310 resultados para NaCl concentrations
Resumo:
Dynamic light scattering, surface tension, and clouding temperature have been monitored to elucidate the solution properties of mixed micelles formed between the anionic surfactant sodium dodecyl sulfate (SDS) and the nonionic surfactant pentaethylene glycol mono-n-dodecyl ether (C12E5) over a wide range of surfactant concentration and temperature. Addition of 0.1 M NaCl shifts the relaxational modes to higher frequency and lowers the clouding temperature (T-c) of the nonionic surfactant solution by about 1 degrees C compared to the salt-free system. T-c for the mixed surfactant solutions is higher than that of the binary C12E5 solutions and depends sensitively on the concentration of the two surfactants but increases only slightly when the total surfactant concentration is increased at a given molar C12E5/SDS concentration ratio. With C12E5/SDS = 5.7, for example, T-c is 46.0 and 47.5 degrees C, respectively, at 5 and 70 mM of C12E5 the mixed solutions are homogeneous and stable and contain nonspherical micelles, which are close to monodisperse over a range of surfactant concentrations and temperature. The mixed system has a lower Krafft point than binary SDS solutions and shows an approximately ideal behavior in contrast to the binary C12E5 solution. The hydrodynamic radius (RH) of the mixed micelle increases with temperature as do C12E5 micelles in the binary solutions and also with increasing C12E5/SDS ratio. At 25 degrees C, the critical micelle concentration of the mixed solution lies between those of the individual surfactants and decreases as the C12E5/SDS ratio is increased.
Resumo:
Purpose: To determine the influence of different dentin treatments on the microtensile bond strengths of adhesive resins to dentin. Methods: Fifteen human molars were ground to 600-grit to obtain flat root-dentin surfaces. Five different dentin treatments were evaluated: Group 1 - 10% phosphoric acid for 30 seconds; Group 2 - 37% phosphoric acid for 15 seconds; Group 3 - air-abrasion for 10 seconds followed by 10% phosphoric acid for 30 seconds; Group 4 - air-abasion for 10 seconds followed by 37% phosphoric acid for 15 seconds. The dental adhesive (OptiBond Solo Plus) was applied according to manufacturer's instructions and followed by composite (Z100) application to provide sufficient bulk for microtensile bond testing. All samples were placed in distilled water for 24 hours at 37degreesC, thermocycled for 500 cycles in distilled water at 10degreesC and 50degreesC, and serially sliced perpendicular to the adhesive surface and subjected to tensile forces (0.5 mm/minute). Additional samples were prepared for SEM to observe the adhesive interface. Results: Group 2 exhibited significantly (P< 0.05) lower bond strength values than all other treatments. The bond strengths of the different conditions were (in MPa): Group 1: 43.0 +/- 16.1; Group 2: 29.2 +/- 8.3; Group 3: 48.1 +/- 14.2; Group 4: 41.0 +/- 9.3. The dentin treated with phosphoric acid 37% for 15 seconds showed the lowest values of microtensile bond strength. The results obtained with Groups 1, 3 and 4 were statistically similar.
Resumo:
We present a recent development in holography with multimode, large free-spectral range (FSR) diode lasers in photorefractive sillenite crystals. A novel refractometry method based on this type of holographic recording in Bi12TiO20 (BTO) crystals is proposed. The holographic image of a prism-shaped transparent sample appears covered of interference fringes, and as the sample is properly translated, the fringes run along the holographic image. An expression providing the refractive index of the medium as a function of the sample displacement and the correspondent number of running fringes was derived. The refractive indexes of optical (BK7) glass, ethanol, hexan, cumene and aqueous solution of NaCl with different concentrations were measured in order to test the method. The obtained results are in good agreement with the ones reported in literature or measured by us using a commercial Abbe refractometre. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Objective-To evaluate the isoflurane-sparing effects of lidocaine and fentanyl administered by constant rate infusion (CRI) during surgery in dogs.Design-Randomized prospective study.Animals-24 female dogs undergoing unilateral mastectomy because of mammary neoplasia.Procedures-After premedication with acepromazine and morphine and anesthetic induction with ketamine and diazepam, anesthesia in dogs (n = 8/group) was maintained with isoflurane combined with either saline (0.9% NaCl) solution (control), liclocaine (1.5 mg/kg [0.68 mg/lb], IV bolus, followed by 250 mu g/kg/min [113 mu g/lb/min], CRI), or fentanyl (5 mu g/kg [2.27 mu g/lb], IV bolus, followed by 0.5 mu g/kg/min [0.23 mu g/lb/min], CRI). Positive-pressure ventilation was used to maintain eucapnia. An anesthetist unaware of treatment, endtidal isoflurane (ETiso) concentration, and vaporizer concentrations adjusted a nonprecision vaporizer to maintain surgical depth of anesthesia. Cardiopulmonary variables and ETiso values were monitored before and after beginning surgery.Results-Heart rate was lower in the fentanyl group. Mean arterial pressure did not differ among groups after surgery commenced. In the control group, mean +/- SD ETiso values ranged from 1.16 +/- 0.35% to 1.94 +/- 0.96%. Fentanyl significantly reduced isoflurane requirements during surgical stimulation by 54% to 66%, whereas the reduction in ETiso concentration (34% to 44%) observed in the lidocaine group was not significant.Conclusions and Clinical Relevance-Administration of fentanyl resulted in greater isoflurane sparing effect than did liclocaine. However, it appeared that the low heart rate induced by fentanyl may partially offset the improvement in mean arterial pressure that would be expected with reduced isoflurane requirements.
