164 resultados para tibial plato leveling osteotomy
Resumo:
The aim of this study was to clinically and radiographically evaluate acute bone shortening followed by gradual lengthening in the treatment of large segmental tibia defects induced in seven clinically normal dogs. A circular external fixator was assembled with one proximal 5/8-circle ring, one middle ring and one distal ring connected with three rods. Thirty per cent of the tibia and fibula were removed in the middle and distal parts of the diaphyses, between the middle and distal rings. Acute bone shortening with compression of proximal and distal segments was performed. A subperiosteal osteotomy was performed between the half-ring and middle ring. Bone distraction started 7 days after surgery; after lengthening, the apparatus was left in place for 14 weeks for consolidation of regenerated bone. The frame was removed at the end of this period, and the dogs observed for four more weeks. Functional results were considered excellent in two, good in three and fair in the other two dogs. Bone regeneration within the distraction gap was obtained 14 weeks after neutral fixation period. We concluded that acute bone shortening followed by gradual lengthening by Ilizarov method can be used to treat extensive tibial defects in dogs, although it presents limb temporary abnormal limb shape and unequal length as early disadvantages.
Modified stabilization method for the tibial tuberosity advancement technique: a biomechanical study
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Piezosurgery is an osteotomy system used in medical and dental surgery. Many studies have proven clinical advantages of piezosurgery in terms of quality of cut, maneuverability, ease of use, and safety. However, few investigations have tested its superiority over the traditional osteotomy systems in terms of dynamics of bone healing. Therefore, the aim of this study was to evaluate the dynamics of bone healing after osteotomies with piezosurgery and to compare them with those associated to traditional bone drilling.Methods: One hundred and ten rats were divided into two groups with 55 animals each. The animals were anesthetized and the tibiae were surgically exposed to create defects 2 mm in diameter by using piezosurgery (Piezo group) and conventional drilling (Drill group). Animals were sacrificed at 3, 7, 14, 30 and 60 days post-surgery. Bone samples were collected and processed for histological, histomorphometrical, immunohistochemical, and molecular analysis. The histological analysis was performed at all time points (n = 8) whereas the histomorphometrical analysis was performed at 7, 14, 30 and 60 days post-surgery (n = 8). The immunolabeling was performed to detect Vascular Endothelial Growth Factor (VEGF), Caspase-3 (CAS-3), Osteoprotegerin (OPG), Receptor Activator of Nuclear Factor kappa-B Ligand (RANKL), and Osteocalcin (OC) at 3, 7, and 14 days (n = 3). For the molecular analysis, animals were sacrificed at 3, 7 and 14 days, total RNA was collected, and quantification of the expression of 21 genes related to BMP signaling, Wnt signaling, inflammation, osteogenenic and apoptotic pathways was performed by qRT-PCR (n = 5).Results: Histologically and histomorphometrically, bone healing was similar in both groups with the exception of a slightly higher amount of newly formed bone observed at 30 days after piezosurgery (p < 0.05). Immunohistochemical and qRT-PCR analyses didn't detect significant differences in expression of all the proteins and most of the genes tested.Conclusions: Based on the results of our study we conclude that in a rat tibial bone defect model the bone healing dynamics after piezosurgery are comparable to those observed with conventional drilling. © 2013 Esteves et al.; licensee BioMed Central Ltd.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Excessive mechanical stress due to caudal sloping of the tibial plateau may result In early breakdown of the cranial cruciate ligament (CrCL). Five dogs with CrCL rupture associated with caudal sloping of the proximal tibial plateau are described. All were small dogs, of between three and six years of age, with a mean bodyweight of 9.3 kg, which had acute hindlimb lameness. Radiographic examination revealed cranial displacement of the tibia, with a tibial angle varying from 58 to 60 degrees. All cases were treated with a lateral fabellotibial suture and cranial cuneiform osteotomy of the proximal tibia. All dogs were using the operated limb three days after surgery, with normal gait re-established after a mean period of 10 days. Excessive tibial plateau sloping is not a frequent cause of hindlimb lameness In small animals, although it Is Important to consider it as a predisposing factor for rupture of the CrCL.
