216 resultados para Serials Solutions
Resumo:
Postanesthetic pain is a relatively common complication after local anesthesia. This complication may be caused by the anesthetic technique or by the anesthetic solution used. Tissue reactions induced by the anesthetic solutions may be one of the factors resulting in pain after anesthesia. The objective of this study was to comparatively analyze tissue reactions induced by different anesthetic solutions in the subcutaneous tissue of rats. The following solutions were utilized: 2% lidocaine without vasoconstrictor; a 0.5% bupivacaine solution with 1:200,000 adrenaline; a 4% articaine solution and 2% mepivacaine, both with 1:100,000 adrenaline; and a 0.9% sodium chloride solution as a control. Sterilized absorbent paper cones packed inside polyethylene tubes were soaked in the solutions and implanted in the subcutaneous region. The sacrifice periods were 1, 2, 5, and 10 days after surgery. The specimens were prepared and stained with hematoxylin and eosin for histological analysis. The results showed that there is a difference in tissue irritability produced by the local anesthetic solutions. The results also showed that there is no relation between the concentration of the drug and the inflammatory intensity, that the mepivacaine and articaine solutions promoted less inflammatory reaction than the bupivacaine, and that the lidocaine solution produced the least intense inflammation.
Resumo:
Barium titanates doped with Nb5+, and Y3+, were prepared. The starting powders were synthesized from citrate solutions by the Pechini process and partial Pechini process in two steps. Sintering was performed in the range from 1310° up to 1380°C for 2 hours in air atmosphere. The structural study concerning the incorporation of Nb and Y ions in the barium titanate crystal lattice was performed by XRD, XANES and EXAFS techniques. The dielectric properties were analyzed and the relationship between properties and structure of doped barium titanate was established.
Resumo:
This paper investigates corrosion behavior in graphite refractory hot metal impregnated with ZrO 2 and CeO 2 carrying solutions used in Blast Furnace hearth, consisting of 50% graphite and 50% anthracite. Corrosions tests were carried out by means of finger test method in an induction furnace, using bar-shaped 30×30×280 mm test specimens and hot metal from CSN#2 Blast Furnace runner. The temperature chosen for this test was 1520°C and sixty-minute isotherm. Upon test completion, test specimens were characterized by their dimensional variation, X-ray diffractometry and Scanning Electronic Microscopy (SEM).
Resumo:
Alkaline materials have shown incompatibility with methylene blue dye in leakage experiments. The goal of the present study was to analyze the effect of different dyes on the evaluation of the apical sealing ability of Mineral Trioxide Aggregate root-end fillings. Fifty-six extracted human canines were submitted to root canal instrumentation and obturation. After apical resection, retrograde cavities were prepared and teeth were randomly divided into four experimental (n = 13) and two control groups (n = 2). The following root-end filling materials were used: groups 1 and 2--Pro Root MTA (Dentsply), groups 3 and 4--zinc oxide-eugenol cement (ZOE). Teeth in groups 1 and 3 were immersed in 2% methylene blue solution, while teeth in groups 2 and 4 were immersed in 0.2% rhodamine B in a reduced pressure environment for 48 hours. Teeth were then longitudinally sectioned and leakage was evaluated. Results were submitted to statistical analysis (ANOVA and Tukey's test). Group 1 presented the least leakage (p < 0.05). It was concluded that the evaluation of the sealing ability of MTA is influenced by the dye used, since this material presented better sealing ability when evaluated with Methylene Blue, but was similar to ZOE when evaluated with rhodamine B.
Resumo:
The validation of a simple, sensitive and specific agar diffusion bioassay, applying cylinder-plate method, for the determination of the antibiotic azithromycin in ophthalmic solutions is described. Using a strain of Bacillus subtilis ATCC 9372 as the test organism, azithromycin at concentrations ranging from 50.0 to 200.0 μg·mL-1 could be measured in 1.666 7 mg·mL-1 ophthalmic solutions. A prospective validation of the method showed that the method was linear (r = 0.999 9) and precise (RSD = 0.70) and accurate (it measured the added quantities). The results obtained by bioassay method could be statistically calculated by linear parallel model and by means of regression analysis and verified using analysis of variance (ANOVA). We conclude that the microbiological assay is satisfactory for quantification of azithromycin in ophthalmic solutions.
Resumo:
Alpinia purpurata (Vieill) K. Schum, common name red ginger belongs to Zingiberaceae family, and is a perennial, with nice inflorescences composed of layers of bracts arranged in spirals. The utilization of keeping-quality solutions seeks to prolong vase-life and to maintain the quality of cut flowers. This research was performed to evaluate the effect of seven pulsing solutions (during 24 hours) on water relations, quality (turgor, browning and curvature) and the longevity of cut red ginger. The experiment followed complete randomized design, in factorial arrangement. The following treatments were studied: 1) distilled water (control), 2) sucrose 2% + 8-hidroxyquinoline citrate 200 ppm, 3) sucrose 2%, 4) sucrose 2% + citric acid, 5) benzyladenine 10 μM, 6) benzyladenine 10 μmol + sucrose 2%, 7) quaternary ammonia 0,5 mL/L. There was no significant (P>0.05) reduction of the relative water content (RWC) of the inflorescence bracts, among solutions, in the first period (7 days) and in the second period (14 days) and, between the two periods for all treatments. Significant differences among RWC of some treatments were recorded after 16 days of vase life. The utilization of benzyladenine, benzyladenine plus sucrose and sucrose plus citric acid, in the pulsing solution, allowed to keep the flowers quality for longer periods than the other treatments.
Resumo:
Purpose: To analyze, in vitro, the effects of acetylsalicylic acid (aspirin) and acetic acid solutions on VX2 carcinoma cells in suspension and to examine the correlation between these effects and neoplastic cell death. Methods: The VX2 tumor cells (107 cells/ml) were incubated in solutions containing differing concentrations (2.5% and 5%) of either acetylsalicylic acid or acetic acid, or in saline solution (controls). Every five minutes, cell viability was tested (using the trypan blue test) and analyzed under light microscopy. Results: Tumor cell viability (in %) decreased progressively and, by 30 minutes, neoplastic cell death had occurred in all solutions. Conclusion: Based on this experimental model and the methodology employed, we conclude that these solutions cause neoplastic cell death in vitro.
Resumo:
The aim of this study was to evaluate the antimicrobial effect of biomechanical preparation using different irrigating solutions. Seventy-eight root canals from premolars of four dogs were used. After experimental induction of periapical lesions, the root canals were prepared using the following solutions for irrigation: Group 1) 2.5% sodium hypochlorite (NaOCl); Group 2) 2% chlorhexidine (CHX); Group 3) saline solution and Group 4) control group with no biomechanical preparation. The microbiological evaluation of the root canals was performed by counting the colony forming units (CFUs) using different culture mediums. Two absorbent paper cones were used in each root canal in order to collect the microbiological samples before, and thirty days after the biomechanical preparation. The culture plates were incubated in aerobic, anaerobic and microaerophilic environment. Statistical evaluation was carried out using analysis of variance, Tukey and Student tests. The results demonstrated that there was reduction in the number of microorganisms in the NaOCl and CHX groups (p<0.05). There was greater effectiveness in the chlorhexidine group. The group that used saline solution and the control group presented an increased number of microorganisms. It can be concluded that the use of antimicrobial irrigating solutions during biomechanical preparation promotes the reduction of endodontic microbiota. However, a considerable number of microorganisms were still observed.
Antimicrobial activity of coffee-based solutions and their effects on Streptococcus mutans adherence
Resumo:
The aim of this study was to evaluate the antimicrobial activity of different coffee solutions and their effects on the adherence of Streptococcus mutans to glass surface. Coffee solutions were prepared with three commercial products (Pilao, Mellita and Café do Ponto) by two different methods (simple and boiled) (n=15). A control group was also included in the study. For antimicrobial activity testing, tubes containing coffee solution and culture medium were inoculated with a suspension of S. mutans ATCC 35688 and incubated for 1 min 1h, 2h and 4h. Serial dilutions and plating on BHI agar were performed. S, mutans adherence to glass in presence of different coffee solutions was also tested. The number of adhered bacteria (CFU/mL) was determined by plating method. The results were statistically analyzed by ANOVA and Turkey's test. The tested coffee solutions did not reduce the number of colony forming units of S. mutans in relation to the control at all evaluation periods. All the solutions reduced significantly the adherence of S. mutans to the glass surface in relation to control. The tested coffee solutions did not present any antimicrobial effect on Streptococcus mutans, however, all the coffee solutions reduced significantly the adherence of S mutans to the glass surface.
Resumo:
Purpose: To evaluate the influence of the brush type as a earner of priming adhesive solutions and the use of paper points as a remover of the excess of these solutions on the push-out bond strength of resin cement to bovine root dentin. The null hypotheses were that brush type and the use of paper points do not affect the bond strength. Materials and Methods: The canals of 80 single-root bovine roots (16 mm in length) were prepared at 12 mm using the preparation drill (FRC Postec Plus, Ivoclar). Half of each root was embedded in acrylic resin and the specimens were divided into 8 groups, considering the factors brush type (4 levels) and paper point (2 levels) (n = 10): Gr 1: small microbrush (Cavi-Tip, SDI); Gr 2: Microbrush (Dentsply); Gr 3: Endobrush (Bisco); Gr 4: conventional brush (Bisco); Gr 5: Cavi-Tip (SDI) + paper points; Gr 6: Microbrush (Dentsply) + paper points; Gr 7: Endobrush (Bisco) + paper points; Gr 8: conventional brush (Bisco) + paper points. The root dentin was treated with a multistep total-etch adhesive system (All Bond 2). The adhesive system was applied using each microbrush, with and without using paper points. One fiber post was molded with addition silicon and 80 posts were made of resin cement (Duolink), The resin posts were luted (Duolink resin cement), and the specimens were stored for 24 h in water at 37°C. Each specimen was cut into 4 disk-shaped samples (1.8 mm in thickness), which were submitted to the push-out test. Results: The brush type (p < 0.0001) (small microbrush > microbrush = endobrush = conventional brush) and the use of paper points (p = 0.0001) (with > without) influenced the bond strength significantly (two-way ANOVA). The null hypotheses were rejected. Conclusion: The smallest brush (Cavi-Tip) and the use of paper points significantly improved the resin bond to bovine root dentin.
