444 resultados para CFU


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This pilot study evaluated, by culture testing, the effectiveness of lethal photosensitization for the microbiological treatment of peri-implantitis in dogs. Experimental peri-implantitis was induced by ligature placement for 2 months. Following ligature removal, plaque control was instituted by scrubbing with 0.12% chlorhexidine daily for 12 months. Subsequently, mucoperiosteal flaps were elevated for scaling the implant surface. Microbial samples were obtained with paper points before and after treatment of implant surfaces by means of 100 microg/ml toluidine blue O (TBO,) and were exposed, for 80 s, to light with a wavelength of 685 nm from a 50 mW GaAlAs diode laser. The mean initial and final bacterial counts were 7.22 +/- 0.20 and 6.84 +/- 0.44 CFU/ml, respectively for TVC (P < 0.0001); 6.19 +/- 0.45 and 3.14 +/- 3.29 CFU/ml for P. intermedia/nigrescens (P = 0.001); 5.98 +/- 0.38 and 1.69 +/- 2.90 CFU/ml for Fusobacterium spp. (P = 0.001); and 6.07 +/- 0.22 to 1.69 +/- 2.94 CFU/ml for beta-hemolytic Streptococcus (P = 0.0039). It may be concluded that lethal photosensitization resulted in a reduction of the bacterial count. Complete elimination of bacteria was achieved in some samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effectiveness of microwave irradiation sterilization on hard chairside reline resins. Materials and Methods: Specimens of three reline resins (Kooliner, Tokuso Rebase, and Ufi Gel Hard) were fabricated and subjected to ethylene oxide sterilization. The specimens were then individually inoculated (107 cfu/mL) with Tryptic Soy Broth media containing one of the tested microorganisms (C albicans, S aureus, B subtilis, and P aeruginosa). After 48 hours at 37°C, the samples were vortexed for 1 minute and allowed to stand for 9 minutes, followed by a short vortex to resuspend any organisms present. After inoculation, 40 specimens of each material were immersed in 200 mL of water and subjected to microwave irradiation at 650 W for 6 minutes. Forty non-irradiated specimens were used as positive controls. Replicate specimens (25 μL) of suspension were plated at dilutions of 10-3 to 10-6 on plates of selective media appropriate for each organism. All plates were incubated at 37°C for 48 hours. After incubation, colonies were counted, and the data were statistically analyzed by the Kruskal-Wallis test. Twelve specimens of each material were prepared for SEM. Results: All immersed specimens showed consistent sterilization of all the individual organisms after microwave irradiation. SEM examination indicated an alteration in cell morphology after microwave irradiation. Conclusion: Microwave sterilization for 6 minutes at 650 W proved to be effective for the sterilization of hard chairside reline resins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of metal bioleaching on nutrient solubilization, especially nitrogen and phosphorous, from anaerobically-digested sewage sludge were investigated in this work. The assessment of the sanitary quality of the anaerobic sludge after bioleaching was also carried out by enumerating indicator (total coliforms, fecal coliforms, and fecal streptococci) and total heterotrophic bacteria. The experiments of bioleaching were performed using indigenous sulphur-oxidizing bacteria (Thiobacillus spp.) as inoculum and samples of anaerobically-digested sludge. Nitrogen and phosphorous solubilization from sewage sludge was assessed by measuring, respectively, the concentration of Total Kjeldahl Nitrogen, ammonia, nitrate/nitrite, and soluble and total phosphorous before and after the bioleaching assays. At the end of the experiment, after 4 days of incubation (final pH of 1.4), the following metal solubilization yields were obtained: zinc, 91%; nickel, 87%; copper, 79%; lead, 52%; and chromium, 42%. As a result of sludge acidification, the viable counts of selected indicator bacteria were decreased to below the detection limit (4 × 103 cfu 100 ml-1), followed by an increase in the mineral fraction of nitrogen (from 6 to 10%) and in the soluble fraction of phosphorous (from 15 to 30%). Although some loss of sludge nutrients can occur during solid-liquid separation following bioleaching, its beneficial effects as metal removal and reduction of pathogenic bacteria are sufficient to consider the potential of this treatment before sludge disposal onto agricultural fields.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To assess the potential for contamination of wastewaters from pig farming. Methods. Wastewaters from pig farming were stored in a tank. After 0, 30, 60, 90, and 120 days of hydraulic retention, they were added to lysimeters filled with argillaceous, sandy, or medium soil. Finally, these lysimeters were submitted to simulations of either a rainy season or a dry season. The number of colony-forming units (CFUs) of total coliforms, fecal coliforms, and fecal streptococci was measured in the effluents of the storage tank (for the various periods of hydraulic retention), in the percolate from the lysimeters, and in the three types of soil. The microbiological analyses were carried out using the membrane filter technique. The pH analyses were done potentiometrically. Results. For the three microorganisms, the largest decrease in bacterial counts in the storage tanks occurred with 90 or 120 days of retention. There was a marked decrease in the bacterial count in the percolates of the three soils. For the three soil types the greatest reduction in bacterial counts was found in medium soil, due to its acidity (pH < 7.0). Hydraulic retention was not sufficient to ensure the sanitary adequacy of the wastewaters and their use for irrigation, given that fecal coliform values were above 1 000 CFU per 100 mL. Therefore, adding the residues to the soil was considered a second stage of treatment. Conclusions. The retention of wastewaters followed by adding them to soil was effective in minimizing the contaminating effect of pig farming residues. The storage time for wastewaters from pig farming could be decreased from 120 to 90 days.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Essential oils were obtained from fennel seeds, dill, cumin and coriander. Their antimicrobial activity was tested on isolated clinical specimens of patients treated at the University Hospital of the School of Medicine of Botucatu, SP, UNESP. Microorganisms were grown in BHI (Brain Heart Infusion/Oxoid) at 37oC/18 hours and resuspended in 0,5 Mac Farland's Standard (1,5 x 108 CFU/mL). The diffusion method was performed, putting 10 μl of the essential oils on paper disks (6mm of diameter) (Blank Disks/CECON) at 37oC/24 hours. After this period, the disks were put on plates containing Mueller Hinton Agar (Oxoid) and inoculated with the microorganisms. After 48 hours at 37oC, inhibitory zones were measured (mm) for the respective oils and strains. The essential oil from Anethum graveolens showed antimicrobial activity against Staphylococcus aureus (inhibitory zone=18 mm), Salmonella sp. (=11 mm) and E. coli (10 mm). The Cuminum cyminum essential oil was effective against E. coli, P. aeruginosa and Salmonella sp. and their inhibitory zones were 18, 10 and 23 mm, respectively. Coriandrum sativum oil was active only against Salmonella sp. (18 mm) and Foeniculum vulgare inhibited only E. coli (9 mm).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to observe the prevalence of Candida spp. in the oral cavity of children undergoing treatment with inhaled corticosteroids. Thirty children treated with inhaled corticosteroids and thirty control children were studied. Saliva samples were collected through oral rinses with phosphate buffered saline (PBS). The samples were plated on Sabouraud's dextrose agar and incubated at 37 degrees C for 48 h. After this period, the number of colony-forming units per ml (cfu/ml) of saliva was calculated. The isolates were identified by phenotypic characterization. Candida spp. was isolated from 43.33% of the samples of children treated with corticosteroids, with a mean of 780 cfu/ml of saliva, and from 30% of the samples of the control group, with a mean of 560 cfu/ml of saliva. No significant statistical difference was observed between the groups. C. albicans was the prevalent species in both groups, followed by C. guilliermondii, C. parapsilosis and C. stellatoidea. Furthermore, Rhodotorula rubra and C. lusitaniae were also isolated from the treated group. We concluded that there was no significant increase in the prevalence and number of Candida spp. in the oral cavity of children treated with inhaled corticosteroids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Patients with fixed orthodontic appliances often experience an absolute increase in the number of Streptococci mutans colony-forming units (cfu). The aim of this investigation was to study the development of biofilm and S. mutans cfu in connection with stainless steel ligatures and elastomeric rings in orthodontic patients treated with and without 0.4% stannous fluoride gel (SFG). Material: Forty-seven patients were divided into 2 groups: those treated with 0.4% SFG for 4 minutes (experimental) and those without 0.4% SFG (control). In each patient, elastomeric rings were used for ligation on 1 side of the dental arch midline, and stainless steel ligatures were used on the opposite side. Saliva samples were collected before and after appliance placement. At 15 and 30 days after appliance placement, biofilm samples from the stainless steel ligatures and the elastomeric rings were collected and subjected to microbiologic procedures and scanning electron microscopy (SEM) analysis. Results: The numbers of S. mutans cfu in the saliva and biofilm were not statistically different between the teeth fitted with elastomeric rings and stainless steel ligatures, or between the experimental and control groups. SEM analysis showed biofilm formation on both ligature ties. Conclusions: Topical application of 0.4% SFG in orthodontic patients with elastomeric rings or stainless steel ligatures does not cause a significant decrease in S. mutans cfu in the saliva and biofilm. Copyright © 2005 by the American Association of Orthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate in vitro the antimicrobial activity of glass ionomer (GIC) and zinc oxide-eugenol (ZOE) cements against Candida albicans. Standardized GIC and ZOE specimens were maintained in contact with C. albicans suspension (1 x 10(6) cells/ml) at 37 degrees C for 24 h, 48 h or 7 days. A control group without any testing cement was included. After the incubation period, aliquots of 0.1 ml were plated on Sabouraud's agar, and then the number of colonies was counted. The results were expressed as values of logarithms of colony-forming units per milliliter (log CFU/mL) and were analyzed statistically by Kruskal-Wallis ANOVA. After 48 h of incubation, the