180 resultados para heart left ventricle volume
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim this study was to evaluate systolic and diastolic function in volume overload induced myocardial hypertrophy in rats.Volume overload myocardial hypertrophy was induced in thirteen male Wistar rats by creating infrarenal arteriovenous fistula (AVF). The results were compared with a SHAM operated group (n = 11). Eight weeks after surgery, tail-cuff blood pressure was recorded, then rats were sacrificed for isolated heart studies using Langendorffs preparation.AVF rats presented increased left and right ventricular weights, compared to controls. The increased normalized ventricular volume (V0/LVW, 0.141 +/- 0.035 mL/g vs. 0.267 +/- 0.071 mL/g, P < 0.001) in the AVF group indicated chamber dilation. Myocardial hydroxyproline concentration remained unchanged. There was a significant decrease in +dP/dt (3318 +/- 352 mm Hg s(-1) vs. 2769 +/- 399 mm Hg s(-1); P=0,002), end-systolic pressure-volume relation (246 +/- 56 mm Hg mL(-1) vs. 114 +/- 63 mm Hg mL(-1);, P < 0,001), and -dP/dt (1746 +/- 240 min Hg s(-1) vs. 1361 +/- 217 mm Hg s(-1), P < 0.001) in the AVF group, which presented increased ventricular compliance (Delta V-25: SHAM=0.172 +/- 0.05 mL vs. AVF=0.321 +/- 0.072 mL, P < 0.001) with preserved myocardial passive stiffness (Strain(25): SHAM=13.5 +/- 3.0% vs. AVF=12.3 +/- 1.9%, P > 0.05).We conclude that volume-overload induced hypertrophy causes myocardial systolic and diastolic dysfunction with increased ventricular compliance. These haemodynamic features help to explain the long-term compensatory phase of chronic volume overload before transition to overt congestive heart failure. (c) 2006 European Society of Cardiology. Published by Elsevier B.V. All rights reserved.
Resumo:
The left ventricular mass (LVM) measurement is of major importance for renal patients, as ventricular hypertrophy is an important prognostic index. The echo-cardiogram of the ventricular mass is larger before than it is after hemodialysis, which can confuse data interpretation. The aim of this work is to study the influence of alterations in fluid volume on the variations in measurements of ventricular mass observed during the course of a hemodialysis. Sixteen patients with chronic renal insufficiency in hemodialysis were evaluated at the Dialysis Unit of the University Hospital-UNESP, Botucatu, São Paulo State. The left ventricular mass was calculated from echocardiograms taken before and after hemodialysis and simultaneous ultra-filtration (12 patients: UF GROUP) and before and after hemodialysis isovolemic phase with sequential ultra-filtration (10 patients: ISO GROUP). Six of these patients were submitted to measurements of left ventricular mass before and after hemodialysis in both isovolemic and simultaneous ultra-filtration procedures. In the UF group, there was significant reduction in the following parameters before and after dialysis: diastolic diameter from 54.0 +/- 6.0 mm to 45.6 +/- 7.6 mm; left ventricular mass from 342 +/- 114 g to 265 +/- 117 g; and its respective index (IMVE) from 214 +/- 68 g/m(2) to 168 +/- 71 g/m(2). The ISO group showed no statistically significant variation. The behavior of the variables of six patients submitted to both observations confirm these results. In conclusion, the variations in echocardiogram measurements of the left ventricular mass relating to hemodialysis appear to be induced by alterations of the volemic condition.
Resumo:
We report a case of a female patient that was referred to our service with progressive weakness and dyspnea. Three years ago, she had been submitted to hysterectomy and salpingo-oforectomy followed by adjuvant radiotherapy due to uterine cervix neuroendocrine tumor. Two-dimensional echocardiography showed a dense sessile mass in the right ventricle causing right and left ventricular filling restriction. Despite chemotherapy the patient died and necropsy confirmed metastases from neuroendocrine tumor to the right ventricle. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
The morphological characteristics of the ventricular myocardium and of coronary vascularization were studied in three freshwater teleost species, Piaractus mesopotamicus, Colossoma macropomum and Clarias gariepinus (African catfish), by correlating their ventricular shapes and swimming habits. In Piaractus mesopotamicus and Colossoma macropomum, species with highly active swimming habits, the cardiac ventricle showed a pyramidal shape and a richly vascularized myocardium consisting of an outer compact layer and inner spongy layer. In Clarias gariepinus, a less active species, we observed a saccular ventricle with a mixed myocardium and coronary arteries, in contrast to the ventricular structure of other species described in the literature.