Resumo:
Background: Detection of systemic inflammation, which is important for proper diagnosis and prompt treatment, can be challenging.Hypothesis: Measurement of plasma iron concentration is a sensitive method for detecting systemic inflammation in horses compared with measurements of plasma Fibrinogen concentration, a traditional marker for inflammation in the horse.Animals: Ninety-seven horses hospitalized with diseases causing systemic inflammation, 22 horses with localized inflammation, and 12 clinically normal horses were included in this study.Methods: A retrospective study was made on hospitalized horses that had both plasma iron and fibrinogen concentrations measured on hospital admission.Results: Plasma iron concentration was lower in horses with systemic inflammation (64 +/- 45 mu g/dL) than the reference interval minimum (105 mu g/dL) and were significantly lower (P = .001) than the value in a group of horses with local inflammation (123 +/- 45 mu g/dL) and in healthy transported horses (143 +/- 29 mu g/dL). Low plasma iron and high fibrinogen concentrations were both sensitive indicators of systemic inflammation in horses with sensitivity of 90 and 82%, respectively. There was a similar correlation between either continued decreases in iron concentration (R-sp of 0.239) or increases in fibrinogen concentration (R-sp of 0.280) during hospitalization and a worse prognosis.Conclusions and Clinical Importance: Measurement of plasma iron concentration better reflected acute inflammation than did fibrinogen concentration.
Resumo:
The generation of active chlorine on Ti/Sn(1-x)Ir (x) O-2 anodes, with different compositions of Ir (x = 0.01, 0.05, 0.10 and 0.30 ), was investigated by controlled current density electrolysis. Using a low concentration of chloride ions (0.05 mol L-1) and a low current density (5 mA cm(-2)) it was possible to produce up to 60 mg L-1 of active chlorine on a Ti/Sn0.99Ir0.01O2 anode. The feasibility of the discoloration of a textile acid azo dye, acid red 29 dye (C.I. 16570), was also investigated with in situ electrogenerated active chlorine on Ti/Sn(1-x)Ir (x) O-2 anodes. The best conditions for 100% discoloration and maximum degradation (70% TOC reduction) were found to be: NaCl pH 4, 25 mA cm(-2) and 6 h of electrolysis. It is suggested that active chlorine generation and/or powerful oxidants such as chlorine radicals and hydroxyl radicals are responsible for promoting faster dye degradation. Rate constants calculated from color decay versus time reveal a zero order reaction at dye concentrations up to 1.0 x 10(-4) mol L-1. Effects of other electrolytes, dye concentration and applied density currents also have been investigated and are discussed.
Resumo:
This study reports the photodegradation of 4-chlorophenol (4-CP) in aqueous solution by the photo-Fenton process using solar irradiation. The influence of solution path length, and Fe(NO3)(3) and H2O2 concentrations on the degradation of 4-CP is evaluated by response surface methodology. The degradation process was monitored by the removal of total organic carbon (TOC) and the release of chloride ion. The results showed a very important role of iron concentration either for TOC removal or dechlorination. on the other hand, a negative effect of increasing solution path length on mineralization was observed, which can be compensated by increasing the iron concentration. This permits an adjustment of the iron concentration according to the irradiation exposure area and path length (depth of a tank reactor). Under optimum conditions of 1.5 mM Fe(NO3)(3), 20.0 mM H2O2 and 4.5 cm solution path length, 17 min irradiation under solar light were sufficient to reduce a 72 mg C L-1 solution of 4-CP by 91 (c) 2006 Elsevier B.V. All rights reserved.