21 resultados para visual detection
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The general statement that birds are recorded more often on morning than on afternoon counts is quite common and widespread among ornithologists. Although many investigators have reported temporal variations in bird detections using Point Counts in temperate regions, few researches regarding the same objectives have been conducted in Neotropical habitats or used transect counts as field method. We used transect counts to test the hypothesis that birds are evenly recorded between times of day in a predominantly open Cerrado landscape in southeastern Brazil. Although not always significantly, the number of species and individuals were consistently greater during the morning counts, which corroborates the fact that birds can be more detectable during this time of day. However, a few families as well as a small percentage of species were more likely to be recorded during either one of the two periods we analyzed. Our results suggest that morning counts should detect higher number of both species and individuals in our study area, but specific taxa show distinct patterns of detection which should be acknowledged prior to sampling.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The routine methods for detecting Listeria sp. in foods are time consuming and involve using selective enrichments and plating on agars. In this study, the presence of Listeria sp. in 120 meat and meat product samples was investigated by two rapid immunoassays (TECRA Listeria Visual Immunoassay [VIA] and BioControl Visual Immunoprecipitate Assay [VIP] for Listeria) and a cultural procedure. The cultural method of detecting Listeria sp. followed Canada's Health Protection Branch Method, and the rapid tests followed the manufacturers' instructions. The agreement between the cultural and the rapid tests was established at a confidence limit of 95%. Seventy-nine samples (65.8%) were Listeria sp. positive in at least one of the three tests. There was no statistically significant difference between the cultural procedure and any of the rapid immunoassays. The agreement rates between the VIA and the cultural method and between the VIP and the cultural method were 87 and 84%, respectively. Both tests - the VIA and VIP - proved to be rapid, efficient and easy to perform.
Resumo:
Ornamental fish may be severely affected by a stressful environment. Stressors impair the immune response, reproduction and growth rate; thus, the identification of possible stressors will aid to improve the overall quality of ornamental fish. The aim of this study was to determine whole-body cortisol of adult zebrafish, Danio rerio, following visual or direct contact with a predator species. Zebrafish were distributed in three groups: the first group, which consisted of zebrafish reared completely isolated of the predator, was considered the negative control; the second group, in which the predator, Parachromis managuensis was stocked together with zebrafish, was considered the positive control; the third group consisted of zebrafish stocked in a glass aquarium, with direct visual contact with the predator. The mean whole-body cortisol concentration in zebrafish from the negative control was 6.78 +/- 1.12 ng g(-1), a concentration statistically lower than that found in zebrafish having visual contact with the predator (9.26 +/- 0.88 ng g(-1)) which, in turn, was statistically lower than the mean whole-body cortisol of the positive control group (12.35 +/- 1.59 ng g(-1)). The higher whole-body cortisol concentration found in fish from the positive control can be attributed to the detection, by the zebrafish, of relevant risk situations that may involve a combination of chemical, olfactory and visual cues. One of the functions of elevated cortisol is to mobilize energy from body resources to cope with stress. The elevation of whole-body cortisol in fish subjected to visual contact with the predator involves only the visual cue in the recognition of predation risk. We hypothesized that the zebrafish could recognize predator characteristics in P managuensis, such as length, shape, color and behavior. Nonetheless, the elevation of whole-body cortisol in zebrafish suggested that the visual contact of the predator may elicit a stress response in prey fish. This assertion has a strong practical application concerning the species distribution in ornamental fish markets in which prey species should not be allowed to see predator species. Minimizing visual contact between prey and predator fish may improve the quality, viability and welfare of small fish in ornamental fish markets. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.
Resumo:
The aim of this in vivo study was to evaluate the performance of laser fluorescence (LF) comparing different cut-off limits for occlusal caries detection. One hundred and thirty first permanent molars were selected. Visual examination and LF assessments were performed independently. The extent of caries was assessed after operative intervention. New cut-off limits were established and compared with those proposed by the manufacturer and by Lussi et al. (Eur J Oral Sci 109:14-19, 2001). Similar sensitivity and higher specificity was found at D(2) (considering as disease only dentin caries) when the LF cut-off limits proposed by Lussi et al. and the new one were compared. At the D(3) threshold (considering as disease only deep dentin caries), no statistically significant difference among the cut-off limits for sensitivity was found. However, the new cut-off limits showed higher specificity. The LF device provided good ability to detect dentin caries lesions. Furthermore, the new cut-off limits and the values proposed by Lussi et al. could be suggested for the in vivo detection of occlusal caries.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Purpose: The purpose of this study was to assess the influence of cleaning pits and fissures with on aluminum oxide air abrasion system on the detection of occlusal caries in primary teeth using laser fluorescence (LF) and visual examination. Methods. The sample comprised 65 pit and fissure sites on extracted primary teeth suspected to be carious. The sites were submitted to 2 visual examinations (examiner JAR) and 2 LF readings (examiner TMV). Next, the occlusal surfaces were air-abraded and re-examined thereafter using both methods. The teeth were sectioned, and the histological analysis of the sites with a stereoscopic magnifying lens at X32 magnification was used as the gold standard Results. Cohen's kappa statistic for LF and visual examination were, respectively, 0.282/0.884 before and 0.896/0.905 after air abrasion. LF showed a sensitivity of 0.28 increasing to 0.49 and 0 specificity of 0.50 increasing to 0.92. Visual examination showed sensitivity of 0.78 and specificity of 0.73. Both increased after air abrasion. Conclusion: The findings suggest that cleaning pits and fissures with aluminum oxide air abrasion increased the accuracy of LF and visual examination for detection of occlusal caries in primary teeth.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work involved the development of a smart system dedicated to surface burning detection in the grinding process through constant monitoring of the process by acoustic emission and electrical power signals. A program in Visual Basic® for Windows® was developed, which collects the signals through an analog-digital converter and further processes them using burning detection algorithms already known. Three other parameters are proposed here and a comparative study carried out. When burning occurs, the newly developed software program sends a control signal warning the operator or interrupting the process, and delivers process information via the Internet. Parallel to this, the user can also interfere in the process via Internet, changing parameters and/or monitoring the grinding process. The findings of a comparative study of the various parameters are also discussed here. Copyright © 2006 by ABCM.