153 resultados para reproducibility of calculated surfaces


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To calculate the estimated and actual height and weight measures in cancer patients, evaluate the correlation and concordance of these measures and to identify the malnutrition patients. 62 cancer patients, treated at the Amaral Carvalho Hospital (Jaú- SP). For classifi cation of nutritional status, the Patient-Generated Subjective Global Assessment, the Body Mass Index and the relationship with usual weight were used. For the estimated weight was used the algorithm Chumlea et al.7 and estimated height, the equation proposed by Chumlea et al.8 and Kwok & Whitelaw24. The Pearson Correlation Coeffi cient and the Intraclass Correlation Coeffi cient was calculated and simple linear regression was conducted. To compare the malnutrition detected by different methods, the Cochran’s Q test were performed. There was a strong and signifi cant correlation between the estimated and actual weight (r=0,95; CI95%=0,92-0,97; p<0,001) and excellent concordance (ρ=0,95). For height measurements, a signifi cant correlation was observed between the actual and estimated measurement the method Chumlea et al.8 (r=0,78; CI95%=0,66-0,86; p<0,001) and Kwok & Whitelaw24 (r=0,85; CI95%: 0,75-0,90; p<0,001). Concordance was “Good” (ρ=0,72) and “Moderate” (ρ=0,67) between the actual height and estimated by Chumlea et al.8 and Kwok & Whitelaw,24 respectively. There was a strong correlation between the actual and estimated weight and height measures. The reproducibility of the equation proposed by Chumlea et al.8 to calculate height was better. The nutritional status, the patients classifi ed as malnutrition was greater when using the Patient-Generated Subjective Global Assessment and the relationship with usual weight.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO: O objetivo do estudo foi estimar a validade e confiabilidade da Escala de atitudes em relação à Estatística (EAE) quando aplicada a estudantes de Ciências Farmacêuticas. A amostra de 253 estudantes foi subdividida em duas partes. Sessenta por cento da amostra foi utilizada para explorar a estrutura fatorial e 40% para confirmá-la. Para verificar a reprodutibilidade da escala a mesma foi aplicada em duplicata a 40 estudantes. Aplicou-se o Teste de esfericidade de Bartlett e o índice Kaiser-Meyer-Olkin (KMO). A extração dos fatores foi realizada pela Análise de Componentes Principais. Realizou-se rotação ortogonal Varimax. Calculou-se o Coeficiente alfa de Cronbach (α) e o Coeficiente de Correlação Intraclasse (ρ). Realizou-se análise fatorial confirmatória. Elaborou-se um modelo hierárquico de segunda ordem (MHSO). O teste de esfericidade de Bartlett e o índice KMO foram excelentes (χ 2 =1835,815, p<0,001; KMO=0,935). Verificou-se dois fatores com valores próprios acima de 1 (λ=9,748; λ=2,086) explicando 59,2% da variância total. A questão 2 foi removida. Observou-se excelente consistência interna e reprodutibilidade. O modelo fatorial apresentou índices de qualidade de ajustamento bons (λ=0,59-0,86, χ 2 /gl=1,691, CFI=0,919, GFI=0,804, RMSEA=0,079). A validade discriminante dos fatores foi adequada. A EAE apresentou estrutura bifatorial na amostra com níveis de validade e confiabilidade adequados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to investigate the reliability of visual and digital methods to assess marginal microleakage in vitro. Materials and Methods: Typical Class V preparations were made in bovine teeth and filled with composite resin. After dye penetration (0.5% basic fuchsin), teeth were sectioned and the 53 obtained fragments were assessed according to visual (stereomicroscope) and digital methods (Image Tool Software ® -ITS) (University of Texas Health Science Center-San Antonio Dental School, USA). Two calibrated examiners (A and B) evaluated dye penetration, by means of a stereomicroscope with ×20 magnification (scores), and by the ITS (millimeters). The intra- and inter-examiner agreement was estimated according to Kappa statistics (κ), and intraclass correlation coefficient (ρ). Results: In relation to the visual method, the intra-examiner agreement was almost perfect (κA = 0.87) and substantial (κB = 0.76), respectively to the examiner A and B. The inter-examiner agreement showed an almost perfect reliability (κ = 0.84). For the digital method, the intra-examiner agreement was almost perfect for both examiners and equal to ρ = 0.99, and so was the inter-examiner agreement value. Conclusion: Visual (stereomicroscope) and digital methods (ITS) showed high levels