ZOE group presented no growth of C. albicans. GIC and control groups presented similar mean values at all tested periods. According to the results obtained, it could be concluded that, under the experimental conditions, ZOE cement was more effective in vitro against C. albicans than GIC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rhodococcus equi is a Gram-positive, facultative intracellular bacterium which infects macrophages and causes rhodococcal pneumonia and enteritis in foals. Recently, this agent has been recognized as an opportunistic pathogen for immunocompromised humans. Several murine experimental models have been used to study R. equi infection. High (H IV-A) and Low (L IV-A) antibody (Ab)-producers mice were obtained by bi-directional genetic selections for their ability to produce antibodies against sheep and human erythrocytes (Selection IV-A). These lines maintain their phenotypes of high and low responders also for other antigens than those of selection (multispeciflc effect). A higher macrophage activity in L IV-A mice has been described for several intracellular infectious agents, which could be responsible for their intense macrophage antigens (Ag)-handling and low Ab production. Due to these differences, L IV-A mice were found to exhibit a better performance to trigger an effective immune response towards intracellular pathogens. The objective of this work was to characterize the immune response of Selection IV-A against R. equi. H IV-A and L IV-A mice were infected with 2.0 × 10 6 CFU of ATCC 33701 +R. equi by intravenous route. With regards to bacterial clearance and survival assays, L IV-A mice were more resistant than H IV-A mice to virulent R. equi. L IV-A mice presented a higher hydrogen peroxide (H 2O 2) and nitric oxide (NO) endogenous production by splenic macrophages than H IV-A mice. L IV-A expressed the most intense cellular response, available by the Delayed-Type Hypersensitivity (DTH) reaction, which activated macrophages and produced more H 2O 2 and NO. The three times higher specific antibodies titres in H IV-A indicated that Selection IV-A maintained the multispecific effect and the polygenic control of humoral and cellular responses also to R. equi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microbial contamination of an enclosed area may come from outside or be generated within the area itself. In the study described here, bioaerosol levels in hospital air were quantified and related to those found in the air outside, taking into account some of the environmental variables that affect air quality, such as the number of occupants of a room and the type of ventilation. Airborne bacteria were collected for five minute by blowing air at 500 L min -1 in high speed jets on to the surface on plates culture in a single-stage bioaerosol impactor. The mean viable count of bacteria in the air outside in the hospital, São Paulo State, was 77 ± 4 CFU m -3, while in the air inside the hospital it was 302 ± 260 CFU m-3. The operating theatre was the only space sampled with a controlled environment and, after orthopedic surgery, it had the highest bioaerosol count recorded (867 ± 482 CFU m-3). In the enclosed environments, nine bacterial species were identified. Despite the difficulty in establishing precise numbers of bacteria in the bioaerosols in hospital environments, the values obtained demonstrate a need to instigate suitable programs to keep the microbial density low in these environments, and eliminate microorganisms presenting a significant risk to their occupants. It is also recommended that such programs include the monitoring of hospital air, with the aim of defining standards for acceptable numbers of bacteria in the bioaerosol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the effectiveness of microwave irradiation on the disinfection of simulated complete dentures. Materials and Methods: Eighty dentures were fabricated in a standardized procedure and subjected to ethylene oxide sterilization. The dentures were individually inoculated (10 7 cfu/mL) with tryptic soy broth (TSB) media containing one of the tested microorganisms (Candida albicans, Streptoccus aureus, Bacillus subtilis, and Pseudomonas aeruginosa). After 48 hours of incubation at 37°C, 40 dentures were individually immersed in 200 mL of water and submitted to microwave irradiation at 650 W for 6 minutes. Forty nonirradiated dentures were used as positive controls. Replicate aliquots (25 μL) of suspensions were plated at dilutions of 10 -3 to 10 -6 on plates of selective media appropriate for each organism. All plates were incubated at 37°C for 48 hours. TSB beakers with the microwaved dentures were incubated at 37°C for 7 more days. After incubation, the number of colony-forming units was counted and the data were statistically analyzed by Kruskal-Wallis test (α = .05). Results: No evidence of growth was observed at 48 hours for S aureus, B subtilis, and C albicans. Dentures contaminated with P aeruginosa showed small growth on 2 plates. After 7 days incubation at 37°C, no growth was visible in the TSB beakers of S aureus and C albicans. Turbidity was observed in 3 broth beakers, 2 from P aeruginosa and 1 from B subtilis. Conclusion: Microwave irradiation for 6 minutes at 650 W produced sterilization of complete dentures contaminated with S aureus and C albicans and disinfection of those contaminated with P aeruginosa and B subtilis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The