377 resultados para Screw Extrusion


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the effects of operational conditions of the extrusion process (temperature, moisture and protein content) in production of cassava snacks added of casein, aiming to provide information to the cassava processing industry. The cassava flour and casein were characterized as their chemical components and color. The experimental design followed the central composite rotational design with three factors. The obtained products were characterized as for rate of expansion, specific volume, color and hardness. Data analyses showed that the lower moisture, protein and temperature conditions provided desired expanded products with light color attributes, high expansion and low hardness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sorubim lima is a migratory catfish that do not reproduce in lenthic environments such as those formed after construction of hydroelectric power plants. An alternative for conservation of the species in these environments is the stocking with fingerlings produced in captivity. The technique used to reproduce it in captivity was the induction by carp pituitary hormone, with dosage of 5 mg.kg(-1) for females (1 mg.kg(-1) in the first dose and 4 mg.kg(-1) in the second) and 3 mg.kg(-1) for males (1 mg.kg(-1) in the first dose and 2 mg.kg(-1) in the second), with an interval of 14 hours. The determination of extrusion moment of oocytes was made by monitoring the migration of nucleus from central to peripheral position. After UTA 264.5 (accumulated thermal units) the oocytes were obtained by compression of the ventral region of the female, and male were sacrificed for extraction of sperm. The eggs were kept in an incubator and the time of hatching of larvae was 370 UTA. The larvae were initially fed with plankton and showed no cannibalism. Moreover, they were not demanding about the food, accepting prepared rations after fifteenth day of life. The weight gain of larvae was very low even close to 20 mm in length (14 days), not exceeding 0.05 mg per day. After that both weight and length increased rapidly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The morphological aspects of the hypopharyngeal glands were analyzed in worker bees of Apis mellifera of 15 and 30 days of age. The individuals were kept in a room with controlled temperature at 32degreesC where they received water and either a protein or a high energy food. Nurse and foraging workers were used as a control for the experiment. The morphological results showed that the different diets modified the cell death characteristics and intensified its occurrence. Both diets caused precocious glandular degeneration. However, this anticipation of cell death was more pronounced in the glandular tissue of the workers who received the high energy diet when compared to the glands of the bees fed with the protein meal.The degenerative signs observed were an intense cytoplasmic vacuolization, with a loss of cytoplasm and of the cell boundaries, dilation or condensation of the cells and nuclei, and nuclear fragmentation. At the end of the degenerative process, we observed the extrusion of nuclei and, finally, the dissolution of the glands. The hypopharyngeal glands' remains were found in the haemolymph.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foi investigada a ocorrência e caracterizada ultra-estruturalmente a eliminação de material nuclear eletrondenso (nuage) para o citoplasma durante a ovogênese e durante os estágios iniciais da espermatogênese de Piaractus mesopotamicus, um peixe do Pantanal Matogrossense de ciclo reprodutivo sazonal. Constataram-se nas células germinativas femininas dois momentos de eliminação desse material, na ovogônia e no ovócito em fase perinucleolar. Nas células masculinas, material com morfologia e comportamento muito semelhante foi encontrado na espermatogônia. em todos os casos, o material associou-se a mitocôndrias. A possível função desse material foi discutida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gel to liquid crystalline phase transition of the double-chained cationic dioctadecyldimethylammonium chloride and bromide (DODAX, X = Cl- or Br-) in aqueous vesicle dispersions prepared by non-sonication, sonication and extrusion has been investigated using high-sensitivity differential scanning calorimetry (DSC). The transition temperature (T-m) is a function of the preparation method, amphiphile concentration, vesicle curvature and nature of the counterion. DSC thermograms for DODAB and DODAC non-sonicated vesicle dispersions exhibit a single endothermic peak at T-m roughly independent of concentration up to 10 mM. Extrusion broadens the transition peak and shifts T-m downwards. Sonication, however, broadens slightly the transition peak and tends to shift T-m upwards suggesting that extrusion and sonication form vesicles with different characteristics. DODAC always exhibits higher T-m than DODAB irrespective of the preparation method. T-m changes as follows: T-m (sonicated) greater than or equal to T-m (non-sonicated) > T-m (extruded). Hysteresis of about 7 degrees C was observed for DODAB vesicle dispersions. (C) 2000 Elsevier B.V. Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Combined dynamic and static light scattering (DLS, SLS) and cryogenic transmission electron microscopy (cryo-TEM) were used to investigate extruded cationic vesicles of dioctadecyldimethylammonium chloride and bromide (DODAX, X being Cl- or Br-). In salt-free dispersions the mean hydrodynamic diameter, D-h, and the weight average molecular weight, M-w, are larger for DODAB than for DODAC vesicles, and both D-h and M-w increase with the diameter (phi) of the extrusion filter. NaCl (NaBr) decreases (increases) the DODAB (DODAC) vesicle size, reflecting the general trend of DODAB to assemble as larger vesicles than DODAC. The polydispersity index is lower than 0.25, indicating the dispersions are rather polydisperse. Cryo-TEM micrographs show that the smaller vesicles are spherical while the larger ones are oblong or faceted, and the vesicle samples are fairly polydisperse in size and morphology. They also indicate that the vesicle size increases with phi and DODAB assembles as larger vesicles than DODAC. Lens-shaped vesicles were observed in the extruded preparations. Both light scattering and cryo-TEM indicate that the vesicle size is larger or smaller than phi when phi is smaller or larger than the optimal phi* approximate to 200 nm. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the current study is to evaluate fresh-frozen human bone allografts (FHBAs) used in vertical ridge augmentation clinically and by computed tomography, and to analyze the resulting bone formation and graft resorption. Sixteen FHBAs were grafted in the maxillae and mandibles of 9 patients. The FHBAs, which were provided by the Musculoskeletal Tissue Bank of Marilia Hospital (Unioss), were frozen at -80A degrees C. After 7 months, dental implants were placed and bone parameters were evaluated. Vertical bone formation was measured by computerized tomography before (T0) and at 7 months (T1) after the surgical procedure. Bone graft resorption was measured clinically from a landmark screw head using a periodontal probe. The results were analyzed by Student's t-test. Significant differences existed in the bone formation values at T0 and T1, with an average change of 4.03 +/- A 1.69 mm. Bone graft resorption values were 1.0 +/- A 0.82 mm (20%). Implants were placed with varying insertion torque values (35-45 Ncm), and achieved primary stability. This study demonstrates that FHBAs promote satisfactory vertical bone formation with a low resorption rates, good density, and primary implant stability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the possibility of obtaining guided bone regeneration using a poly-tetrafluoroethylene (PTFE) nonporous barrier for 2 endosseous implants, partially inserted in tibiae of rabbits.Materials and Methods: Histologic characteristics of the interface between titanium implants (one group with titanium plasma-coated implants and the other group with acid-treated surfaces) and of the regenerated bone were also studied. Twenty screw-vent implants were placed in tibiae of 5 male New Zealand rabbits, 2 at the right side and 2 at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. At the experimental group the implants were with a PTFE nonporous barrier, whereas no barriers were used in contralateral implants. Animals were sacrificed 3 months after surgery and biopsy specimens were evaluated histologically and histomorphometrically under light microscopy. Student's t test was used for statistical analysis.Results: The histologic measurements showed a mean gain in bone height of 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control group, for the titanium plasma-spray and acid-treated implant surfaces, respectively.Conclusion: The results of the investigation revealed that the placement of implants protruding 3 nun from crestal bone defects may result in vertical bone augmentation using a nonporous PTFE barrier. (Implant Dent 2009;18:182-191)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to observe the clinical outcome of bone spreading and standardized dilation of horizontally resorbed bone during immediate implant placement using a "screw-type" configuration of expansion and threadformers. Fifty-three patients were included in this study, and 41 edentulous areas in anterior and posterior maxillas were treated. Sixty-eight implants were placed using an insertion torque of at least 40 Ncm. Abutments were delivered 4 to 6 months after implant placement. The overall failure percentage was 4.41% (3 failures). A retrieved analysis of I implant