163 resultados para Android,Multihoming,LISP,LISPmob,Performance,Test,Development,Analysis


Relevância:

50.00% 50.00%

Publicador:

Resumo:

A simple, rapid, selective and specific high performance liquid chromatographic (HPLC) method for quantitative analysis of the triamcinolone in polylactide-co-glycolide acid (PLGA) microparticles was developed. The chromatographic parameters were reversed-phase C18 column, 250mm x 4.6mm, with particle size 5 μm. The column oven was thermostated at 35°C ± 2°C. The mobile phase was methanol/water 45:55 (v/v) and elution was isocratic at a flow-rate of 1 mL.mL-1. The determinations were performed using a UV-Vis detector at 239 nm. The injected sample volume was 10 μL. The standard curve was linear (r2 > 0.999) in the concentration range 100-2500 ng.mL-1. The method showed adequate precision, with a relative standard deviation (RSD) was smaller than 3%. The accuracy was analyzed by adding a standard drug and good recovery values were obtained for all drug concentrations used. The method showed specificity and selectivity with linearity in the working range and good precision and accuracy, making it very suitable for quantitation of triamcinolone in PLGA microparticles.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The α-SiAlON ceramic cutting tool insert is developed. Silicon nitride and additives powders are pressed and sintered in the form of cutting tool inserts at temperature of 1900 °C. The physics and mechanical properties of the inserts like green density, weight loss, relative density, hardness and fracture toughness are evaluated. Machining studies are conducted on grey cast iron workpiece to evaluate the performance of α-SiAlON ceramic cutting tool. In the paper the cutting tool used in higher speed showed an improvement in the tribological interaction between the cutting tools and the grey cast iron workpiece resulted in a significant reduction of flank wear and roughness, because of better accommodation and the presence of the graphite in gray cast iron. The above results are discussed in terms of their affect at machining parameters on gray cast iron.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This paper reveals new contributions to the analysis and development of mitigating harmonic distortion devices. Considering the variety of sequential distribution of harmonic current, in the use of passive filters, one can point out the electromagnetic blocking device, which have received particular attention due to its robustness and low cost of installation. In this context, aiming the evaluation of the reliability of the results obtained through mathematical modeling, experimental tests are carried out using a low-power prototype, highlighting particular aspects related to its function as a zero-sequence harmonic blocking. © 2011 IEEE.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this study, curved maxillary molar root canals were instrumented with RaCe rotary system to evaluate: 1. the occurrence of canal transportation using a radiographic platform; 2. the action of the instruments on the dentin walls, centering ability and canal enlargement by analysis of digital images; and the percentage of regular dentin surfaces and debris within the canal by histological analysis. Ten mesiobuccal roots of extracted human maxillary molars were embedded in acrylic resin and sectioned at the middle and apical thirds. Root canal shaping was performed using the RaCe rotary system at 250 rpm and 1 Ncm torque. Each instrument set was used five times according to a crowndown technique in the following sequence: 40/0.10, 35/0.08, 25/0.06, 25/0.04, 25/0.02 (working length - WL), 30/0.02 (WL) and 35/0.02 (WL). Each instrument was inserted until resistance was felt and then pulled back, followed by brushing movements towards all canal walls. Each specimen was assessed by three study methods: radiographic platform, digitized image assessment and histological analysis. The radiographic platform showed lack of apical transportation. No statistically significant difference (Wilcoxon test, p>0.05) was found between the middle and apical thirds regarding instrument action on dentin walls, centering ability, area of root canal enlargement, percentage of regular dentin surfaces and debris within the root canal. It may be concluded that RaCe system is a suitable method for the preparation of curved root canals, regarding the maintenance of root canal original path, action on dentin walls, canal enlargement and removal of debris from the root canal lumen.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Purpose. - The purposes of this study were: i) to compare the physiological responses measured during a specific table tennis incremental test with the physiological responses measured during cycling, arm cranking, and treadmill running tests; and ii) to verify the accuracy of table tennis performance prediction based on the physiological responses from these tests.Methods. - Eleven national level male table tennis players participated in the study and undertook incremental tests using ergometers. Table tennis performance was defined as the ranking obtained during a simulated tournament between the participants.Results. - In general, peak values for physiological variables (e.g., (V) over dotO(2PEAK) and [La]PEAK) were significantly lower (P < 0.05) in the specific test (e.g., (V) over dotO(2PEAK) = 39.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 6.4 +/- 0.5 mmol.L-1) than during cycling (e.g., (V) over dotO(2PEAK) = 41.3 +/- 1.4 ml.kg(-1) per minute and [La]PEAK = 10.2 +/- 0.7 mmol.L-1) or running (e.g., (V) over dotO(2PEAK) = 43.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 10.0 +/- 0.7 mmol.L-1), but higher than during arm cranking (e.g., (V) over dotO(2PEAK) = 26.6 +/- 1.6 ml.kg(-1) per minute and [La]PEAK = 8.9 +/- 0.6 mmol.L-1). At respiratory compensation point intensity (RCP), only the variables measured on arm cranking were lower (P < 0.05) than on the other ergometers. Stepwise multiple regression analysis showed significant correlation between table tennis performance and lactate concentration ([La]) and also rate of perceived effort (RPE) at RCP during cycling (r = 0.89; P < 0.05).Conclusion. - In conclusion, the significant differences obtained between the specific and laboratory ergometers demonstrate the need to use a specific test to measure physiological parameters in table tennis and the physiological parameters measured, independent of the ergometer used, are unable to predict table tennis performance. (C) 2013 Elsevier Masson SAS. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

