163 resultados para Distribuição de energia
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Electrical energy is present in the lives of all people and is extremely important that it be delivered to end users with plenty of quality, safety and low costs. The electric power substations are responsible for transmission and distribution of electricity generating sources to consumers, and with technological advances and the subsequent automation of same, the electricity began to be delivered with greater continuity and reliability. Protection systems in substations are largely responsible for making the electricity reaches the final consumer with quality, since their function is to prevent the spread of any type of failure occurred at any point of transmission to the load centers. These systems consist primarily by the current transformers and potential, by the protective relays and circuit breakers and switchgear. The processors send the necessary data to the relays and, if those detect any abnormality in the system, operate the opening command of the branch circuit breakers to isolate where the fault. Therefore, it is essential to better understand the operation of such equipment, as well as the overall system. This work aims to study the main substation equipment, current transformers and potential and, especially, protection relays, in order to obtain the advantages that automated systems can provide
Resumo:
Nuclear medicine uses non-sealed sources for exams and treatments, because the movement of these sources, source of patients injected or not, involve a wide range of environmental radiometric levels. To better control of these levels this study was aimed at monitoring points strategically distributed in all environments Sector Technical Nuclear Medicine, Hospital of the Botucatu Medical School, performing two measurements at random times daily for a period of three months, sampling the normal routine of the sector. The detector Geiger-Muller was used for the acquisition of exposure rates of the points, efficiency and reprodutibility test have shown good performance of this equipment for this purpose. The results allowed to make a projection of annual dose for each environment indicating higher risks for Occupationally Exposed Individuals as well as Public Individuals compared with the limits established by the National Commission of Nuclear Energy. Was developed a spatial map of dose that can be used as a visual warning to the regions with the highest exposure to ionizing radiation, enabling reduced risk of a potential exposure
Resumo:
How companies can sell their surplus production capacity of electric power in Brazil? This work was developed from the question presented and focusing on clarification of procedures to enter the Brazilian electricity market by providing basic guidelines based on resolutions by National Agency of Electric Energy, National System Operator procedures and rules of the Assembly of Electric Energy Commercialization. It features subsidy to companies that fit this profile to evaluate the possibility to sell their surplus electricity. The general aim was to analyze the procedures and the necessary steps to make this sale happen. Was developed through a literature review where an overview of the Brazilian electric sector and a case study of a company that has excess capacity of electricity, but doesn’t make its marketing. Resulted in the expected clarification as well as the incentive for companies through the information presented, the entry in this trade since power is still crucial to the country's economic growth and ensure its availability in quantity demanded is a challenge of the utmost importance for satisfactory results are achieved economic development contributing to the progress of our society
Resumo:
A energia solar fotovoltaica tem se destacado como uma opção de fonte energética limpa e muito confiável. No entanto, é a Europa que detém a maior representatividade fotovoltaica no mercado mundial, indo contra o senso comum de que seriam os países pertencentes ao Cinturão do Sol aqueles com a maior capacidade instalada. Apesar das condições favoráveis para o desenvolvimento da fonte, o Brasil possui um mercado muito deficitário, contando apenas com poucos projetos de incentivo para levar eletricidade para comunidades carentes afastadas dos centros de geração ou das redes de distribuição. O país carece de programas exclusivos para a energia solar fotovoltaica que proporcionem incentivos ao mercado, a fim de impulsionar a indústria local e estimular o investimento no longo prazo para a maior diversificação da matriz energética brasileira. Assim, o presente estudo buscou ilustrar e analisar o cenário do mercado brasileiro atual da energia solar fotovoltaica, apresentando seus saldos comerciais com os quatro principais mercados mundiais para a fonte: Europa, EUA, Japão e China, segundo os dados disponibilizados pelo banco de dados Aliceweb para os itens 8541401, 8541402 e 8541403, classificados segundo a NCM
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Distribution networks are formed by long lines that carry electricity substations to homes and industries. These lines have associated impedance and depending on operating conditions of the network these impedances may vary. This paper provides a detailed analysis of the effects observed in studies of voltage drop, short circuit and electrical losses, when considered the drivers sequence impedances used in primary distribution network at different temperatures. Therefore, it is initially presented a calculation methodology and details the factors that influence the final values. The methodology presented tackles in a practical way the main factors that directly or indirectly influence the values of the impedances as an emblematic example and will be properly dealt with throughout the paper is the effect of temperature on the values of the sequence impedances. More specifically is dealt with the case of XLPE cables protected, by having a higher maximum operating temperature than the operating temperature of the network. The effects observed in the power flow generated when considering the impedance values at both temperatures were analyzed. The impedance drivers tend to increase with increasing temperature. Thus the impedance of the conductor XLPE protected will tend to be greater for the maximum operating temperature for which the operating temperature of the network, resulting in greater voltage drop and higher electrical losses
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)