160 resultados para Digestor Anaeróbio


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The anaerobic treatment of sewage is widely employed in Brazil and it is an appreciated way for the treatment of effluents, helping to reduce the environmental impact in rivers. The methane gas obtained from the process can be applied to improve the energetic efficiency of the system, reducing the amount of waste and the cost of the treatment process. This work presents the net energy balance of anaerobic reactors applied to the treatment of sewage. The analysis was performed considering full-scale and laboratory-scale treatment systems. In laboratory scale, the results from three kinds of systems were compared regarding the biological treatment of greywater. Two of them (UASB7 and UASB12) were anaerobic and the other one was a combined anaerobic-aerobic system (UASB7/SBR6). Greywater methanization (compared to theoretical maximum) was calculated considering 100% removal (g BOD/day), the literature percentage removal and the anionic surfactant presence in the effluentt. For each of these three cases, the efficiencies were, respectively, 16.9%, 43.6% and 51.3% in UASB7 reactor, 25.6%, 50.3% and 59.2% in UASB12 reactor and 30.6%, 61.2% and 71.9% in UASB7/SBR6 reactor. The energetic potential was found to be 4.66x10-4, 7.77x10-4 and 5.12x10-4 kWh/L for the UASB7, UASB12 and UASB7/SBR6 reactors, respectively. The pumping system, the aeration (in the anaerobic-aerobic system) and the temperature controlled heating system were considered to calculate the energetic consumption. However, the third one was not employed since tropical regions like Brazil do not need heating systems and also because of its high energetic consumption. The calculated net energy balance in the reactors was negative in the case of greywater, respectively -0.16, -0.28 and -0.18 kWh/L for the reactors UASB7, UASB12 and UASB7/SRB6. In full scale (ETE Jardim das Flores - Rio Claro, SP), the average energy... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The application of microwave radiation on the sample preparation has been expanding increasingly in areas involving decomposition by wet and dry roads, fusion, extraction, acceleration of chemical reactions, for example. Currently, the use of microwave ovens for analytical purposes are recognized for having excellent performance for organic and inorganic samples. In the international market there are several kinds of microwaves oven which adapt the varied purposes, however yet with elevated prices which incapacitate your use as routine equipment in laboratory. Thus, many researchers have been choosing for developing own projects of microwaves oven production or to use domestic oven for the laboratory, with or without adaptations. For the evaluation of the proposed method was used in the Kjeldahl methodology for determining total nitrogen in samples of crude protein, using a domestic microwave oven and a digester pot made up in TeflonTM and distillation by steam. Were made to adapt and characterization of a domestic microwave oven, the confeccion vessel digester and the metal support for the vessel. The accuracy of the proposed method was confirmed by comparison of two methods, the standard method for conventional heating and by the proposed method, with heating by microwave radiation through the calculated values of relative standard deviation analysis

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to analyze the influence of previous exercise on the determination of critical power (CP). Seven apparently healthy nontrained males, of 18 to 25 years, participated of this study. The subjects were submitted, in different days to the following protocols in a cyclergometer: 1) one progressive test until voluntary exhaustion for the determination of lactate threshold (LL), maximal oxygen uptake (VO2max) and its corresponding intensity (IVO2max); 2) six constant workload tests at 95,100 and 110% IVO2max until exhaustion with and without a previous exercise at 70% , in random order. The exhaustion times (tlim) at 95, 100 and 110% IVO2max were adjusted forme thress models of two parameters to estimate CP and anaerobic work capacity (AWC) [P=CTAn/tlim)+CP; tlim = CTAn/(P-PC); P=PC.tlim+ CTAn]. The model with the lowest standard error was considered for the estimation of CP. The tlim at 95% IVO2max was similar without (501 ± 140 s) and with previous exercise (473 ± 99 s). However, the tlim at 100% (381 ± 103 s and 334 ± 101 s) and 110% IVO2max (267 ± 163 s and 227 ± 68 s) was significantly longer with previous exercise. There was no significant difference in CP and AWCat conditions without (200 ± 27 W and 23 ± 11 kJ, respectively) and with previous exercise (212 ± 30 W and 18 ± 8 kJ, respectively). It can be concluded that the parameters of the relationship between power and time were not modified by the previous severe exercise

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project aimed to analyze the feasibility of the methane yield associated to the anaerobic digestion of brewery residues, checking whether the energetic balance of the system is favorable. The methane yield efficiency was calculated for the parameters of two papers that treated solids with a particle-size <1mm. Theses solids are not degraded in conventional treatment systems. Calculations were based in the reactions of anaerobic degradation of the macromolecules that compose brewery residues, considering the theoretical production and the effective production of methane. The results were 50.44% and 52.86%. Regarding to the energy balance of the anaerobic treatment, we noted the high influence of the selection and operating regime of electrical equipment over the potential energy. The best situation, in which the energetic self-sufficiency was reached, was observed when using the mixer under an intermittent regime (1min/h), without employing the heating recirculator, for the maximum organic loading of 4.0 gVS/L.day (days 248-258). In this case, the system would generate an amount of energy equal to 0.0356 kWh/day, able to overcome the energy required by the equipment in about 6.5 times. Moreover, we also noted the interference of the application of different solid loadings in the reactors, once the application of the higher organic load generated 5 times more energy than the application of the smaller one