Resumo:
The histological and ultrastructural characteristics of the heart ventricle in Clarias gariepinus (African catfish) has been studied by light microscopy and transmission electron microscopy. The ventricle of the heart has a saccular shape and the myocardial wall consists of an outer thin compact myocardium and an inner well-developed spongy myocardium. The myocardial layer has small myocytes, interstitial spaces and blood vessels. The myocytes are the major constituents of the ventricular wall. They are long cells, with large nuclei, and predominantly euchromatin. The sarcoplasmic reticulum of the ventricular myocytes consists of a network of tubules and subsarcolemmal cisternae oriented mainly along the longitudinal axis of the myofibrils. In contrast to the ventricular structure of other fish species described in the literature (Greer-Walker et al., 1985 Santer, 1985 Sanchez-Quintana et al., 1995, 1996), the African catfish, a freshwater sedentary fish recently introduced in neotropical climatic environments, showed a saccular ventricle that consisted of two muscle layers, a thin compact layer with large vessels and a developed spongy layer. The ultrastructure of the ventricular myocardium of C.gariepinus is similar to that of other teleosts, inclusive that of fish with other swimming habits.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Cardiovascular responses to central losartan (LOS), a non-peptide angiotensin II (ANG II) receptor antagonist, were investigated by comparing the effects of LOS injection into the 3rd and 4th cerebral ventricles (3rdV, 4thV) on mean arterial pressure (MAP) and heart rate (HR). Adult male Holtzman rats were used (N = 6 animals per group). Average basal MAP and HR were 114 +/- 3 mmHg and 343 +/- 9 bpm (N = 23), respectively. LOS (50, 100 or 200 nmol/2 mu l) injected into the 3rdV induced presser (peak of 25 +/- 3 mmHg) and tachycardic (peak of 60 +/- 25 bpm) responses. LOS injected into the 4thV had no effect on MAP, but it induced bradycardia (peak of -35 +/- 15 bpm). KCl (200 nmol/2 mu l) injected into the 3rdV or into the 4thV had no effect on either MAP or HR compared to 0.9% saline injection. The results indicate that LOS injected into the third ventricle acts on forebrain structures to induce its presser and tachycardic effects and that bradycardia, likely dependent on hindbrain structures, is obtained when LOS is injected into the fourth ventricle.
Resumo:
PURPOSE--To provide a critical analysis of the fluid filled manometric system and M-mode echocardiography and, by their association, to standardize the determination of left ventricular (LV) pressure-diameter and stress-diameter relationships in humans. MATERIAL AND METHODS--The pressure curve and the LV M-mode image was obtained in 24 patients with cardiopathy. The dynamic characteristics of the fluid-filled system have been studied to define the amplitude, the resonance and the time gap of the pressure curve register. The delay of the pressure curve recording was determined in all cases by comparing pressure curve and echocardiographic aortic valve registers. The values of pressure, diameter, posterior wall thickness and LV meridional stress was calculated at every 0.02s. RESULTS--Preliminary analyses of the fluid-filled manometric system indicated that this system has variable dynamic characteristics. The pressure-diameter and stress-diameter loops obtained were similar to those of the literature. The values of end-systolic stress, percentage of fractional shortening, ejection fraction and circumferential fiber shortening rate of patients with dilated cardiomyopathy (n = 5) were significantly reduced when compared to the values of patients without left ventricular overload (n = 8) and patients with ventricular volume overload. It has been verified, also, that the retard of the pressure curve record introduced by the fluid-filled manometric system does not modify the values of these variables. CONCLUSION--The LV pressure-diameter and stress-diameter relationships obtained by the association of echocardiography and LV manometry showed functional characteristics of the ventricle that could not appear by the use of the echocardiography or by the LV manometry themselves.
Resumo:
Cardiovascular responses to central losartan (LOS), a non-peptide angiotensin II (ANG II) receptor antagonist, were investigated by comparing the effects of LOS injection into the 3rd and 4th cerebral ventricles (3rdV, 4thV) on mean arterial pressure (MAP) and heart rate (HR). Adult male Holtzman rats were used (N=6 animals per group). Average basal MAP and HR were 114±3 mmHg and 343±9 bpm (N=23), respectively. LOS (50, 100 or 200 nmol/2 μl) injected into the 3rdV induced pressor (peak of 25±3 mmHg) and tachycardic (peak of 60±25 bpm) responses. LOS injected into the 4thV had no effect on MAP, but it induced bradycardia (peak of -35±15 bpm). KCl (200 nmol/2 μl) injected into the 3rdV or into the 4thV had no effect on either MAP or HR compared to 0.9% saline injection. The results indicate that LOS injected into the third ventricle acts on forebrain structures to induce its pressor and tachycardic effects and that bradycardia, likely dependent on hindbrain structures, is obtained when LOS is injected into the fourth ventricle.