removed at 3 years after placement demonstrated bone resorption down to the level of the third thread. The bone spreader technique is different from Summers' osteotome, both in clinical use and in armamentarium. The main advantage of the crest-expanding technique is that it is a less invasive procedure; the facial wall expands after the medullary bone is compressed against the cortical wall. Within the limits of this preliminary study, the cumulative survival rate for this method of implant placement is 95.58% at 3 years. This study confirms that a bone spreader used in the maxilla shows an unusually low failure rate after 3 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study investigated the effect of porcelain firing on the misfit of implant-supported frameworks and analyzed the influence of preheat treatment on the dimensional alterations.Materials and Methods: Four external-hex cylindrical implants were placed in polyurethane block. Ten frameworks of screw-retained implant-supported prostheses were cast in Pd-Ag using 2 procedures: (1) control group (CG, n = 5): cast in segments and laser welded; and test group (TG, n = 5): cast in segments, preheated, and laser welded. All samples were subjected to firing to simulate porcelain veneering firing. Strain gauges were bonded around the implants, and microstrain values (mu epsilon = 10(-6)epsilon) were recorded after welding (M1), oxidation cycle (M2), and glaze firing (M3). Data were statistically analyzed (2-way analysis of variance, Bonferroni, alpha = 0.05).Results: The microstrain value in the CG at M3 (475.2 mu epsilon) was significantly different from the values observed at M1 (355.6 mu epsilon) and M2 (413.9 mu epsilon). The values at M2 and M3 in the CG were not statistically different. Microstrain values recorded at different moments (M1: 361.6 mu epsilon/M2: 335.3 mu epsilon/M3: 307.2 mu epsilon) did not show significant difference.Conclusions: The framework misfit deteriorates during firing cycles of porcelain veneering. Metal distortion after porcelain veneering could be controlled by preheat treatment. (Implant Dent 2012;21:225-229)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi o de estimar o consumo total e o diário de matéria seca do pasto, de vacas mestiças Holandês - Zebu, em piquetes de capim-elefante (Pennisetum purpureum Schum.). Três grupos de 24 vacas foram usados em piquetes (4,5 vacas/ha), pastejados por três dias e submetidos a diferentes períodos de descanso durante dois anos. Os tratamentos consistiram de descansos de 30 dias sem concentrado e 30, 37,5 e 45 dias com a suplementação de 2 kg de concentrado (20,6% de proteína bruta). de julho a outubro, as vacas receberam, como suplementação, cana-de-açúcar mais 1% de uréia. O consumo total de matéria seca foi estimado a partir da digestibilidade in vitro da matéria seca da extrusa e da produção fecal obtida com óxido crômico. Independentemente do tratamento, o consumo total foi 2,7; 2,9 e 2.9±0,03%, e o consumo de matéria seca do pasto foi de 1,9; 2,1 e 2,1±0,03% do peso vivo (p<0,05), respectivamente, no primeiro, segundo e terceiro dia de ocupação do piquete. Somente no verão, o consumo do pasto foi semelhante nos três dias de pastejo. A mistura cana-de-açúcar e uréia substituiu o pasto, principalmente no primeiro dia de pastejo, ocasião em que o consumo do pasto era mais baixo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Estudar as alterações agudas da interface entre os parafusos e o tecido ósseo vertebral, considerando o diâmetro do orifício-piloto em relação ao diâmetro interno do parafuso. MÉTODOS: O estudo foi realizado em carneiros e a segunda vértebra cervical selecionada para o estudo. Foram utilizados parafusos corticais de 3,5mm de diâmetro externo (2,4mm de diâmetro interno) e 14mm de comprimento. Foram formados quatro grupos experimentais: 1) orifício-piloto de 2,0mm e colocação do parafuso de 3,5mm; 2) orifício-piloto de 2,5mm e colocação do parafuso de 2,5mm; 3) orifício-piloto de 2mm sem colocação do parafuso; e 4) orifício-piloto de 2,5mm sem colocação do parafuso. RESULTADOS: O grupo 1 (orifício-piloto menor do que o diâmetro interno do parafuso) apresentou maior densidade óssea no interior da rosca do implante e maior densidade óssea na área em espelho do que o grupo 2 (orifício-piloto maior que o diâmetro interno do parafuso). A superfície de contato entre o tecido ósseo e o implante foi maior no grupo 2 em relação ao grupo 1. A comparação da densidade óssea na área em espelho entre os grupos com e sem implante (1 e 3) e (2 e 4) mostrou que a densidade óssea era maior nos grupos com o implante. Não foi observada diferença estatística entre as comparações dos grupos experimentais. CONCLUSÃO: A utilização de orifício-piloto de menor diâmetro em relação ao diâmetro interno do parafuso apresentou tendência a provocar maior compactação do osso ao redor do implante.