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: O futsal é uma modalidade esportiva altamente dinâmica e sua prática em nível de rendimento é caracterizada por uma exigência altíssima dos sistemas anaeróbio e aeróbio, sendo o último, responsável por sustentar as altas intensidades exigidas durante a partida. Um exemplo de teste para avaliar a capacidade aeróbia é o “Circuito de Hoff”, porém específico para o futebol. Com a finalidade de elaborar um protocolo de teste específico para o futsal, este estudo procura padronizar o teste “Circuito de Hoff” como uma forma i ndireta de i nvestigar a capacidade aeróbia de atletas dessa modalidade. Objetivo: Padroni zar o “Circuito de Hoff” para avaliação da capacidade aeróbia de jogadores de futsal, determinada pelo teste de lactato mínimo. Metodologia: Participaram do estudo 8 atletas de futsal do sexo masculino (idade: 21,75±2,05 anos) pertencentes a uma equipe universitária de competição do Estado de São Paulo. Inicialmente os participantes passaram por uma avaliação antropométrica e deram início ao um período de 5 dias de familiarização ao Hofffutsal e logo após então realizaram o teste de lactato mínimo no circuito Hofffutsal. Após 7 dias, teste de lactato mínimo no circuito Hofffutsal foi reaplicado para a verificação da reprodutibilidade (intra-teste). Para análise estatística de normalidade e homogeneidade dos dados foram utilizados os testes Shapiro-Wilks e Levene respectivamente. Para comparação dos resultados foi realizado o teste t de Student pareado e a correlação de Pearson (p<0,05). Resultados: O teste t de Student não encontrou diferenças estatísticas entre os valores de Lac_mín teste x Lac_min Re-teste, e R2 Teste X R2 Re-teste. Apresentou-se valores de 7,75±0,29 mmol/l de lactato mínimo e r2 de 0,94±0,09 para teste e um valor de 7,69±0,29 mmol/l de lactato mínimo ...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to compare the power corresponding to maximal lactate steady state determined through continuous (MLSSC) and intermittent protocol with active recovery (MLSSI). Ten trained male cyclists (25 ± 4 yr, 72.5 ± 10.6 kg, 178.5 ± 4.0 cm), performed the following tests on different days on a cycle ergometer: (1) incremental test in order to determine the anaerobic threshold (AT) and maximal power (Pmax); (2) two to five constant workload tests to determine MLSSC, and; 3) two to three constant workload tests to determine MLSSI, consisting on 8 x 4 minutes bouts interspersed by two minutes of active recovery at 50% Pmax (i.e., 46 min of exercise protocol). MLSS intensity was defined as the highest workload at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant workload. The workload corresponding to MLSSC (273.2 ± 21.4 W) was significantly lower than that corresponding to MLSSI (300.5 ± 23.9 W). With base on these data, it can be verified that the intermittent exercise mode utilized in this study, allows an increase of 10% approximately, in the exercise intensity corresponding to MLSS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A obesidade é um problema de saúde pública mundial e está fortemente associada à doença cardíaca isquêmica, aterosclerose, hipertensão arterial, entre outros problemas cardiovasculares. Na atualidade, o tratamento sugerido para as doenças cardiovasculares, comumente decorrentes da obesidade, consiste na diminuição da ingestão de gordura aliada à atividade física. Contudo, pouco se sabe quanto aos protocolos de treinamento mais adequados para a prevenção ou tratamento dessas doenças. O presente estudo objetivou analisar os efeitos do exercício físico na intensidade de 80% do limiar anaeróbio (LAn) sobre os aspectos bioquímicos cardíacos de ratos obesos. Para a indução da obesidade, os animais, a partir dos 90 dias de idade, foram mantidos com dieta hiperlipídica/hipercalórica (35% de gordura animal/vegetal) e os animais controles, mantidos com dieta balanceada (AIN-93M). Todos os animais pertencentes ao grupo treinado foram submetidos a testes de lactato mínimo para a identificação do limiar anaeróbio (LAn) durante exercício de natação, treinando desde os 28 dias de idade até aos 90 dias em intensidade equivalente a 80% do LAn 1 h/dia, 5 dias/semana. Depois dos 90 dias uma parte dos animais treinados interrompeu o treinamento ficando em observação até o final do experimento (150 dias de idade). Os demais animais permaneceram sedentários ao longo de todo o experimento. Foram analisados: peso corporal, tolerância à glicose e à insulina (TTGo e TTI), perfil lipídico sérico (colesterol total, triglicerídeos, AGL e HDL), concentrações séricas de glicose e insulina e alíquotas do ventrículo esquerdo foram retiradas para análise das concentrações de triglicerídeos, glicogênio, proteína/DNA e atividade lipogênica. Os animais tratados com dieta hiperlipídica tiveram aumento significativo no peso corporal, intolerância à glicose e resistência à insulina e o treinamento físico neutralizou tais...