga muscular, que é evidenciada no decorrer de um jogo de futebol, principalmente no final do jogo. Esta pode ser avaliada através da comparação da força de contração máxima antes e após o exercício. A fadiga produzida durante o jogo diminui a força muscular concêntrica e excêntrica de flexores e extensores do joelho podendo aumentar a incidência de lesões. Objetivo - Avaliar o efeito de uma partida sobre o pico de torque funcional e convencional nos músculos isquiotibiais e quadríceps de jogadores de futebol de salão com e sem desequilíbrio muscular. Método – Oito jogadores de futebol de salão do gênero masculino, com idade entre 18 e 24 anos, fizeram três visitas ao laboratório: 1ª foram realizadas a antropometria e adaptação aos equipamentos; 2ª teste máximo no dinamômetro isocinético para determinar a razão do pico de torque funcional e convencional nos músculos isquiotibiais e quadríceps; 3ª idem ao 2ª, após a partida de futebol de salão. Análise estatística – através das médias ± DP dos dados obtidos foi utilizado o teste t para amostras dependentes e o Mann Whitney para comparação do pico de torque antes e após a partida de futebol de salão e para comparação da relação flexor/extensor pré e pós- esforço, respectivamente. Em ambos os testes foram adotado um nível de significância de p < 0,05. Resultados - Não foram encontradas diferenças significantes entre os grupos de atletas com desequilíbrio muscular na perna dominante (GD) e grupo equilíbrio (GE) e para os extensores e flexores do GD e GE nas condições Con60. Através do Mann Whitney foram encontradas diferenças...(Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
Introdução: A lesão mais comumente encontrada na população ativa é a entorse de tornozelo. Cerca de 40% destes casos continuam a manifestar sensação de instabilidade articular mesmo após a fase aguda da lesão, caracterizando a instabilidade funcional do tornozelo (IFT). A IFT está relacionada com déficits proprioceptivos e redução na capacidade de produção de força e potência muscular. Haja vista que o basquetebol é um esporte com grande incidência de lesões no tornozelo faz-se necessário o entendimento de métodos de avaliação de baixo custo, que possam contribuir para a prevenção deste tipo de lesão em atletas. Objetivo: Nesse sentido, o presente estudo, tem como objetivo identificar os parâmetros de torque, atividade eletromiográfica, senso de reposicionamento articular e a pontuação em teste funcional em jogadoras de basquetebol com tornozelo estável. Correlacionar os valores de torque, atividade eletromiográfica e do senso de reposionamento articular com a pontuação dos testes funcionais em individuos saudáveis. Método: Participaram deste estudo 6 atletas do gênero feminino praticantes do basquetebol com idade entre 18 e 25 anos. As voluntárias realizaram os seguintes testes: torque isocinético concêntrico em inversão (INV) e eversão (EVE) nas velocidades de 60º e 120º, cinco testes funcionais e teste de reposicionamento articular com os ângulos-alvo de 10º e 20º de inversão. Após a verificação da normalidade de distribuição dos dados com o teste Shapiro-Wilk, utilizou-se o teste de Correlação Spearman para verificar a correlação dos testes funcionais com o pico de torque, o sinal EMG e o reposicionamento articular. Resultados: Não foi encontrados resultados esperados no estudo, exceto na correlação negativa para os valores de RMS do TA na velocidade de 120º nas contrações isocinética...(Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
A natação é um esporte praticado em meio líquido o que a torna muito dependente da técnica do nadador, pelo fato de apresentar maior resistência quando comparado com o meio terrestre. A força muscular, composição corporal e a técnica do nado são alguns fatores determinantes para a melhora do desempenho esportivo do atleta. Sendo assim, a capacidade de gerar força propulsiva e minimizar a resistência ao meio líquido são altamente influenciadoras do desempenho nesta modalidade. Um dos principais músculos utilizados na propulsão da braçada do nado crawl é o tríceps braquial o qual é responsável pela extensão do cotovelo. O nível de força dos membros dominante e não dominante também pode influenciar no desequilíbrio muscular dos nadadores e consequentemente na propulsão do atleta. Sendo assim, o objetivo deste estudo foi analisar a reprodutibilidade de pico de torque (PT) durante as contrações isométrica e isocinética concêntrica em diferentes velocidades do músculo tríceps braquial nos membros dominante e não dominante em nadadores. Participaram do estudo nadadores velocistas e meio fundistas do gênero masculino, com idade entre 18 e 28 anos, com experiência no mínimo de 3 anos na modalidade. Os voluntários foram solicitados a comparecer no laboratório em 3 ocasiões em dias diferentes. Primeiramente para obter as medidas antropométricas (massa, estatura, envergadura e dobras cutâneas) e logo em seguida foi feita a familiarização ao teste isométrico e isocinético no dinamômetro. Nas próximas visitas os atletas realizaram no dinamômetro isocinético, o teste máximo para determinação do PT da contração isométrica e isocinéticas concêntricas em diferentes velocidades. O procedimento foi realizado duas vezes em dias diferentes. O teste para determinação do PT isométrico e isocinético foi realizado de forma aleatória... (Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
The objective of this study was to investigate the influence of previous active static stretch on the isometric peak torque (PT) and rate of force development (RFD) measured from different time intervals from the beginning of muscle contraction. Participated of this study 15 male individuals, apparently healthy, with ages between 18 and 25 years, without regular physical activity practice. The individuals were submitted in different days to the following tests: 1) Familiarization session to the isokinetic dynamometer; 2) Two maximal isometric concentric contractions for knee extensors in isokinetic dynamometer to determine PT and RFD (Control), and; 3) Two active static stretching exercises for the dominant leg extensors (10 x 30 s for each exercise, with 20 s of rest). After the stretching, the isokinetic test was repeated (Post-Stretching). The conditions 2 and 3 were performed in random order. The RFD was considered as the mean slope of the moment-time curve at time intervals of 0-30, 0-50 and 0-100ms relative to the beginning of muscle contraction. It was verified significant reduction for both maximal RFD and PT after the stretching (p < 0.05). At intervals of 0- 30ms, 0-50ms and 0-100ms, the RFD at the conditions with stretching was similar to the RFD without stretching (p > 0.05). At intervals of 0-150ms and 0-200ms, the RFD obtained at the contraction without stretching was significantly higher that that obtained at the contraction with stretching (p < 0.05). It can be concluded that the static stretching, performed with duration of 600 s diminish isometric PT, maximal RFD and RFD measured at late phase (> 100 ms) of muscle contraction.
