242 resultados para CAMARA DE LECHO FLUIDO
Resumo:
This randomized clinical trial sought to evaluate the performance of two packable composites over a period of 36 months. A total of 39 Class I and II restorations were placed in the permanent teeth of 20 patients. Using United States Public Health Services criteria, two investigators evaluated the restorations immediately after placement and again after 12 and 36 months, examining color match, marginal discoloration, marginal integrity, recurrent caries, proximal contact, anatomical shape, surface texture, and postoperative sensitivity. It was concluded that the packable composites evaluated showed satisfactory clinical performance after three years.
Resumo:
This study compared the color fidelity of different composite resins with their registration in the Vita Classical Shade Guide. Using a prefabricated Teflon mold, 120 specimens were divided into four groups fn - 30), according to the resin tested. Three subgroups (a = 10) were prepared for each resin group; these subgroups tested enamel shade, dentin shade, and enamel and dentin shade. Three measurements were performed to verily whether the tooth shade matched that of the Vita Classical Shade Guide. The color was evaluated and the shade variations were calculated. The data were submitted to a three-way AN OVA test (time, color match, and composite type), followed by Tukey's test. It was concluded that all composite resins showed color differences in relation to the Vita Classical Shade Guide.
Resumo:
Aim: This study evaluated the prevalence of the chewing side preference (CSP) in the deciduous, mixed and permanent dentitions. Materials and methods: Three-hundred subjects were divided in three groups (n = 100): Group 1 - children with deciduous dentition; group 2-children with mixed dentition; group 3 - subjects with permanent dentition. The CSP was determined using a direct method (visual observation) developed by McDonnell et al. (2004). Descriptive statistic was used to observe the prevalence of CSP. The Pearson's Chi-square was used to investigate signicant associations between gender, presence of CSP and preferred side (right/left). Results and conclusion: Eighty-seven percent of group 1 had a CSP. Eighty-two percent of group 2 had a CSP. Seventy-six percent of group 3 had a CSP. There was no statistically significant association between presence of CSP and gender in all groups. There was no statistically significant association between preferred side (right/left) and gender in all groups. Clinical significance: There is a higher prevalence of subjects in deciduous, mixed and permanent dentition that presented chewing side preference. The early diagnosis of the presence of chewing side preference can prevent the unilateral chewing pattern with prophylactic therapy applied to the first teeth (deciduous).
Resumo:
This article presents a case report of autogenous tooth transplantation to the site of the fissure, in addition to bone augmentation with graft of autogenous bone harvested from the iliac crest, performed in a cleft palate patient, who had insufficient bone volume. A non-syndromic 10-year-old girl, with a unilateral cleft lip and palate, incisal transforamen fissures, agenesis of the maxillary left central incisor and both maxillary lateral incisors, was treated with autogenous bone graft in the cleft area. The orthodontic treatment plan was to replace the missing lateral incisors with the maxillary canines and to extract the mandibular first premolars. One of the mandibular premolars was extracted from its site with 2/3 of its root formation completed and transplanted to the maxillary left central incisor area. After orthodontic treatment, the anatomic crowns were characterized with composite resin. Autogenous tooth transplantation can be performed in the area of the fissure in young cleft palate patients, by performing bone graft augmentation before transplantation of the tooth, to gain sufficient recipient alveolar bone volume. A multidisciplinary approach is mandatory for the success of this clinical procedure, especially in cleft palate patients. © 2012 John Wiley & Sons A/S.
Resumo:
In the majority of cases of bone fracture requiring surgery, orthopedic implants (screw-plate and screw) are used for osteosynthesis and the infections associated with such implants are due to the growth of microorganisms in biofilms. The objective of this study was to identify microorganisms recovered from osteosynthesis implants used to fix bone fractures, to assess the viability of the cells and the ability of staphylococci to adhere to a substrate and to determine their sensitivity/resistance to antimicrobials. After surgical removal, the metal parts of austenitic stainless steel (ASTM F138/F139 or ISO NBR 5832-1/9) were transported to the Laboratory of Clinical Microbiology, washed in buffer and subjected to ultrasonic bath at 40±2 kHz for 5 minutes. The sonicated fluid was used to seed solid culture media and cell viability was assessed under the microscope by with the aid of a fluorescent marker. The production of extracellular polysaccharide by Staphylococcus spp. was investigated by means of adhesion to a polystyrene plate. The profile of susceptibility to antimicrobials was determined by the disk diffusion assay. The most frequently isolated bacteria included coagulase-negative Staphylococcus resistant to erythromycin, clindamycin and oxacillin. Less frequent were Pseudomonas aeruginosa resistant to trimethoprim/sulfamethoxazole and ampicillin, Acinetobacter baumannii resistant to ceftazidime, Enterobacter cloacae resistant to cephalothin, cefoxitin, cefazolin, levofloxacin and ciprofloxacin, Bacillus spp. and Candida tropicalis. The observation of slides by fluorescence microscope showed clusters of living cells embedded in a transparent matrix. The test for adherence of coagulase-negative Staphylococcus to a polystyrene plate showed that these microorganisms produce extracellular polysaccharide. In conclusion, the metal parts were colonized by bacteria related to orthopedic implant infection, which were resistant to multiple antibiotics.
Resumo:
Aim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Results and conclusion: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Clinical significance: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.
Resumo:
Objective: We evaluated whether chronic exposure to immunosuppression in transplant recipients modulate the placental inflammatory cytokine levels associated to gestational tolerance mechanisms. Methods: Serum samples were collected from 12 renal transplanted pregnant under immunosuppressive regimen treatment and 10 healthy women in second/third trimester of gestation. Term placental tissues (decidua and chorionic villi) were also obtained after elective caesarean. Serum IL-1β, IL-6, IL-8, IL-12p70 and TNF-α were measured, as also in placental homogenates, by Cytometric Bead Array (CBA) combined with flow cytometry and, TGF-β and IL-18 were measured by ELISA. Results: Serum levels of IL-6 (p=0.0001) and TNF-α (0.0112) were higher in the 2nd and 3rd trimesters and in decidua the spectrum of increased pro inflammatory cytokines was wider: IL-1β (p=0.0001), IL-6 (p=0.0001), IL-8 (p=0.0001), IL-12p70 (p=0.0001), TGF-β (p=0.0089) and TNF-α (p=0.0002). TGF-β1 was particularly increased in decidual compartment (p=0.001). In the chorionic villous, pro inflammatory profile also were maintained. High IL-1β (p=0.0001), IL-6 (p=0.0001), IL-8 (p=0.0001) and TNF-α (p=0.0001) levels establish a similar pattern to that seem in decidua. Conclusion: Immunosuppressors may impair the immune response, but when associated with pregnancy the cytokine levels seems to shift a proinflammatory profile in placental compartments, which might also impact on the gestational outcomes in transplanted mothers. © 2013 Informa UK Ltd. All rights reserved: reproduction in whole or part not permitted.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)