149 resultados para RMS roughnesses


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Individuals with Parkinson's disease (PD) seem to present asymmetric postural control, and the commitment to postural control that is a big factor of falls in this population. However, the asymmetry in the postural control of fallers and non fallers with PD and neurologically healthy elderly is not too much studied. The objective of the study is to analyze the asymmetry in postural control in different static positions of elderly patients with PD and healthy elderly fallers and non fallers. The study included 70 older adults with PD and 70 neurologically healthy (CG). The groups were matched for age, gender, height, weight and cognitive condition. It was evaluated the clinical, cognitive status and incidence of falls among its participants through weekly prospective follow-up of 4 months. Then, for each group, CG and PD, it was selected 12 elderly fallers and 12 elderly non fallers to evaluate postural control. Participants were evaluated through two force platforms in conditions of bipedal support, unipedal and tandem position. It was realized 3 attempts of 30s for each condition. For unipedal and tandem condition it was made 3 attempts for each lower limb. The parameters of interest of the center of pressure (CoP), were analyzed for each condition and compared by MANOVAs with factor group, fall and asymmetry. Post hoc Tukey tests were used to determine the relationships between them. The results show that CG individuals showed greater velocity and CoP area in relation to PD. It was verified that at the control group that non fallers individuals (CGN) had more displacement and RMS in the average lateral direction in the dominant limb when compared to the less affected limb of non fallers with PD (PDN). Faller individuals in the control group (CGF) had larger area in the non dominant limb when compared to the most affected leg of fallers individuals with PD (PDF). Still, the PDF individuals had higher RMS in anteroposterior feeling....

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aimed to assess the bacteriological quality of water used in the irrigation of vegetable gardens in the municipalities of Araraquara, Boa Esperança do Sul and Ibitinga, São Paulo, Brazil. A total of 80 samples of water used in the irrigation of 40 vegetable gardens were analyzed, two samples coming from each vegetable garden. They were collected at the same site in different months, which resulted in two sample collection groups. The most probable number (MPN/100mL) of total coliforms, thermotolerant coliforms and enterococci was identifi ed by means of the multiple tube technique. The analysis of the fi rst group samples showed quantities of thermotolerant coliforms above the amount allowed by current law for irrigation water (CONAMA Resolution n. 357) in nine cases. The owners of those vegetable gardens were then instructed in water disinfection procedures. After the analysis of the second group samples, it was noticed that only one sample did not meet the quality standards, and it was collected at a site where no disinfection procedure had been carried out. According to the results, 77.5% of the vegetable gardens were using water whose samples meet the quality standards. After the owners were instructed with regard to disinfection procedures, that number changed to 97.5%, which confi rms the importance of controlling and supervising irrigation water quality

