262 resultados para electrical properties
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Low-density polyethylene (LDPE) was characterised for its dielectric and electrical properties before and after chemical treatment. A reduction in the permittivity and dielectric loss was observed in the polymer after treatment with hexane. The intensity in the Raman Spectrum in the disordered longitudinal acoustic mode region (DLAM) also was reduced due to a hexane treatment. Using thermally stimulated discharge current (TSDC) and laser-intensity-modulated method (LIMM) techniques it was observed that charge injection can be enhanced in the polymer matrix in the empty sites, created by the removal of the low molecular weight impurities with chemical treatment. (C) 2002 Kluwer Academic Publishers.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Os sistemas de telecomunicações emitem radiofreqüência, uma radiação eletromagnética invisível. Telefones celulares transmitem microondas (450900 MHz no sistema analógico e 1,82,2 GHz no sistema digital), muito próximo à orelha do usuário. Esta energia é absorvida pela pele, orelha interna, nervo vestibulococlear e superfície do lobo temporal. OBJETIVO: Revisar a literatura sobre influência dos telefones celulares na audição e equilíbrio. FORMA DE ESTUDO: Revisão sistemática. METODOLOGIA: Foram pesquisados artigos nas bases Lilacs e Medline sobre a influência dos telefones celulares nos sistemas auditivo e vestibular, publicados de 2000 a 2005, e também materiais veiculados na Internet. RESULTADOS: Os estudos sobre radiação do telefone celular e risco de neurinoma do acústico apresentam resultados contraditórios. Alguns autores não encontram maior probabilidade de aparecimento do tumor nos usuários de celulares, enquanto outros relatam que a utilização de telefones analógicos por 10 anos ou mais aumenta o risco para o tumor. A exposição aguda às microondas emitidas pelo celular não influencia a atividade das células ciliadas externas da cóclea, in vivo e in vitro, a condução elétrica no nervo coclear, nem a fisiologia do sistema vestibular em humanos. As próteses auditivas analógicas são mais suscetíveis à interferência eletromagnética dos telefones celulares digitais. CONCLUSÃO: Não há comprovação de lesão cocleovestibular pelos telefones celulares.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conjugated polymers have been subject of great interest in the recent literature from both fundamental point of view and applied science perspective. Among the several types of conjugated polymers used in recent investigations, polythiophene and its derivatives have attracted considerable attention over the past 20 years due to their high mobility and other remarkable solid-state properties. They have potential applications in many fields, such as microelectronic devices, catalysts, organic field-effect transistors, chemical sensors, and biosensors. They have been studied as gas and volatile organic compounds (VOCs) sensors using different principles or transduction techniques, such as optical absorption, conductivity, and capacitance measurements. In this work, we report on the fabrication of gas sensors based on a conducting polymer on an interdigitated gold electrode. We use as active layer of the sensor a polythiophene derivative: poly (3-hexylthiophene) (P3HT) and analyzed its conductivity as response for exposure to dynamic flow of saturated vapors of six VOCs [n-hexane, toluene, chloroform, dichloromethane, methanol, and tetrahydrofuran (THE)]. Different responses were obtained upon exposure to all VOCs, THF gave the higher response while methanol the lower response. The influence of moisture on the measurements was also evaluated. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
Resumo:
The properties of Langmuir and Langmuir-Blodgett (LB) films from a block copolymer with polyethylene oxide and phenylene-vinylene moieties are reported. The LB films were successfully transferred onto several types of substrates, with sufficient quality to allow for evaporation of a metallic electrode on top of the LB films to produce polymer light emitting diodes (PLEDs). The photoluminescence and electroluminescence spectra of the LB film and device were similar, featuring an emission at ca. 475 nm, from which we could infer that the emission mechanisms are essentially the same as in poly(p-phenylene) derivatives. Analogously to other PLEDs the current versus voltage characteristics of the LB-based device could be explained with the Arkhipov model according to which charge transport occurs among localized sites. The implications for nanotechnology of the level of control that may be achieved with LB devices will also be discussed.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Barium zirconium titanate (BZT) ceramics were prepared by mixed oxide method. X-ray diffraction showed the presence of a single phase while Raman scattering confirmed structural transitions as a function of different Zr/Ti ratio. The addition of Zr strongly influenced the crystal structure and electrical properties of the ceramics. A typical hysteresis loops were observed for all investigated compositions. BZT ceramics with 15 mol% Zr have shown a ferroelectric to paraelectric transition at around 77 degrees C. (C) 2007 Published by Elsevier B.V.
Resumo:
Thin films of lithium niobate were deposited on (100) silicon by the polymeric precursor method (Pechini method). Annealing in static air was performed at 500degreesC for 3 h. The films obtained were characterized by X-ray diffraction, scanning electron microscopy and transmission electron microscopy. Electrical characterization of the films pointed to ferroelectricity via hysteresis loop. The dielectric constant, dissipation factor and resistance were measured in the frequency region from 10 Hz to 10 MHz. At 1 MHz, the dielectric constant was 46 and the dissipation factor was 0.043. (C) 2002 Elsevier B.V. B.V. All rights reserved.