Resumo:
A discondroplasia tibial (DT) é atribuída a uma assincronia no processo de diferenciação dos condrócitos, levando à formação de uma camada de condrócitos pré-hipertróficos e de uma cartilagem na tíbia proximal que não é calcificada, mas é resistente à invasão vascular. Além disso, tem sido proposto que, na discondroplasia tíbial, a etapa final do processo de calcificação não ocorre devido ao fato de que os efetores de alguns genes, relacionados com o mecanismo de calcificação do disco de crescimento podem apresentar algumas de suas propriedades químicas ou biológicas alteradas e/ou não serem expressos. Nesse sentido, a compreensão do mecanismo de ação e o papel das biomoléculas e dos minerais relacionados com a discondroplasia tibial poderão contribuir para o conhecimento de doenças do tecido ósseo e estabelecer estratégias de prevenção e tratamento.
Resumo:
The aim of this study was to investigate the effect of high fat diet and different frequencies of swimming programs in the tibial anterior muscle in male Wistar rats. In conclussion, the aerobic training during two days/week and five days/week caused injuries in muscle fibers and the high fat diet did not cause statically significant results compared to normal diet.
Resumo:
Low level laser therapy (LLLT) is known for its positive results but studies on the biological and biomodulator characteristics of the effects produced in the skeletal muscle are Still lacking. In this Study the effects of two laser dosages, 5 or 10 J/cm(2), on the lesioned tibial muscle were compared. Gerbils previously lesioned by 100 g load impact were divided into three groups: GI (n = 5) controls, lesion non-irradiated; GII (n = 5), lesion irradiated with 5 J/Cm(2) and GIII (n = 5), lesion irradiated with 10 J/cm(2), and treated for 7 consecutive days with a laser He-Ne (lambda = 633 rim). After intracardiac perfusion, the muscles were dissected and reduced to small fragments, post-fixed in 1% osmium tetroxide, dehydrated in increasing alcohol concentrations, treated with propylene oxide and embedded in Spurr resin at 60 degrees C. Ultrafine Cuts examined on a transmission electron microscope (Jeol 1010) revealed in the control GI group a large number of altered Muscle fibers with degenerating mitochondria, intercellular substance containing degenerating cell fragments and budding blood capillaries with Underdeveloped endothelial cells. However, groups GII and GIII showed muscle fibers with few altered myofibrils, regularly contoured mitochondria, ample intermembrane spaces and dilated mitochondrial crests. The clean intercellular Substance showed numerous collagen fibers and capillaries with multiple abluminal processes, intraluminal protrusions and several pinocytic vesicles in endothelial cells. it was concluded that laser dosages of 5 or 10 J/cm(2) delivered by laser He-Ne (lambda = 633 rim) during 7 consecutive days increase mitochondrial activity in muscular fibers, activate fibroblasts and macrophages and stimulate angiogenesis, thus suggesting effectivity of laser therapy tinder these experimental conditions. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
This study was carried out at Faculdade de Medicina Veterinária e Zootecnia, UNESP, Botucatu-SP, Brazil. The aim was to establish the normal values of bone mineral density (BMD) expressed in millimeters of aluminum in the tibia of broiler chickens using optical densitometry of radiographs. Four hundred Cobb male chicks were reared from 1 to 40 days of age, when 40 of them were selected and the right femur-tibia articulation was radiographed. Radiographs were taken with the X-ray equipment calibrated for 45 kvp and 3.2 mAs and a focus-to-film distance of 90 cm. An aluminum phantom ASTM-6063 consisting of 20 ladder steps with graduate density was placed parallel to the area to be radiographed and used as a densitometry reference standard. Radiograph images were analyzed using the software ATHENA - SIA. The proximal growth plate of the right tibia epiphysis was used as the standard reading region. The inclination axis of the reading window was 0 and the window was 10 mm high and 40-45 mm wide, depending on the bone size. Optical densitometry values of the radiographs ranged from 1.46 to 1.77 mmAl, and the coefficient of variation was 9.93%. It was concluded that densitometry values beyond the range established in the present study might indicate the presence of bone alteration in the tibia of broilers.