efficacy of BCG vaccine (attenuated Mycobacterium bovis) against pulmonary tuberculosis varies enormously among different populations. The prevailing hypothesis attributes this variation to interactions between the vaccine and mycobacteria common in the environment. Studies have revealed that most protective antigens expressed by the antituberculous vaccine are conserved in M. avium, supporting the hypothesis that exposure to environmental mycobacteria generates a cross-reactive immune response that interferes with BCG efficacy. In this study we investigated the effect of a prior exposure to heat-killed M. avium on the immune response and the protective efficacy induced by a genetic vaccine pVAXhsp65 (hsp65 gene from M. leprae inserted in pVAX vector) against experimental tuberculosis. To evaluate the effect on the immune response, female BALB/c mice were initially injected with distinct doses (0.08×106, 4×106, and 200×10 6) of heat-killed M. avium by subcutaneous route. Three weeks later, the animals were immunized with 3 doses of DNAhsp65 by intramuscular route (100μg/15 days apart). Control groups received only M. avium, vaccine (pVAXhsp65), vector (pVAX) or saline solution. Cytokine production and antibody levels were determined by ELISA. To evaluate the effect on the protective efficacy, animals were initially sensitized with 200×106 heat-killed CFU of M. avium by subcutaneous route and then immunized with 3 doses of pVAXhsp65 (100μg/15 days apart) by intramuscular route. Control groups were injected with saline, pVAX (4 doses), pVAXhsp65 (4 doses), M. avium or M. avium plus pVAX (3 doses). Fifteen days after last DNA dose, the animals were infected with 1×104 viable CFU of H37Rv M. tuberculosis by intratracheal route. Thirty days after challenge, the animals were sacrificed and the bacterial burden was determined by counting the number of CFU in the lungs. Lung histological sections were also analyzed. Splenic cells from primed animals produced more IL-5 but less IFN-gamma than non-primed ones. Also, prior contact with M. avium determined higher production of IgG1 and IgG2a anti-hsp65 antibodies in comparison to control groups. However, this higher immune response did not decrease the bacterial burden in the lungs. In addition, prior sensitization with M. avium decreased the parenchyma preservation observed in the group immunized only with pVaxhsp65. These results indicate that environmental mycobacteria can interfere with immunity and protective efficacy induced by DNAhsp65.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the antimicrobial activity of different coffee solutions and their effects on the adherence of Streptococcus mutans to glass surface. Coffee solutions were prepared with three commercial products (Pilao, Mellita and Café do Ponto) by two different methods (simple and boiled) (n=15). A control group was also included in the study. For antimicrobial activity testing, tubes containing coffee solution and culture medium were inoculated with a suspension of S. mutans ATCC 35688 and incubated for 1 min 1h, 2h and 4h. Serial dilutions and plating on BHI agar were performed. S, mutans adherence to glass in presence of different coffee solutions was also tested. The number of adhered bacteria (CFU/mL) was determined by plating method. The results were statistically analyzed by ANOVA and Turkey's test. The tested coffee solutions did not reduce the number of colony forming units of S. mutans in relation to the control at all evaluation periods. All the solutions reduced significantly the adherence of S. mutans to the glass surface in relation to control. The tested coffee solutions did not present any antimicrobial effect on Streptococcus mutans, however, all the coffee solutions reduced significantly the adherence of S mutans to the glass surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water from dental equipment presents risks for surgeon-dentists as well as for patients because it might work as a means of dissemination/ transmission of microoganisms. The objective of this study was to verify the quality of the water used in dental equipment by means of microbiological analysis, accomplishing the count of Staphylococcus spp.There have been collected, 160 samples of water from reserviors, taps used for hand washing, air-water syringes, and high-speed handpieces, in 40 dental offices in the city of Barretos, São Paulo. The rules concerning bacteriotogicaI analysis in cfu/mL from Standard Methods for the Examination of Water and Wastewater have been followed. The analysis of the results has made it possible to verify that out of the total of samples, 28% did not meet the standards of potability established by the American Dental Association: Regarding the origin of analyzed S. aureus., the most contaminated sites were high-speed handpicces in private offices (761%) and in, ental care plan offices (71%), followed by air-water syringe in dental care plan offices (64%). For S. epidermitis samples, the most contaminated sites were high-speed handpieces in SUS (Brazilian Government Health System) dental offices (22%) and in dental care plan offices (14%) The most contaminated sites were dental offices that saw Patients under dental care plans, Concerning tested antibiotics, the ones that presented better results as to sensibility to strain S. epidermidis were vancomycin and ciprofloxacin (100%) and, as to sensibility to strain S. aureus, it was ciprofloxacin (97%).