147 resultados para Six Minute Walk Test
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was evaluate the effects of three anesthetic combinations, ketamine-midazolam, ketamine-xylazine and tiletamine-zolazepam, on IOP in rabbits. In a experimental, blind, randomized, crossover study, six rabbits were anesthetized with each of 3 treatments in random order. Groups KM (ketamine, 30 mg/kg + midazolam, 1 mg/kg); KX (ketamine, 30 mg/kg + xylazine, 3 mg/kg); and TZ (tiletamine + zolazepam, 20 mg/kg). The drugs were mixed in the same syringe injected intramuscularly (IM) into the quadriceps muscle. IOP was measured before drug administration (baseline) and at 5-minute intervals for 30 minutes. The data were analyzed by a 2-way repeated measures ANOVA followed by Bonferroni test. All groups had significant decreases in IOP compared to baseline (p < 0.001). There was no difference between groups at any of the time points assessed (p > 0.05). Administration of either ketamine-midazolam, ketamine-xylazine, or tiletamine-zolazepam similarly decrease IOP in rabbits within 30 minutes of injection.
Resumo:
The sagittal split ramus osteotomy (SSRO) is a surgical technique used widely to treat many congenital and acquired mandibular discrepancies. Stabilization of the osteotomy site and the potential for skeletal relapse after the procedure are still major problems. The aim of this study was to compare the mechanical stability of six methods of rigid fixation in SSRO using a biomechanical test model. Sixty polyurethane replicas of human hemimandibles were divided into six groups. In group I, the osteotomies were fixed with two four-hole titanium miniplates; in group II, with one four-hole miniplate; in group III, with one four-hole miniplate + a bicortical screw; in group IV, with a grid miniplate; in group V, with a four-hole locking miniplate; and in group VI, with a six-hole miniplate. A linear load in the premolar region was applied to the hemimandibles. The resistance forces (N) needed to displace the distal segment by 1, 3, and 5 mm were recorded and the data transmitted from the load cell to a computer. One-way analysis of variance with Tukey's post hoc test was performed to compare the means between groups. For the three displacement conditions, there was a strong tendency for the 2.0-mm plate + screw and the grid plate to have higher values.
Resumo:
The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Obesity is a risk factor in the development of several respiratory diseases. Lung volumes tend to be decreased, especially expiratory reserve volume, increasing expiratory flow limitation during tidal breathing. Barometric whole-body plethysmography is a non-invasive pulmonary function test that allows a dynamic study of breathing patterns. The objective of this study was to compare pulmonary function variables between obese and non-obese cats through the use of barometric whole-body plethysmography. Nine normal-weight and six obese cats were placed in the plethysmograph chamber, and different respiratory variables were measured. There was a significant decrease in tidal volume per kilogram (P=0.003), minute volume per kilogram (P=0.001) and peak inspiratory and expiratory flows per kilogram (P=0.001) in obese cats compared with non-obese cats. Obesity failed to demonstrate a significant increase in bronchoconstriction index variable enhanced pause (Penh), as previously reported in humans and dogs. The results show that feline obesity impairs pulmonary function in cats, although a significant increase in bronchoconstriction indexes was not observed. Non-invasive barometric whole-body plethysmography can help characterise mechanical dysfunction of the airways in obese cats.
Resumo:
Coordenação de Aperfeiçoamento do Pessoal de Nível Superior (CAPES)
Resumo:
Context: The possibility of bleaching vital teeth with peroxide-based products considerably revolutionized esthetic dentistry. Aim: The aim of this clinical study was to evaluate tooth color change and dental sensitivity after exposure to preloaded film containing a 10% hydrogen peroxide whitening system (Opalescence Trθswhite Supreme). Materials and Methods: A total of 13 volunteers, aged 18 to 25 years, participated in this study. The patients used the whitening system once a day for 60 minutes during the 8-day study. For maxillary incisors and canines, the color change was visually evaluated with the Vita color scale before, immediately, and six months after the treatment. Tooth sensitivity was evaluated during the daily gel applications. All whitening applications were done in office and under the supervision of a dental professional. Statistical Analysis Used: The results were analyzed using the Friedman Test (nonparametric repeated measures ANOVA) at a level of 5%, and Dunn's Multiple Comparison Test at the level of 5%. Results: It was verified that the original mean color values observed at the baseline analysis differed significantly from those observed immediately after bleaching, as well as from those seen in the analysis at six months ( P = 0.001). There was no significant difference between the mean color values observed in the immediate time and in the analysis at six months ( P = 0.474). No tooth sensitivity was observed in any patients. Conclusion: It was concluded that the bleaching technique using the 10% hydrogen peroxide system was effective in a short period of time without tooth sensitivity during applications.
Resumo:
This study examined the influence of different speed increments during treadmill exercise tests on peak treadmill speed (Vpeak) and its relationship with a 1-h treadmill running performance. 18 male recreational and amateur runners (10-km running pace: 10–15 km·h−1) performed, in an alternate order, 3 continuous incremental exercise tests with different speed increments (0.5, 1.0 and 2.0 km·h−1) on a motorized treadmill to determine Vpeak. Thereafter they undertook a 1-h time trial on a treadmill. Vpeak was determined as either (a) the highest speed that could be maintained for a complete minute (Vpeak-60 s), (b) the speed of the last complete stage (Vpeak-C), or (c) the speed of the last complete stage added to the product of the speed increment and the completed fraction of the incomplete stage (Vpeak-P). The Vpeak values were highly influenced by the different speed-incremented rates and the Vpeak-P determined during the protocol comprising speed increments of 1 km·h−1 presented the highest correlation with 1-h time trial performance (r=0.89). The results suggest that a protocol with speed increments comprising 1 km·h−1 and with a 3-min stage duration should be used as standard for the determination of Vpeak to assess aerobic fitness and predict endurance performance in recreational runners. Furthermore, the Vpeak-P should be used for the determination of Vpeak.
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV