177 resultados para Water absorption


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cassava leaves can be considered an important nutritional source when compared to other commonly consumed vegetables leaves. Cassava leaves have high levels of protein, fiber and minerals, and arestill underexplored due to the lack of information regarding the use of them as afood product, as well as, their use as an industrial raw material. The consumption of cassava leaves in fresh form is impractical due to the presence of cyanide, thereby it is required a pretreatment to be performed to reduce this component. The objective of this study was to produce and characterize the four made with cassava leaves as its chemical composition, color, indices of absorption and water solubility, and pasting properties, aiming to provide information of interest for possible application as an ingredient in the food industry. Cassava leaf flour showed low moisture content (6.6 %)and significant amounts of fiber (30.68 %), protein (23.00 %), and total carbohydrate (22.27%). Drying and milling processes allowed to obtain a flour with a low content of total cyanide (0.3 mg 100g-1 ), and the presence of vitamin C (56.6 mg 100g-1 ) and β –carotene (38 mg 100g- 1 ). The color analysis of cassava leaf flour showed low lightness with, predominantly, green and yellow pigments. The cassava leaf flour presented good solubility (14.85 %) and water absorption (6.87 g gel. g-1 ). Pasting properties showed a low peak of viscosity and a higher final viscosity with a retrogradation tendency, indicating a low capacity of this flour to form gel. The flour of cassava leaves can be a good source of nutrition when used as a food ingredient in soups and pasta. However, it is not indicated to products that require high gel formation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Many efforts are currently oriented toward extracting more information from ocean color than the chlorophyll a concentration. Among biological parameters potentially accessible from space, estimates of phytoplankton cell size and light absorption by colored detrital matter (CDM) would lead to an indirect assessment of major components of the organic carbon pool in the ocean, which would benefit oceanic carbon budget models. We present here 2 procedures to retrieve simultaneously from ocean color measurements in a limited number of bands, magnitudes, and spectral shapes for both light absorption by CDM and phytoplankton, along with a size parameter for phytoplankton. The performance of the 2 procedures was evaluated using different data sets that correspond to increasing uncertainties: ( 1) measured absorption coefficients of phytoplankton, particulate detritus, and colored dissolved organic matter ( CDOM) and measured chlorophyll a concentrations and ( 2) SeaWiFS upwelling radiance measurements and chlorophyll a concentrations estimated from global algorithms. In situ data were acquired during 3 cruises, differing by their relative proportions in CDM and phytoplankton, over a continental shelf off Brazil. No local information was introduced in either procedure, to make them more generally applicable. Over the study area, the absorption coefficient of CDM at 443 nm was retrieved from SeaWiFS radiances with a relative root mean square error (RMSE) of 33%, and phytoplankton light absorption coefficients in SeaWiFS bands ( from 412 to 510 nm) were retrieved with RMSEs between 28% and 33%. These results are comparable to or better than those obtained by 3 published models. In addition, a size parameter of phytoplankton and the spectral slope of CDM absorption were retrieved with RMSEs of 17% and 22%, respectively. If these methods are applied at a regional scale, the performances could be substantially improved by locally tuning some empirical relationships.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mudas envasadas de Coleus blumei, com três meses de idade, foram submetidas a diferentes concentrações de cloreto de sódio (NaCl: 0,00; 0,25; 0,50 e 1,00%). Visando determinar a absorção osmótica, as mudas tiveram seus caules cortados a 10 cm acima do solo. Os caules remanescentes foram interligados a tubos de vidro por tubos flexíveis de borracha. Foram feitas leituras (cm) a cada 30 minutos dos níveis das colunas de água nos capilares, correspondentes às absorções osmóticas de água, sendo ao todo realizadas onze leituras. em outro momento, mudas de C. blumei, com a mesma idade das anteriores, receberam as mesmas concentrações de NaCl descritas anteriormente, e, ao ar livre, foram avaliadas em termos de transpiração e resistência estomática, usando-se para isto porômetro LI 1600. Usou-se delineamento em blocos casualizados, com cinco repetições, submetendo-se os dados à análise de variância e regressão polinomial. Verificou-se para todos os tratamentos aumento da absorção osmótica até três horas após a adição das soluções. A partir desse momento observou-se reversão da absorção osmótica proporcional ao aumento da concentração salina, sendo esse efeito mais pronunciado em 1,00 % de NaCl, o que reflete perdas crescentes de água pelas raízes. No controle a absorção osmótica apresentou comportamento crescente e linear com o passar do tempo. A transpiração foi proporcionalmente reduzida com o aumento da concentração salina.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Iridium-, Ru-, and W-coated platforms were prepared by thermal treatment of the transversely heated graphite atomizer and investigated for the simultaneous determination of As, Bi, Pb, Sb, and Se in tap water by electrothermal atomic absorption spectrometry. The maximum pyrolysis temperature for As and Bi increased in a modifier sequence W < Ru < Ir. For Pb, Sb, and Se, this sequence was W < Ru, It. Calculated characteristic masses in the presence of It, Ru, and W were 35, 33, and 35 pg for As; 63, 51, and 52 pg for Bi; 50, 32, and 34 pg for Pb; 40, 35, and 31 pg for Sb; and 39, 39, and 93 pg for Se, respectively. Ruthenium was elected as the optimum modifier.Repeatability of the measurements was typically < 6%. Recoveries of As, Bi, Pb, Sb, and Se added to tap water samples varied from 79 to 109%. Accuracy was also checked by analysis of five certified reference materials (CRMs) from the National Institute of Standards and Technology (NIST1640 - Trace Elements in Natural Water; NIST 1643d Trace Elements in Water) and High