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Para a realização deste experimento, foram utilizados um rebolo de óxido de alumínio instalado em uma retificadora plana, um dispositivo em forma de balança juntamente com o sensor de deslocamento, um sistema de aquisição de sinais e um dressador de ponta única de diamante. O processamento digital dos dados foi obtido com o software Matlab. Nos ensaios, foram aplicados diferentes graus de recobrimento e profundidade de dressagem e comparada a agressividade obtida. A partir dos dados resultantes, os parâmetros RMS, DPO e DPKS mostraram-se bons indicadores para a operação. Também ficou comprovado que para recondicionar e definir novas características para o rebolo é necessária a remoção de 120 um. Do estudo do espectro do dinal de EA, notou-se que não há componentes hormônicas com frequência superior a 200 KHz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zinc oxide (ZnO) and aluminum-doped zinc oxide (ZnO:Al) thin films were deposited onto glass and silicon substrates by RF magnetron sputtering using a zinc-aluminum target. Both films were deposited at a growth rate of 12.5 nm/min to a thickness of around 750 nm. In the visible region, the films exhibit optical transmittances which are greater than 80%. The optical energy gap of ZnO films increased from 3.28 eV to 3.36 eV upon doping with Al. This increase is related to the increase in carrier density from 5.9 × 1018 cm−3 to 2.6 × 1019 cm−3 . The RMS surface roughness of ZnO films grown on glass increased from 14 to 28 nm even with only 0.9% at Al content. XRD analysis revealed that the ZnO films are polycrystalline with preferential growth parallel to the (002) plane, which corresponds to the wurtzite structure of ZnO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zinc oxide (ZnO) and aluminum-doped zinc oxide (ZnO:Al) thin films were deposited onto glass and silicon substrates by RF magnetron sputtering using a zinc-aluminum target. Both films were deposited at a growth rate of 12.5 nm/min to a thickness of around 750 nm. In the visible region, the films exhibit optical transmittances which are greater than 80%. The optical energy gap of ZnO films increased from 3.28 eV to 3.36 eV upon doping with Al. This increase is related to the increase in carrier density from 5.9 × 1018 cm-3 to 2.6 × 1019 cm-3. The RMS surface roughness of ZnO films grown on glass increased from 14 to 28 nm even with only 0.9% at Al content. XRD analysis revealed that the ZnO films are polycrystalline with preferential growth parallel to the (002) plane, which corresponds to the wurtzite structure of ZnO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Baseado em um controlador digital de sinais, o sistema de monitoramento e detecção da queima em tempo real proposto neste estudo realiza a aquisição das sinais RMS de emissão acústica e da potência ativa do motor de acionamento do rebolo. Essas ações são necessárias para realizar o cálculo de estatísticas que foram utilizadas em trabalhos científicos e mostraram-se eficientes na detecção da queima em processos de retiticação. Dessa forma, é possível atuar sobre a retificadora, interrompendo seu funcionamento ou realizando correções nas variáveis do processo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os dados para este estudo foram obtidos mediante a implantação de um sistema de monitoramento por emissão acústica em uma retificadora plana tangencil. A dressagem foi realizada em rebolos convencionais e os resultados foram analisados tomando por base a relação com o desgaste volumétrico sofrido pelo diamante do dressador. As análises foram realizadas nos diamantes naturais dos tipos Brasil Extra e Mato Grosso e no sintético do tipo CVD. Os dados da emissão acústica de cada dressador foram divididos em faixas de frequência para filtrar possíveis interferências. Utilizando a faixa mais apropriada, foi possível elaborar uma curva característica para cada dressador e relacionar o desgaste do diamante com o sinal RMS da emissão acústica na faixa de frequência analisada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: O presente estudo buscou um indicador de classificação de presença de dor lombar baseado no tempo de resistência isométrica e em variáveis eletromiográficas. Material e Métodos: Para tanto participaram do presente estudo 40 voluntários do gênero masculino, os quais foram divididos em dois grupos de 20 voluntários, a saber: grupo sem dor lombar e grupo com dor lombar. Para a captação dos sinais eletromiográficos foram utilizados eletrodos de superfície descartáveis passivos de contato bipolar de Ag/AgCl conectados a um pré-amplificador de ganho de 20 vezes. A distância intereletrodos foi fixa em 20mm. Os eletrodos foram dispostos bilateralmente sobre os músculos longuíssimo do tórax, iliocostal lombar e multífido lombar. Foi utilizado um módulo de aquisição de sinais biológicos de 8 canais no qual foram conectados os eletrodos. Para a aquisição dos sinais foi utilizado um software específico (Aqdados 7-Lynx®) com a freqüência de amostragem calibrada em 2000 Hz. Com os equipamentos preparados e os eletrodos conectados os voluntários realizaram o teste de Sorensen, o qual consiste em sustentar o peso do tronco, em posição horizontal, até a exaustão voluntária. Para a análise dos sinais eletromiográficos foram utilizadas rotinas específicas em ambiente MatLab (MathWorks®). Neste software foi obtida a atividade eletromiográfica dos músculos selecionados durante o teste de contração isométrica até a exaustão para a determinação dos valores de root means quare (RMS) em pacotes de 1s a cada 0.5s (overlap). De cada espectro foram determinados os valores de frequência mediana (FM) e frequência média (Fmed) do sinal. Com a RMS, FM e Fmed foram obtidos também os valores de Razão ML/LT, Razão ML/IL e Razão IL/LT para cada variável. Com isto, os valores de RMS, FM e Fmed, juntamente com os valores de Razão ML/LT, Razão ML/IL e Razão IL/LT de cada variável, foram associados com o tempo...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA