147 resultados para Perceived Intensity
Resumo:
We evaluated the effects of a low intensity aerobic exercise protocol on cardiac remodeling and myocardial function in diabetic rats. Wistar rats were assigned into four groups: sedentary control (C-Sed), exercised control (C-Ex), sedentary diabetes (DM-Sed), and exercised diabetes (DM-Ex). Diabetes was induced by intraperitoneal injection of streptozotocin. Rats exercised for 9 weeks in treadmill at 11 m/min, 18 min/day. Myocardial function was evaluated in left ventricular (LV) papillary muscles and oxidative stress in LV tissue. Statistical analysis was given by ANOVA or Kruskal-Wallis. Echocardiogram showed diabetic groups with higher LV diastolic diameter-to-body weight ratio and lower posterior wall shortening velocity than controls. Left atrium diameter was lower in DM-Ex than DM-Sed (C-Sed: 5.73 ± 0.49; C-Ex: 5.67 ± 0.53; DM-Sed: 6.41 ± 0.54; DM-Ex: 5.81 ± 0.50 mm; P < 0.05 DM-Sed vs C-Sed and DM-Ex). Papillary muscle function was depressed in DM-Sed compared to C-Sed. Exercise attenuated this change in DM-Ex. Lipid hydroperoxide concentration was higher in DM-Sed than C-Sed and DM-Ex. Catalase and superoxide dismutase activities were lower in diabetics than controls and higher in DM-Ex than DM-Sed. Glutathione peroxidase activity was lower in DM-Sed than C-Sed and DM-Ex. Conclusion. Low intensity exercise attenuates left atrium dilation and myocardial oxidative stress and dysfunction in type 1 diabetic rats.
Resumo:
The characterization of the hyperbolic power-time (P-tlim) relationship using a two-parameter model implies that exercise tolerance above the asymptote (Critical Power; CP), i.e. within the severe intensity domain, is determined by the curvature (W') of the relationship. The purposes of this study were (1) to test whether the amount of work above CP (W>CP) remains constant for varied work rate experiments of high volatility change and (2) to ascertain whether W' determines exercise tolerance within the severe intensity domain. Following estimation of CP (208 ± 19 W) and W' (21.4 ± 4.2 kJ), 14 male participants (age: 26 ± 3; peak [Formula: see text]: 3708 ± 389 ml.min-1) performed two experimental trials where the work rate was initially set to exhaust 70% of W' in 3 ('THREE') or 10 minutes ('TEN') before being subsequently dropped to CP plus 10 W. W>CP for TEN (104 ± 22% W') and W' were not significantly different (P>0.05) but lower than W>CP for THREE (119 ± 17% W', P<0.05). For both THREE (r = 0.71, P<0.01) and TEN (r = 0.64, P<0.01), a significant bivariate correlation was found between W' and tlim. W>CP and tlim can be greater than predicted by the P-tlim relationship when a decrement in the work rate of high-volatility is applied. Exercise tolerance can be enhanced through a change in work rate within the severe intensity domain. W>CP is not constant.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Resumo:
The aim of this study was to verify the use of exertion subjective perception to control warm-up intensity performed by continuous running in children. Twenty-one children (11,4 ± 0,8 years, 45 ± 9,8 kg e 153,6 ± 9,6 cm), performed warm-up by continuous running in randomic order in three conditions with diferent intensities using rate of perceived exertion (RPE). The intensities were chosen according to RPE Borg CR-10 and the arbitrary units used were three (B3), Five (B5) and nine (B9). The heart rate (HR) and mean velocity of the run (VEL) were evaluated to analyse the intensity of the three warm-up conditions. Statistical analysis was done by annova one-way followed by post-hoc tukey test, considering significant level of 5%. There were significant increase in HR (B3= 112 ± 10, B5 = 140 ± 18 e B9 = 176 ± 21 bpm) and VEL (B3 = 4,01 ± 0,5, B5 = 7,09 ± 1,22 e B9 = 10,97 ± 1,70 km/h) between B5 and B9 condition compared to B3. Moreover, in both parameters B9 presented significantly higher results compared to the condition B5. It´s possible to control warm-up intensity performed by continuous running in children using RPE Borg CR-10.
Resumo:
Essential arterial hypertension is the most common risk factor for cardiovascular morbidity and mortality. Regular exercise is a well-established intervention for the prevention and treatment of hypertension. Continuous moderate-intensity exercise training (CMT) that can be sustained for 30 min or more has been traditionally recommended for hypertension prevention and treatment. On the other hand, several studies have shown that high-intensity interval training (HIT), which consists of several bouts of high-intensity exercise (~85% to 95% of HRMAX and/or VO2MAX lasting 1 to 4 min interspersed with intervals of rest or active recovery, is superior to CMT for improving cardiorespiratory fitness, endothelial function and its markers, insulin sensitivity, markers of sympathetic activity and arterial stiffness in hypertensive and normotensive at high familial risk for hypertension subjects. This compelling evidence suggesting larger beneficial effects of HIT for several factors involved in the pathophysiology of hypertension raises the hypothesis that HIT may be more effective for preventing and controlling hypertension.
Resumo:
This study presents an analysis of the discomfort in the use of a cheese grater. Data was collected using a protocol of perceived discomfort and the results show that the subjects with no experience in cooking reported more experiences of discomfort and higher intensity than the subjects with experience in cooking.
Resumo:
Anaerobic efforts are commonly required through repeated sprint during efforts in many sports, making the anaerobic pathway a target of training. Nevertheless, to identify improvements on such energetic way it is necessary to assess anaerobic capacity or power, which is usually complex. For this purpose, authors have postulated the use of short running performances to anaerobic ability assessment. Thus, the aim of this study was to find a relationship between running performances on anaerobic power, anaerobic capacity or repeated sprint ability. Methods Thirteen military performed maximal running of 50 (P50), 100 (P100) and 300 (P300) m on track, beyond of running-based anaerobic sprint test (RAST; RSA and anaerobic power test), maximal anaerobic running test (MART; RSA and anaerobic capacity test) and the W′ from critical power model (anaerobic capacity test). Results By RAST variables, peak and average power (absolute and relative) and maximum velocity were significantly correlated with P50 (r = −0.68, p = 0.03 and −0.76, p = 0.01; −0.83, p < 0.01 and −0.83, p < 0.01; and −0.78, p < 0.01), respectively. The maximum intensity of MART was negatively and significantly correlated with P100 (r = −0.59) and W′ was not statistically correlated with any of the performances. Conclusion MART and W′ were not correlated with short running performances, having a weak performance predicting probably due to its longer duration in relation to assessed performances. Observing RAST outcomes, we postulated that such a protocol can be used during daily training as short running performance predictor.
Resumo:
Purpose The aim of the present study was to evaluate the effects of intensity and interval of recovery on performance in the bench press exercise, and the response of salivary lactate and alpha amylase levels. Methods Ten sportsman (aged 29 ± 4 years; body mass index 26 ± 2 kg/cm2 ) were divided in two groups: G70 (performing a bench press exercise at 70 % one repetition maximum—1RM), and G90 (performing a bench press exercise at 90 %—1RM). All groups were engaged in three intervals of recovery (30, 60 and 90 s). The maximum number of repetitions (MNR) and total weight lifted were computed, and saliva samples were collected 15 min before and after different intervals of recovery. For the comparison of the performance and biochemistry parameters, ANOVA tests for repeated measurements were conducted, with a significance level set at 5 %. Results In G70, the 30 s MNR was lower than the 60 and 90 s intervals of recovery (p\0.05) and the MNR with the 60 s interval of recovery was lower than the 90 s interval of recovery (p\0.041). Similarly, in G90 with the 30 s of interval of recovery, the sets were lower than observed with the 60 and 90 s (p\0.05), and MNR with the 60 s interval of recovery was lower than the 90 s interval of recovery (p\0.05). The salivary lactate showed an increase after exercise (p\0.05) when compared with the rest period for all groups, and no effects were observed for salivary alpha amylase. Conclusions Based on this result, the sets and reps can be modified to change the recovery time. This effect is very useful to improve the performance in relationship to different fitness levels.
Resumo:
Objective The present study aimed to examine the reproducibility of heart rate (HR) and rating of perceived exertion (RPE) values obtained during different incremental treadmill tests. Equipment and methods Twenty male, recreational, endurance-trained runners (10-km running pace: 10–15 km·h−1) performed, in a counterbalanced order, three continuous incremental exercise tests with different speed increments (0.5 km·h−1, 1 km·h−1 and 2 km·h−1). Thereafter, each participant performed the three tests again, maintaining the same order as before. The reproducibility of the HR and RPE values were analyzed for all protocols during submaximal intensities (8, 10, 12, and 14 km·h−1). In addition, it was examined the reproducibility of maximal HR (HRmax) and peak RPE (RPEpeak). Results The variability of both the HR and RPE values showed a tendency to decrease over the stages during the incremental test and was not or slightly influenced by the incremental test design. The HR at 14 km·h−1 and HRmax presented the highest reproducibility (CV < 2%). In contrast, the submaximal RPE values showed higher variability indices (i.e., CV > 5.0%). In conclusion, the HR values were highly reproducible during the stages of the incremental test, in contrast to the RPE values that presented limited reproducibility.