There is much concern about the social and environmental impacts caused by the economic growth of nations. Thus, to evaluate the socio-economic performance of nations, economists have increasingly addressed matters related to social welfare and the environment. It is within the scope of this context that this work discusses the performance of countries in the BRICS group regarding sustainable development. The objective of this study regards evaluating the efficiency of these countries in transforming productive resources and technological innovation into sustainable development. The proposed objective was achieved by using econometric tools as well as the data envelopment analysis method to then create economic, environmental, and social efficiency rankings for the BRICS countries, which enabled to carry out comparative analyses on the sustainable development of those countries. The results of such assessments can be of interest for more specific scientific explorations.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The goal of this study is to present and test a conceptual framework that describes the technical aspects (TA), human/organizational aspects (HOA) of the adoption of green product development (GPD) practices and the effect of these practices on firms'environmental (EP), operational (OP) and market performance (MP). To this end, after reviewing the literature on these themes, a conceptual framework with 5 hypotheses is proposed. These hypotheses were tested on 62 Brazilian companies through structural equation modeling using SmartPLS 2.0M3. The main results of this study are as follows: (a) in general, the proposed framework obtained adequate goodness of fit statistics (GoF); (b) technological factors are shown to have an influence on the adoption of GPD practices, and those practices are related to company EP, OP and MP, thus confirming 4 hypotheses of the study; and (c) one of the study's hypotheses is not validated, indicating that the relationship of human/organizational aspects to GPD must be further analyzed. This work extends the literature because: (a) the conceptual framework tested in this study establishes several concepts that have been only partially tested in the previous literature; (b) this work presents evidence about Brazil, where the themes addressed herein have not been yet been thoroughly investigated; and (c) the non-validation of the hypothesis regarding the relationship between human/ organizational aspects with respect to the adoption of product-related environmental practices requires attention. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A stability-indication high performance liquid chromatographic method has been developed for the determination of norfloxacin in tablet dosage forms. Optimum separation was achieved in less than 7 minutes using Eclipse Plus Zorbax C18 Agilent, 150 mm×4.6 mm i.d., 5 μm particle size column. The analyte was resolved by using a mobile phase 5% acetic acid aqueous solution and methanol (80:20, v/v) at a flow rate 1.0 ml/min on an isocratic high performance liquid chromatographic system at a wavelength of 277 nm. Linearity, system suitability, precision, sensitivity, selectivity, specific, and robustness were established by International Conference Harmonization guidelines. For stress studies the drug was subjected to photolysis, oxidation, acid, alkaline and neutral conditions. The analytical conditions and the solvent developed provided good resolution within a short analysis time and economic advantages. The proposed method not required sophisticated and expensive instrumentation.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The purpose of this study is to develop and validate a dissolution test for fluconazole, an antifungal used for the treatment of superficial, cutaneous, and cutaneomucous infections caused by Candida species, in capsules dosage form. Techniques by HPLC and UV first derivative spectrophotometry (UV-FDS) were selected for quantitative evaluation. In the development of release profile, several conditions were evaluated. Dissolution test parameters were considered appropriate when a most discriminative release profile for fluconazole capsules was yielded. Dissolution test conditions for fluconazole capsules were 900 mL of HCl 0.1 M, 37 ± 0.5 °C using baskets with 50 rpm for 30 min of test. The developed HPLC and UV-FDS methods for the antifungal evaluation were selective and met requirements for an appropriate and validated method, according to ICH and USP requirements. Both methods can be useful in the registration process of new drugs or their renewal. For routine analysis application cost, simplicity, equipment, solvents, speed, and application to large or small workloads should be observed.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)