Resumo:
Recent progress in the solution of Schwinger-Dyson equations (SDE), as well as lattice simulation of pure glue QCD, indicate that the gluon propagator and coupling constant are infrared (IR) finite. We discuss how this non-perturbative information can be introduced into the QCD perturbative expansion in a consistent scheme, showing some examples of tree level hadronic reactions that successfully fit the experimental data with the gluon propagator and coupling constant depending on a dynamically generated gluon mass. This infrared mass scale acts as a natural cutoff and eliminates some of the ad hoc parameters usually found in perturbative QCD calculations. The application of these IR finite Green's functions in the case of higher order terms of the perturbative expansion is commented. © Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence.
Leaching of Ni and Cu from mine wastes (tailings and slags) using acid solutions and A. ferrooxidans
Resumo:
The objective of this work is to evaluate the acidic and biological leaching of tailings containing Ni/Cu from a flotation and smelting plant. Acidithiobacillus ferrooxidans, strain LR, was used for bioleaching at pH 1.8 and chemical controls were run parallel to that. The acidic leaching was done within 48 hours at pH 0.5 and 1.0. In the slag inoculated flasks the redox potential was high (600 mV), thus indicating oxidative bacterial activity, however, the obtained results after 15 days showed only around 13% Ni and 8% Cu extractions, which were not different to those of the controls. For the flotation tailings bioleaching extractions were approximately 45% for Ni and 16% for Cu while differing figures were obtained for the chemical controls. These were 30% and 12% respectively. Here we could observe that the presence of bacterial activity led to a higher solubility of Ni. Acid leaching of slag showed higher nickel and copper extractions: 56% and 24% respectively at pH 0.5 and 21% and 11% at pH 1.0. However, the acid consumption was 320 and 150 Kg/ton of slag, respectively, both much higher than in bacterial assays. These results indicated that Ni and Cu solubilization from the slag is acid dependent no matter the redox potential or ferric iron concentration of the leaching solution. For flotation tailings, acid treatment showed extractions of 23% for Ni and 16% for copper at pH 0.5 and 22% and 28%, respectively at pH 1.0. The acid consumption was also higher: 220 and 120 Kg/ton, at pH 0.5 and 1.0, respectively. Based on own findings we could observe that acid leaching is found to be more effective for slag, though the acid consumption is much higher, while for the flotation tailings, bacterial leaching seems to be the best alternative. © (2009) Trans Tech Publications.
Resumo:
Rational solutions of the Painlevé IV equation are constructed in the setting of pseudo-differential Lax formalism describing AKNS hierarchy subject to the additional non-isospectral Virasoro symmetry constraint. Convenient Wronskian representations for rational solutions are obtained by successive actions of the Darboux-Bäcklund transformations. ©2010 American Institute of Physics.
Resumo:
This study evaluated the efficacy of 2 types of rotary instruments employed in association with sodium hypochlorite (NaOCl) or EDTA in removing calcium hydroxide (CH) residues from root canals dentin walls. Forty-two mandibular human incisors were instrumented with the ProTaper System up to F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA and filled with a CH intracanal dressing. After 7 days, the CH dressing was removed using 4 techniques: NiTi rotary instrument size 25, 0.06 taper (K3 Endo) and irrigation with 17% EDTA (Group 1), NiTi rotary F1 instrument (ProTaper) and irrigation with 17% EDTA (Group 2), NiTi rotary instrument size 25, 0.06 taper and irrigation with 2.5% NaOCl (Group 3) and NiTi rotary F1 instrument and irrigation with 2.5% NaOCl (Group 4). Two roots without intracanal dressing were used as negative controls. Teeth were evaluated by scanning electron microscopy, in the cervical and apical canal thirds. None of the techniques removed the CH dressing completely. In the apical and cervical thirds, F1 instrument was better than instrument size 25, 0.06 taper in removing CH residues (p<0.05), regardless of the final irrigating solution. No difference was found between the irrigating solutions in the groups of F1 instrument and of instrument size 25, 0.06 taper (p>0.05). The negative controls had no CH residues on the dentin walls. In conclusion, the ProTaper F1 instrument was better than K3 Endo instrument size 25, 0.06 taper in the removal of CH intracanal medication, regardless of irrigating solution used.
Resumo:
We present a nonperturbative quantization of the two-dimensional massless gauged Thirring model by using the path-integral approach. First, we will study the constraint structure of model via the Dirac's formalism and by using the Faddeev-Senjanovic method we calculate the vacuum-vacuum transition amplitude in a Rξ-gauge, then we compute the Green's functions in a nonperturbative framework. © 2010 American Institute of Physics.