Resumo:
This study was carried out at Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Botucatu, SP, Brazil, with the objective of evaluating the efficacy of four techniques in the assessment of tibial dyschondroplasia lesions in broiler chickens. Four hundred Cobb male chicks were reared from 1 to 39 days of age. At 39 days, forty birds were selected and tibial dyschondroplasia status was assessed by four different techniques: evaluation using the lixiscope, macroscopic examination, histological examination and bone mineral density assessment using optical radiographic densitometry. The efficacy of each technique to assess dyschondroplasia lesions in the tibial growth plate was determined in comparison to histology, which was considered to be 100% efficient. The correlation results between lixiscope analysis and histology were poor. Macroscopic scores and densitometry readings were highly correlated with histology scores, and it is considered that these techniques reliably reproduce the status of the growth plate.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Purpose: This study used bovine ribs to comparatively assess the deformation, roughness, and mass loss for 3 different types of surface treatments with burs, used in osteotomies, for the installation of osseointegrated implants.Materials and Methods: The study used 25 bovine ribs and 3 types of helical burs (2.0 mm and 3.0 mm) for osteotomies during implant placement (a steel bur [G1], a bur with tungsten carbide film coating in a carbon matrix [G2], and a zirconia bur [G3]), which were subdivided into 5 subgroups: 1, 2, 3, 4, and 5, corresponding to 0, 10, 20, 30, and 40 perforations, respectively. The surface roughness (mean roughness [Ra], partial roughness, and maximum roughness) and mass (in grams) of all the burs were measured, and the burs were analyzed in a scanning electron microscope before and after use. Data were tabulated and statistically analyzed by use of the Kruskal-Wallis test, and when a statistically significant difference was found, the Dunn test was used.Results: There was a loss of mass in all groups (G1, G2, and G3), and this loss was gradual, according to the number of perforations made (1, 2, 3, 4, and 5). However, this difference was not statistically significant (P < .05). Regarding the roughness, G3 presented an increase in Ra, partial roughness, and maximum roughness (P < .05) compared with G2 and an increase in Ra compared with G1. There was no statistically significant difference (P > .05) between G1 and G2. The scanning electron microscopy analysis found areas of deformation in all the 2.0-mm samples, with loss of substrates, and this characteristic was more frequent in G3.Conclusions: The 2.0-mm zirconia burs had a greater loss of substrates and abrasive wear in the cutting area. They also presented an increased roughness when compared with the steel and the tungsten carbide coating film in carbon matrix. There was no statistically significant difference (P < .05) between G1 and G2 in any mechanical test carried out. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:e608-e621, 2012
Resumo:
This study verified the resistance to displacement of six miniplate fixation methods after sagittal split osteotomy (SSO). SSO was performed in 30 polyurethane synthetic mandible replicas. The distal segments were advanced (4 mm) and specimens were grouped according to the fixation method: four-hole standard miniplate; four-hole locking miniplate; six-hole standard miniplate; six-hole locking miniplate; six-hole standard sagittal miniplate; six-hole locking sagittal miniplate. Biomechanical evaluation was performed by applying compression loads to three points on the second molar region, using an Instron universal testing machine until a 3 mm displacement of the segments occurred. Compression loads able to produce 3 mm displacement were recorded in kN and subjected to analysis of variance (P < 0.01) and Tukey's tests for comparison between groups (P < 0.05). The locking sagittal miniplate showed higher resistance to displacement than the regular four- and six-hole locking and standard miniplates. No significant differences were observed between the locking sagittal miniplate and the regular sagittal or the four-hole locking miniplates. Two of the three groups with the best results had locking plate fixation methods. Fixation of SSO with a single miniplate is better accomplished using six-hole locking sagittal miniplates, six-hole standard sagittal miniplates, or four-hole locking miniplates; these methods are more resistant to displacement.