143 resultados para Calibração de camêra
Resumo:
The purpose of a water treatment plant (WTP) is to provide quality water to the population in the municipality where it is operate, being directly linked to the health of the community. The efficiency of a water treatment is directly related to the quality and reliability of the methods used. The analytical results of any laboratory test or calibration is a critical process for any company today. A tool used to assist in a quality management system process is ISO/IEC 17025:2005. Given the above, the objective of this study was to evaluate the performance of an ETA located in Lençóis Paulista-SP, using the analytical results obtained by physical, chemical and microbiological determinations in the period 1-30 October 2015. Such determinations are grounded in compliance with current Ordinance 2914 the Ministry of Health and the Quality Management System, which is required for all laboratories carrying out laboratory tests for control and surveillance of water quality for human consumption
Resumo:
The aim of this study was to evaluate the quality of weight measurements produced in Primary Health Care Centers in Botucatu and surroundings. 14 Health Care Centers were included, all of them located in four towns in the area of Botucatu (4,555; 5,656; 18,761 and 128,397 inhabitants). General conditions and scale calibration conditions found in those Health Care Centers were evaluated. In order to evaluate the weight accuracy obtained by the local team, 10 adult users of each Center were addressed by the rater during the service routine in order to get a new weight evaluation, immediately after the measurement made by the team. The statistic method applied for checking the weight measurement held in the Heath Care Center and the scales accuracy was the measurement error technique (MET). The results have showed that out of 19 scales, 6 of them overestimated the weight by 50 grams, 1 of them underestimated the weight by 200 grams and the others were accurate. Evaluated as a group, the result of the scale MET was 44.3g. Regarding the conformity of the measures obtained by the MET of the adults weighing in the Health Care Centers compared to the ones obtained by the researcher, the expected result was obtained in only one Center (< 100g). The results have showed data compromise, rather due to lack of health team training than due to the conditions of the equipment used for the measurement.
Resumo:
The aim of this study was to evaluate the evolution of calibration and maintenance practices for crop sprayers on soybean production areas in Brazil, in the 2006 and 2007 seasons, based on the Project IPP data. Therefore, the evaluation covered issues related to calibration, maintenance condition and the main components of 103 sprayers distributed in the following states: Rio Grande do Sul (35), Paraná (60), and, Mato Grosso do Sul (8). The evaluations were done at the rate of one sprayer per farm. The most frequent problems were related to the pressure gauge, spray leaks and calibration errors greater than 50% of the desired volume rate. The analysis of the application rate showed a tendency for the farmers to apply volume rates below the desired value. In 2006 the errors of the application rate were significant, with 70.4% for Rio Grande do Sul State, 74.5% for Paraná State and 37.5% for Mato Grosso do Sul State. In 2007 there was a reduction of errors, with averages of 50.0% for Rio Grande do Sul and 66.7% for Paraná. In general terms, the results showed improvements on the use, maintenance and calibration processes for crop sprayers on the areas covered by the Project IPP, with reductions on average indexes for calibration errors, leaks and bad tips, among other issues.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Educação Matemática - IGCE
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)