409 resultados para Autogenous grinding


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the influence of different cross-head speeds on shear bond strength test on the dentin surface.Methods: One hundred and twenty extracted bovine incisors were embedded in polystyrene resin. The specimens were prepared by wet grinding with 320-, 400- and 600-grit Al2O3 paper exposing dentin. After the application of the adhesive system Single Bond (3M) to etched dentin, the composite resin Z-100 (3M) was applied and light cured. The specimens were randomly assigned to four groups (n = 30). The shear bond strength tests were performed with an EMIC DL 500 universal testing machine at four different cross-head speeds: 0.50 (A); 0.75 (B); 1.00 (C); and 5.00 mm/min (D).Results: the mean values of shear bond strength in MPa (SD) were: A, 11.78 (3.91); B, 11.82 (4.78); C, 16.32 (6.45); D, 15.46 (5.94). The data were analyzed with one-way ANOVA and Tukey's test (alpha = 0.05). The results indicated that A = B < C = D. The fracture pattern was evaluated by visual analysis in a stereomicroscope (25 x). The percentage of fractures that occurred at the adhesive interface were: A, 92.5%; B, 91.6%; C, 70.0%; D, 47.0%. The Student's t-test to percentages ( = 0.05) indicated that there were no significant differences among A, B and C; A and B differed from D, and there was no significant difference between C and D.Significance: Different cross-head speeds may influence the shear bond strength and the fracture pattern in dentin substrate. Shear bond strength using cross-head speeds of 0.50 and 0.75 mm/min should be preferred. (C) 2001 Academy of Dental Materials. published by Elsevier B.V. Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to establish equations to estimate the empty body chemical composition of Nellore steers using the following indirect techniques: 1) physical composition of the 9-10-11(th) rib cut;) physical composition of the 10(th) rib cut; and 3) chemical composition of the 10(th) rib cut. Thirty-one Nellore steers with weights ranging from 245 to 489 kg and ages from 20 to 29.7 months at slaughter were utilized. The empty body chemical composition was established through samples collected after grinding all animal tissues. The equations using the percentage of dissectable fat in the 9-10-11(th) rib cut shored a high precision for estimating the percentage of water (r(2) = 0.91; Syx = 1.168) and ether extract (r(2) = 0.94; Syx = 1.298) of the empty body; the same was observed when the percentage of dissectable fat in the 10(th) rib cut was used (r(2) = 0.82 and 0.85; Syx = 1.658 and 1.942, respectively, for water and ether extract). The equations using the percentage of ether extract in the 10(th) rib cut showed a high precision for estimating the percentage of water (r(2) = 0.89; Syx = 1.311) and the ether extract (r(2) = 0.89; Syx = 1.730) of the empty body, but there was no advantage over the physical composition of the 9-10-11(th) and 10(th) rib cut. Multiple regressions using carcass weight and the percentage of bones and kilograms of lean, fat, and bones dissectable in the 10(th) rib cut improved the coefficients of determination for water and ether extract to 0.87 and 0.91. The equations to estimate the percentages of protein and ach showed a low precision, indicating that those techniques are not recommended to estimate these components in the empty body of Nellore steers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Evaluation of the prevalence and characteristics of tinnitus in a Brazilian series of sleep bruxism patients. In this descriptive study, 100 patients (80 women and 20 men) were selected through the self-report of grinding teeth during sleep, confirmed by room mate or family member. They were evaluated according to a systematized approach: a questionnaire for orofacial pain and the Portuguese version of the Research Diagnostic Criteria for Temporomandibular Disorders. The patients were divided into two groups: group A, 54 patients with complaint of tinnitus and group B, 46 patients without tinnitus complaint. The mean age was 37.85 (13-66 years) and 34.02 years (20-59 years), respectively, for groups A and B (P = 0.1164). There was statistically significant difference between the two groups, with higher prevalence for the group A, in relation to: presence of chronic facial pain (P = 0.0007); number of areas painful to palpation in the masticatory and cervical muscles (P = 0.0032); myofascial pain in the masticatory muscles (P = 0.0003); absence of teeth without prosthetic replacement (P = 0.0145) and indices of depression (P = 0.0234). Structural alterations of the TMJ, like disc displacement and vertical dimension loss did not differ for the two groups. Tinnitus frequency was higher in patients with sleep bruxism and chronic facial pain. Myofascial pain, number of areas painful to palpation in the masticatory and cervical muscles, higher levels of depression and tooth absence without prosthetic replacement were more frequent in the group with tinnitus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes an analytical procedure for vanadium determination in human hair slurries by electrothermal AAS using longitudinal heating (LHGA) and transversal heating (THGA) graphite furnace atomizers. The samples were powdered using cryogenic grinding and the hair slurries containing 0.2% (m/v) were prepared in three different media for determination of vanadium: 0.14 mol L-1 HNO3, 0.1% (v/v) Triton X-100 and 0.1% (v/v) water soluble tertiary amines (CFA-C, pH 8). The limits of detection (LOD), limits of quantification (LOQ), and characteristic masses obtained were 0.28, 0.95 mu g L-1 and 35 pg (LHGA) and 0.34, 1.13 mu g L-1 and 78 pg (THGA), respectively. The accuracy of the analytical results obtained by the proposed procedure in both equipments was confirmed by a paired t-test at the 95% confidence level and compared with a conventional procedure based on acid digestion. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Grinding is a finishing process in machining operations, and the topology of the grinding tool is responsible for producing the desired result on the surface of the machined material The tool topology is modeled in the dressing process and precision is therefore extremely important This study presents a solution in the monitoring of the dressing process, using a digital signal processor (DSP) operating in real time to detect the optimal dressing moment To confirm the monitoring efficiency by DSP, the results were compared with those of a data acquisition system (DAQ) and offline processing The method employed here consisted of analyzing the acoustic emission and electrical power signal by applying the DPO and DPKS parameters The analysis of the results allowed us to conclude that the application of the DPO and DPKS parameters can be substituted by processing of the mean acoustic emission signal, thus reducing the computational effort

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The feasibility of Portland cement analysis by introduction of slurries in an inductively coupled plasma optical emission spectrometer (ICP-OES) with axial viewing has been evaluated. After a fast manual grinding of the cement samples, owing to the pulverized state of this material, 0.1% m/v slurries were prepared in 1% v/v HCl. The calibration was performed adopting two strategies: one based on slurries prepared from different masses (50, 75, 100 and 125 mg) of a Portland cement standard reference material (NIST SRM 1881), and the other one based on aqueous reference solutions. A complete analysis of cement for major (Al, Ca, Fe, Mg and Si), minor and trace elements (Mn, P, S, Sr and Ti) was accomplished. Both strategies led to accurate results for commercial Portland cement samples, except for Si and Ti. for which the calibration with aqueous reference solutions resulted in low values. Applying a paired t-test it was shown that most results were in agreement at a 95% confidence level with a conventional fusion decomposition procedure. The ICP-OES with axial viewing and end-on gas configuration for removal of the recombination plasma zone was effective for cement slurry analysis without any undesirable particle deposition in the pre-optics interface and without severe spectral interferences. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inferior Alveolar Nerve (IAN) transposition is an option for prosthetic rehabilitation in cases of moderate or even severe bone reabsorption for patients that do not tolerate removable dentures. The aim of the present report is to describe an inferior alveolar nerve transposition with involvement of the mental foramen for implant placement. The surgical procedure was performed under local anesthesia, by the inferior alveolar, lingual and buccal nerve blocking technique. Centripetal osteotomy was performed, and bone tissue was removed, leaving the nerve tissue free in the foramen area. After that, transsection of the incisor nerve was performed, and lateral osteotomy was started from the buccal direction, toward the trajectory of the IAN. The procedure was concluded, by making use of a delicate resin spatula to manipulate the vascular-nervous bundle. The drilling sequence for placing the dental implants was performed, and autogenous bone was harvested using a bone collector attached to the surgical suction appliance. After the implants were placed, the bone tissue previously collected during the osteotomies and drilling processes was placed in order to protect the IAN from contact with the implants. The surgical protocol for inferior alveolar nerve transposition, followed by implant placement presented excellent results, with complete recovery of the sensitivity, seven months after the surgical procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The family Meliaceae has been identified as one of the most promising for biological control, as most species have biologically active compounds. Among the species, the Neem (Azadirachta indica A. Juss) is that stands out most for its efficiency and low toxicity, and it is utilized to control insects, fungi and nematodes. The aim of this work was to verify the allelopathic potential of aqueous extract of fresh leaves of Neem on germination of lettuce, soybeans, maize, beans and Bidens pilosa, as a way to control this weed. The extract was obtained by grinding 200g/L of fresh leaves of the Neem (considered extract 100%) and diluting in distilled water at concentrations of 80, 60, 40, and 20%, and a control with only water. The seeds were kept in the germination chamber at a temperature of 25 degrees C, with photoperiod of 12 hours of light. The aqueous extract affected the germination percentage and average length root of lettuce, with values of 1% and 0.1, cm respectively. For the soybeans, the extract influenced negatively the average time of germination and average speed of germination. There was a drastic reduction of the average root length at higher concentration for soybean, corn and beans. For Bidens pilosa all the parameters analyzed were negatively affected, which means sensitivity to the extract. The bioassay performed in the laboratory showed that the aqueous extract of fresh leaves of Azadirachta indica has allelopathic effect on all species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work war to study the behavior of the plan tangential grinding process with conventional grinding wheels, under several machining conditions and a selected dressing condition. The analysis of the grinding performance was done regarding the cutting surface wear behavior of the grinding wheel for brittle and ductile steels workpieces. The grinding input parameters, which were, cutting speed, workpiece speed and cutting feed, were chosen based on the grinding machine characteristics. The results discussion emphasized the wear mechanism of the grinding wheel cutting surface and the cutting phenomenology of the grinding process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to evaluate the mechanism of stock removal and the ground surface quality of advanced ceramics grounded by a plane tangential grinding process with diamond grinding wheels. The analysis of the grinding performance was done regarding the cutting surface wear behavior of the grinding wheel for ceramic workpieces. The discussion about the results emphasized the wear mechanism of the grinding wheel cutting surface and the cutting phenomenology of the grinding process. The grounded surface was evaluated using Scanning Electron Microscopy (SEM). © 1999 Society of Automotive Engineers, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to evaluate the mechanism of stock removal and the ground surface quality of advanced ceramics machined by a surface grinding process using diamond grinding wheels. The analysis of the grinding performance was done regarding the cutting surface wear behavior of the grinding wheel for ceramic workpieces. The ground surface was evaluated using Scanning Electron Microscopy (SEM). As a result it can be said that the mechanism of material removal in the grinding of ceramic is largely one of brittle fracture. The increase of the hmax can reduce the tangential force required by the process. Although, it results in an increase in the surface damage, reducing the mechanical properties of the ground component.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Grinding is a precision machining process which is widely used in the manufacture of components requiring fine tolerances and smooth surfaces. There are several imput parameters (cutting conditions, cutting fluid and grinding wheel type used, dressing conditions etc.) which can affect the process variables (tangential and normal cutting forces, roughness, grinding temperatures, G ratio, etc.) leading to differences in the roughness, in the surface integrity and in the mechanical strength of the ground component. Consequently, the imput parameters must be controlled in order to insure the workpiece final quality. This paper presents a comparative evaluation of the performance of two types of grinding wheels [a conventional (Al2O3) and a superabrasive (CBN)] when grinding a VC131 steel, by the analysis of specific process variables when varying the cutting conditions. Highest values of G ratio and lowest workpiece roughness was observed when using CBN grinding wheels. This confirms the global trend of replacement of alumina grinding wheels by CBN, when grinding DTG (difficult to grind) materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the behavior of the steel surface grinding process with conventional grinding wheels was studied for various grinding conditions and a fixed dressing condition. The input parameters (wheel speed, workpiece speed, depth of cut), that set up the grinding conditions were determined as a function of the characteristics of the grinding machine. A test bench was established where the grinding power was measured in real time as a function of the volume of material removed. The results showed that in the grinding of fragile steels with a soft wheel and medium grit size, the average power of the cut shows a tendency to increase and become stabilized. The surface roughness of the piece decreased in all the tests and was proportional to the increase in the number of active grits. In tests on the grinding of ductile steels with a soft wheel and fine grit size, the wheel became dull until the moment that the abrasive grits were released from the cut surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The neutral hydrolysis reaction of post-consumer poly(ethylene terephthalate) in solid state was studied through the reaction of the polymer with water at the molar ratio 1:91 with autogenous pressure. Two sizes of post-consumer PET flakes and temperatures of 135 °C, 170°C and 205°C with pressures of 4.0 atm, 7.5 atm and 13.5 atm, respectively, were considered. With reaction time equal to 6h, the method reached 99% depolymerization at 205°C, 8.2% at 170 °C and 1.7% at 135°C. The reaction extension was measured by separating the terephthalic acid formed in the process and calculating by gravimetry how much material could still be reacted. Through the viscosimetry of diluted, solutions and the counting of carboxylic end groups in the remaining material from the gravimetric assay, it was possible to suggest that the reaction occurs randomly and in the whole volume of the polymeric particle and not solely on the surface. The terephthalic acid obtained and then purified was characterized by elemental analysis, magnetic nuclear resonance, size and panicle size distribution and spectrophotometry in the visible spectrum, and it was similar to the petrochemical equivalent, with purity recorded in carbon base equal to 99.9%.