Resumo:
Background: In a previous study utilizing the rat model, exposure to tobacco smoke for 5 weeks increased survival after AMI, despite similar age and infarct size between the smokers and nonsmokers, and absence of reperfusion. Objective: Thus, this study aimed to analyze the effects of exposure to tobacco smoke on intensity, distribution or phosphorylation of connexin 43 in the rat heart. Methods: Wistar rats weighing 100 g were randomly allocated into 2 groups: 1) Control (n = 25); 2) Exposed to tobacco smoke (ETS), n = 23. After 5 weeks, left ventricular morphometric analysis, immunohisthochemistry and western blotting for connexin 43 (Cx43) were performed. Results: Collagen volume fraction, cross-sectional areas, and ventricular weight were not statistically different between control and ETS. ETS showed lower stain intensity of Cx43 at intercalated disks (Control: 2.32 ± 0.19; ETS: 1.73 ± 0.18; p = 0.04). The distribution of CX43 at intercalated disks did not differ between the groups (Control: 3.73 ± 0.12; ETS: 3.20 ± 0.17; p = 0.18). ETS rats showed higher levels of dephosphorylated form of Cx43 (Control: 0.45 ± 0.11; ETS: 0.90 ± 0.11; p = 0.03). On the other hand, total Cx43 did not differ between control and ETS groups (Control: 0.75 ± 0.19; ETS: 0.93 ± 0.27; p = 0.58). Conclusion: Exposure to tobacco smoke resulted in cardiac gap junction remodeling, characterized by alterations in the quantity and phosphorylation of the Cx43, in rats hearts. This finding could explain the smoker's paradox observed in some studies.
Resumo:
The morphologically undivided ventricle of the heart in non-crocodilian reptiles permits the mixing of oxygen-rich blood returning from the lungs and oxygen-poor blood from the systemic circulation. A possible functional significance for this intra-cardiac shunt has been debated for almost a century. Unilateral left vagotomy rendered the single effective pulmonary artery of the South American rattlesnake, Crotalus durissus, unable to adjust the magnitude of blood flow to the lung. The higher constant perfusion of the lung circulation and the incapability of adjusting the right-left shunt in left-denervated snakes persisted over time, providing a unique model for investigation of the long-term consequences of cardiac shunting in a squamate. Oxygen uptake recorded at rest and during spontaneous and forced activity was not affected by removing control of the cardiac shunt. Furthermore, metabolic rate and energetic balance during the post-prandial metabolic increment, plus the food conversion efficiency and growth rate, were all similarly unaffected. These results show that control of cardiac shunting is not associated with a clear functional advantage in adjusting metabolic rate, effectiveness of digestion or growth rates. © 2013. Published by The Company of Biologists Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives To consensually validate the operational definitions of the nursing diagnoses activity intolerance, excessive fluid volume, and decreased cardiac output in patients with decompensated heart failure. Method Consensual validation was performed in two stages: analogy by similarity of defining characteristics, and development of operational definitions and validation with experts. Results A total of 38 defining characteristics were found. Operational definitions were developed and content-validated. One hundred percent of agreement was achieved among the seven experts after five rounds. Ascites was added in the nursing diagnosis excessive fluid volume. Conclusion The consensual validation improves interpretation of human response, grounding the selection of nursing interventions and contributing to improved nursing outcomes. Implications for Practice Support the assessment of patients with decompensated heart failure. Objetivos Realizar a validacAo consensual das definicoes operacionais dos diagnosticos de enfermagem Intolerancia a atividade, Volume de liquidos excessivo e Debito cardiaco diminuido em pacientes com insuficiencia cardiaca descompensada. Metodo ValidacAo consensual em duas etapas: Analogia de semelhanca das caracteristicas definidoras e desenvolvimento de definicoes operacionais e validacAo com expertst. Resultados Foram encontradas 38 caracteristicas definidoras para os diagnosticos de enfermagem. Suas definicoes operacionais foram desenvolvidas e seu conteudo validado. Os resultados mostram que houve 100% de concordancia entre os sete experts apos cinco rodada. As definicoes operacionais foram classificadas com base no nivel de concordanica. Ascite foi acrescentada ao diagnostico Volume de liquidos excessivo. ConclusAo A validacAo consensual melhora a interpretacAo das respostas humanas, embasando a selecAo de intervencoes de enfermagem e contribuindo para melhorar os resultados. Implicacoes Para A Pratica Apoio a avaliacAo dos pacientes com insuficiencia cardiaca descompensada.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)