Resumo:
The objective of this study was to investigate the influence of previous active static stretch on the peak torque (PT) and rate of force development (TDF) during isokinetic concentric contractions at 60 and 180.s-1 in active individuals. Twelve active subjects with ages between 18 and 30 years participated of this study. The individuals were submitted in different days to the following tests: 1) Familiarization session to the isokinetic dynamometer; 2) Five maximal isokinetic concentric contractions for knee extensors at each angular velocity (60 and 180.s-1) to determine PT and TDF (Control), and; 3) Two active static stretching exercises for the dominant leg extensors (10 x 30 s for each exercise, with 20 s of rest). After the stretching, the isokinetic test was repeated (Post-Stretching). The conditions 2 and 3 were performed in random order. There was no significant modification after the stretch exercises on the PT, angle and time at which the PT was attained, at 60 and 180º.s-1. In the same way, there was no significant modification on the TDF and angle at which the maximal TDF was attained in both angular speeds. In other way, the time to attain maximal TDF (TTDF) at 180º.s-1 was significantly lower after the stretching (Pre - 98.3 ± 27.5 ms and Post - 86.6 ± 30.2 ms). There was significant modification on the torque (60 and 180º.s-1) and time (60º.s-1) at different delta of angle variations, obtained at 60º.s-1 at Control and Post-Stretching conditions. However, there was significant reduction of time after the stretching exercises on delta of angle variations of 90-88º (Pre - 46.6 ± 6.5 ms and Post - 44.1 ± 5.1 ms), 88-85º (Pre - 65.8 ± 7.9 ms and Post - 63.3 ± 4.9 ms) and 85-80º (Pre - 93.3 ± 7.7 ms and Post - 90.0 ± 4.2 ms) at 180º.s-1. With base on these data, it is possible to conclude that PT and TDF do not modify after static stretching, irrespectively on the speed...(Complete abstract click electronic access below)
Resumo:
Indoor soccer is a modality of sport similar to football, which is accompanying an increasing of the number of participants. With the growth of this sport, increased as well the number of injuries, which has been requiring greater attention and care from the health professionals. AIMS: To investigate the functional balance before and after an indoor soccer game and analyze the maximum force before and after the game, in order to verify if there is a great loss of muscle strength of knee flexors and extensors during the game. METHODS: The study included seven amateur soccer players. The isokinetic evaluation was made using the Biodex 3 isokinetic dynamometer at velocities of 60°/s and 180°/s with five repetitions at each velocity for each leg. Further, the study analyzed the peak torque of each leg at each speed of the extensor muscles and flexor concentric and eccentric. RESULTS: Compared to the peak torque before and after the game, there were no significant differences. At 60°/s in the non-dominant leg, peak torque decreased after the game of the extensor concentric and eccentric. In the dominant leg there was a decrease of peak torque in eccentric flexion at 60°/s and concentric flexion to 180°/s. Comparing the peak torque between dominance, there was any significant differences in speed. However, in eccentric flexion at 60°/s before the match there was a significant difference. The peak torque of the dominant leg showed better results than the non-dominant leg. Regarding the functional balance there was no statistically significant differences between the muscles involved. CONCLUSION: From the results achieved, it is possible to conclude that the peak torque of flexor eccentric decreases depending on the length of the exercise. This muscle is stronger in the dominant leg, comparing to the non-dominant leg
Resumo:
The present work shows a coupling of electrical and gravitational fields through Cauchy-Riemann conditions for quaternions present in a previous paper [1]. It is also obtained an extended version of the Laplace-like equations for quaternions, now written in terms of both electric and gravitational fields.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this paper, to solve the reconfiguration problem of radial distribution systems a scatter search, which is a metaheuristic-based algorithm, is proposed. In the codification process of this algorithm a structure called node-depth representation is used. It then, via the operators and from the electrical power system point of view, results finding only radial topologies. In order to show the effectiveness, usefulness, and the efficiency of the proposed method, a commonly used test system, 135-bus, and a practical system, a part of Sao Paulo state's distribution network, 7052 bus, are conducted. Results confirm the efficiency of the proposed algorithm that can find high quality solutions satisfying all the physical and operational constraints of the problem.