Purity Standards (Trace Metals in Drinking Water Standards, lots #812708, #591107, and #710710). A paired t-test showed that the results for the CRMs were in agreement at the 95% confidence level with the certified values. The graphite tube lifetime was about 650 firings. multi-element determination is particularly challenging due to the necessity of carefully optimizing compromise conditions.Based on the considerations listed above, the aim of this paper was to evaluate the behavior of Ir, Ru, and W as permanent modifiers for the simultaneous determination of As, Bi, Pb, Sb, and Se. The performance of the proposed procedure was also verified after the ETAAS analysis of tap waters and reference materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fuel cell is an emerging cogeneration technology that has been applied successfully in Japan, the USA and some countries in the European Union. This system performs direct conversion of the chemical energy of the oxidation of hydrogen from fuel with atmospheric oxygen into direct current electricity and waste heat via an electrochemical process relying on the use of different electrolytes (phosphoric acid, molten carbonate and solid oxide, depending on operating temperature). This technology permits the recovery of waste heat, available from 200 degreesC up to 1000 degreesC depending on the electrolyte technology, which can be used in the production of steam, hot or cold water, or hot or cold air, depending on the associated recuperation equipment. In this paper, an energy, exergy and economic analysis of a fuel cell cogeneration system (FCCS) is presented. The FCCS is applied in a segment of the tertiary sector to show that it is a feasible alternative for rational decentralized energy production under Brazilian conditions. The technoeconomic analysis shows a global efficiency or fuel utilization efficiency of 86%. Analysis shows that the exergy losses in the fuel cell unit and the absorption refrigeration system are significant. Furthermore, the payback period estimated is about 3 and 5 years for investments in fuel cells of 1000 and 1500 US$/kW, respectively. (C) 2001 Elsevier B.V. Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper is proposed the use of biogas generated in the Wastewater Treatment Plant of a Dairy industry. The objective is to apply a thermoeconomic analysis to the supplementary cold water production of an absorption refrigeration system (NH3 + H2O) by the burning of such gas. The exergoeconomic analysis is carried out to allow a comparison between an absorption refrigeration system and of an equivalent compression refrigeration system that uses NH3 as work fluid. The proposed exergoeconomic model uses functional diagrams and allows one to obtain the exergetic incremental functions for each component individually and for the system as a whole. The model minimizes the exergetic manufacturing cost (EMC) which represents the cost of supplementary cold water production at 1degreesC (exergetic base) needed for this dairy's cold storage. As a conclusion, the absorption refrigeration system is better than compression refrigeration system, when the biogas cost is not considered. 2004 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bats tend to have less intestinal tissue than comparably sized nonflying mammals. The corresponding reduction in intestinal volume and hence mass of digesta carried is advantageous because the costs of flight increase with load carried and because take-off and maneuverability are diminished at heavier masses. Water soluble compounds, such as glucose and amino acids, are absorbed in the small intestine mainly via two pathways, the transporter-mediated transcellular and the passive, paracellular pathways. Using the microchiropteran bat Artibeus literatus (mean mass 80.6 +/- 3.7 g), we tested the predictions that absorption of water-soluble compounds that are not actively transported would be extensive as a compensatory mechanism for relatively less intestinal tissue, and would decline with increasing molecular mass in accord with sieve-like paracellular absorption. Using a standard pharmacokinetic technique, we fed, or injected intraperitonealy the metabolically inert carbohydrates L-rhamnose (molecular mass = 164 Da) and cellobiose (molecular mass = 342 Da) which are absorbed only by paracellular transport, and 3-O-methyl-D-glucose (3OMD-glucose) which is absorbed via both mediated (active) and paracellular transport. As predicted, the bioavailability of paracellular probes declined with increasing molecular mass (rhamnose, 90 +/- 11%; cellobiose, 10 +/- 3%, n = 8) and was significantly higher in bats than has been reported for laboratory rats and other mammals. In addition, absorption of 3OMD-glucose was high (96 +/- 11%). We estimated that the bats rely on passive, paracellular absorption for more than 70% of their total glucose absorption, much more than in non-flying mammals. Although possibly compensating for less intestinal tissue, a high intestinal permeability that permits passive absorption might be less selective than a carrier-mediated system for nutrient absorption and might permit toxins to be absorbed from plant and animal material in the intestinal lumen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The number of the cities with canalized water and sewage treatment stations has increased lately and consequently having in mind the great concern on environment preservation and the quality of the water used by society. However, these stations are nowadays causing another kind of problem: a huge quantity of sludge as residue. Due to the implication of the residue on the environment and, consequently, to human life quality, performing of an accurate investigation about the components of such sludge, as well as the thermal stability of this residue in the environment become necessary. This paper presents a study on sludge from water and sewage treatment station, as well as the thermal characterization of residue. Such study was performed through FTIR, atomic absorption, thermoanalytical (TG/DTG, DTA) techniques, that made it possible to observe that the main components of the sludge are clay, carbonates and organic substance, presenting a low rate of metals and a unique thermal behavior since the sludge from the treatment station has a higher thermal stability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)