of intra- and inter-examiner reproducibility when marginal microleakage was assessed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The aim of this study was to compare pelvic floor muscle (PFM) strength using transvaginal digital palpation in healthy continent women in different age groups, and to compare the inter- and intra-rater reliability of examiners performing anterior and posterior vaginal assessments.Methods: We prospectively studied 150 healthy multiparous women. They were distributed into four different groups, according to age range: G1 (n = 37), 30-40 years-old; G2 (n = 39), 41-50 years-old; G3 (n = 39), 51-60 years-old; and G4 (n = 35), older than 60 years-old. PFM strength was evaluated using transvaginal digital palpation in the anterior and posterior areas, by 3 different examiners, and graded using a 5-point Amaro's scale.Results: There was no statistical difference among the different age ranges, for each grade of PFM strength. There was good intra-rater concordance between anterior and posterior PFM assessment, being 64.7%, 63.3%, and 66.7% for examiners A, B, and C, respectively. The intra-rater concordance level was good for each examiner. However, the inter-rater reliability for two examiners varied from moderate to good.Conclusions: Age has no effect on PFM strength profiles, in multiparous continent women. There is good concordance between anterior and posterior vaginal PFM strength assessments, but only moderate to good inter-rater reliability of the measurements between two examiners.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aims at identifying the influence of soil surface roughness from small to large aggregates (random roughness) on runoff and soil loss and to investigate the interaction with soil surface seal formation. Bulk samples of a silty clay loam soil were sieved to four aggregate-size classes of 3 to 12, 12 to 20, 20 to 45, 45 to 100 mm, and packed in soil trays set at a 5% slope. Rainfall simulations using an oscillating nozzle simulator were conducted for 90 min at an average rainfall intensity of 50.2 mm h(-1). Soil surface roughness was measured using an instantaneous profile laser scanner and surface sealing was studied by macroscopic analysis of epoxy impregnated soil samples. The rainfall simulations revealed longer times to initiate runoff with increasing soil surface roughness. For random roughness levels up to 6 mm, a decrease in final runoff rate with increasing roughness was observed. This can be attributed to a decreased breakdown of the larger roughness elements on rougher surfaces, thus keeping infiltration rate high. For a random roughness larger than 6 mm, a greater final runoff rate was observed. This was caused by the creation of a thick depositional seal in the concentrated flow areas, thus lowering the infiltration rates. Analysis of impregnated soil sample blocks confirmed the formation of a structural surface seal on smooth surfaces, whereas thick depositional seals were visible in the depressional areas of rougher surfaces. Therefore, from our observations it can be learned that soil surface roughness as formed by the presence of different aggregate sizes reduces runoff but that its effect diminishes due to aggregate breakdown and the formation of thick depositional seals in the case of rough soil surfaces. Sediment concentration increased with increasing soil surface roughness, due to runoff concentration in flow paths. Nevertheless, final soil loss rates were comparable for all soil roughness categories, indicating that random roughness is only important in influencing runoff rates and the time to initiate runoff, but not in influencing sediment export through soil loss rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurements on polymers (Teflon FEP and Mylar) have shown that the secondary electron emission from uncharged surfaces exceeds that from surfaces containing a positive surface charge. The reduced emission of charged surfaces is due to recombination between electrons undergoing emission and trapped holes within the charged layer. During the experiments the surface of the material was kept at a negative potential to assure that all secondary electrons reaching the surface from within the material are actually emitted. An analysis of the results yielded the maximum escape depth of the secondary electrons, and showed that the ratio of the maximum escape depth of the secondaries from Mylar to the maximum escape depth from Teflon is almost the same as the ratio of the corresponding second crossover energies of this polymers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Digital models are an alternative for carrying out analyses and devising treatment plans in orthodontics. The objective of this study was to evaluate the accuracy and the reproducibility of measurements of tooth sizes, interdental distances and analyses of occlusion using plaster models and their digital images. Thirty pairs of plaster models were chosen at random, and the digital images of each plaster model were obtained using a laser scanner (3Shape R-700, 3Shape A/S). With the plaster models, the measurements were taken using a caliper (Mitutoyo Digimatic(®), Mitutoyo (UK) Ltd) and the MicroScribe (MS) 3DX (Immersion, San Jose, Calif). For the digital images, the measurement tools used were those from the O3d software (Widialabs, Brazil). The data obtained were compared statistically using the Dahlberg formula, analysis of variance and the Tukey test (p < 0.05). The majority of the measurements, obtained using the caliper and O3d were identical, and both were significantly different from those obtained using the MS. Intra-examiner agreement was lowest when using the MS. The results demonstrated that the accuracy and reproducibility of the tooth measurements and analyses from the plaster models using the caliper and from the digital models using O3d software were identical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intra-abdominal adhesions constitute a significant clinical and surgical problem that can lead to complications such as pain and bowel occlusion or subocclusion. These adhesions are frustrating and potentially fatal, representing a major postoperative complication in abdominal surgery. It is estimated that 32% of horses undergoing laparotomy will present clinical symptoms due to adhesions, but the true prevalence is not known because a large proportion of animals with postoperative recurrent colics are medically treated or submitted to euthanasia without necropsy. Adhesions are highly cellular, vascularized, dynamic structures that are influenced by complex signaling mechanisms. Understanding their pathogenesis could assist in applying better therapeutic strategies and in developing more effective antiadhesion products. Currently, there are no definitive strategies that prevent adhesion formation, and it is difficult to interpret the results of existing studies due to nonstandardization of an induction model and evaluation of their severity. The best clinical results have been obtained from using minimally traumatic surgical techniques, anti-inflammatory agents, antimicrobials, anticoagulants, and mechanical separation of serosal surfaces by viscous intraperitoneal solutions or physical barriers. This paper aims to review adhesion formation pathogenesis, guide the understanding of major products and drugs used to inhibit adhesion formation, and address their effectiveness in the equine species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite its high incidence, patellofemoral pain etiology remains unclear. No prior study has compared surface electromyography frequency domain parameters and surface electromyography time domain variables, which have been used as a classic analysis of patellofemoral pain. Thirty one women with patellofemoral pain and twenty eight pain-free women were recruited. Each participant was asked to descend a seven step staircase and data from five successful trials were collected. During the task, the vastus medialis and vastus lateralis muscle activities were monitored by surface electromyography. The data were processed and analyzed in four variables of the frequency domain (median frequency, low, medium and high frequency bands) and three time domain variables (Automatic, Cross-correlation and Visual Onset between the vastus medialis and vastus lateralis muscles). Reliability, Receiver Operating Characteristic curves and regression models were performed. The medium frequency band was the most reliable variable and different between the groups for both muscles, also demonstrated the best values of sensitivity and sensibility, 72% and 69% for the vastus medialis and 68% and 62% for the vastus lateralis, respectively. The frequency variables predicted the pain of individuals with patellofemoral pain, 26% for the vastus medialis and 20% for the vastus lateralis, being better than the time variables, which achieved only 7%. The frequency domain parameters presented greater reliability, diagnostic accuracy and capacity to predict pain than the time domain variables during stair descent and might be a useful tool to diagnose individuals with patellofemoral pain.