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Brazil has one of the largest cattle herds in the world, so the cattle slaughter is one of the most important economic activities in the Brazilian market. But this activity requires a high demand of water, resulting in serious problems about the correct disposal of wastewater generated in the process. This effluent has a high pollution load, becoming its receiving bodies (streams and rivers) unfit for various activities such as public water supply, recreation, fisheries. To minimize the environmental impacts of its industrial wastewater and fallow the local environmental legislation, refrigerators must make the treatment of these effluents. This study aimed to verify the efficiency of a enzymatic reactor, when occur hydrolysis of lipids present in the effluent industrial of an cattle slaughter industry. The treatment system used was composed of two separate reactors: one being the anaerobic fluidized bed reactor (AFBR), inoculated with immobilized enzymes on the matrix support, and the other by sequential batch reactor (SBR) inoculated with activated sludge. Whereas, the reactors have been developed and installed at the Wastewater Treatment Laboratory, Faculdade de Ciências e Tecnologia, UNESP, campus Presidente Prudente. The procedure operating occurred differently for each reactor: preparation and inoculation of enzyme granules, filling the reactor, hydrolysis, and AFBR emptying, filling, aerobic reaction, sedimentation, and emptying the SBR. We performed three experimental stages, with the first and second stage of the work were done reactor analyzes separately, and the third step of the analysis were made with the interconnected reactors... (Complete abstract electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to develop, implement and evaluate the performance of a new type of bioreactor for anaerobic treatment of wastewater using different filling materials like trickling filters post-reactor. This bioreactor has mixed characteristics of the UASB reactors and horizontal flow from the point of view of removal of BOD (Biochemical Oxygen Demand) ssed (settled solids), TS (Total Solids), SS (Suspended Solid), SD (Dissolved Solids) and turbidity. The experimental model consists of a bioreactor with a volume of 12 m³, 2/3 filled by fluidized bed and 1/3 for fixed. The fluidized bed is made of polystyrene plates used as a system percolation and compartmentalized trickling filters, where each compartment was filled with a support medium with different characteristics (gravel number 4, plastic rings of polystyrene, PET and HDPE) . In addition, the output of a filter system was installed three entries filled with activated carbon. The bioreactor was installed in private residence in the city of Igarapava-SP (20° 02'40.18"S and 47° 45'01.36" W). The system was highly efficient as the removal of organic contaminant load 92% on average reducing the BOD, a significant result when compared to other anaerobic systems. For the other parameters, the mean reduction was 96% for turbidity, 99% ssed, 67.5% ST, 57% SD and 88% of SS. As for its operation the system was capable of operating in continuous flow without the need for maintenance during the entire period of evaluation and without energy, as it operates taking advantage of the natural slope of the terrain where it is installed. The environmental impacts were minimized due to the preservation of local vegetation allowing the ecosystem to remain unchanged beyond the prototype was completely sealed preventing exhalation of odors and therefore not causing inconvenience to neighboring populations. Given these facts it was concluded that the prototype is shown to be highly feasible deployed as a new alternative for treatment of sewage in rural and urban settings (individual homes, condos, farms, ranches, etc.) Due to ease of design and operability, and sustainability at all stages of execution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exercise physiology has attempted to reproduce the experimental exercise in the laboratory using mainly rats. The swimming exercise has emerged as one of the leading research in these type ergometers. Thus, this research consisted of a literature review addressing the key issues which involve the exercise of swimming in the model rats. Training of aerobic and anaerobic swimming, evaluation models and models of periodization were the topics suggested in this research. In several studies, models of aerobic and anaerobic training have been proposed with the aim of studying their effect on normal and abnormal physiological parameters. However, earlier studies lacked methods of analysis aiming to determine the exercise intensity in the animal model. For this reason, in the last decade, assessment models have been adapted for humans to animals, especially rats. The maximal lactate steady state (MLSS) and lactate minimum (LM) are among the various techniques used to measure the amount of effort produced by swimming exercise in rats. Thereafter, based on biochemical parameters such as lactate, swimming exercise in rats has become the highest-rated, ie, using as reference the anaerobic threshold (AT). In another aspect, an entirely new line of research has tried to understand and promising swimming training in a periodized and its effects on some biochemical parameters. But this is an area little researched so far. Thus, the experimental model of swimming has proved an important resource of exercise physiology. From this model, it becomes possible to study the exercise, especially swimming, in more accurate, based on invasive and incisive analysis of the rat