59 resultados para serrated aperture
Resumo:
This work describes the use of a large-aperture PVDF receiver in the measurement of liquid density and composite material elastic constants. The density measurement of several liquids is obtained with accuracy of 0.2% using a conventional NDE emitter transducer and a 70-mm-diameter, 52-mu m P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants is based on the phase velocity measurement. Diffraction can lead to errors around 1% in velocity measurement when using alternatively the conventional pair of ultrasonic transducers (1-MHz frequency and 19-mm-diameter) operating in through-transmission mode, separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz, 19-mm-diameter transducers. Nevertheless, the dispersion at 10 MHz can result in errors of about 0.5%, when measuring the velocity in composite materials. The use of an 80-mm diameter, 52-mu m-thick PVDF membrane receiver practically eliminates the diffraction effects in phase velocity measurement. The elastic constants of a carbon fiber reinforced polymer were determined and compared with the values obtained by a tensile test. (C) 2009 Elsevier B. V. All rights reserved.
Resumo:
In this work, signal processing techniques are used to improve the quality of image based on multi-element synthetic aperture techniques. Using several apodization functions to obtain different side lobes distribution, a polarity function and a threshold criterium are used to develop an image compounding technique. The spatial diversity is increased using an additional array, which generates complementary information about the defects, improving the results of the proposed algorithm and producing high resolution and contrast images. The inspection of isotropic plate-like structures using linear arrays and Lamb waves is presented. Experimental results are shown for a 1-mm-thick isotropic aluminum plate with artificial defects using linear arrays formed by 30 piezoelectric elements, with the low dispersion symmetric mode S0 at the frequency of 330 kHz. © 2011 American Institute of Physics.
Resumo:
O objetivo deste trabalho foi determinar a posição e a profundidade de semeadura mais adequadas para a emergência de plântulas de açaizeiro. As sementes foram colocadas para germinar nas profundidades de 0; 3 e 6 cm e nas seguintes posições: sementes com a rafe perpendicular à superfície do substrato e poro germinativo para cima, rafe perpendicular e poro germinativo para baixo, rafe paralela à superfície e poro germinativo para baixo e rafe paralela à superfície e poro germinativo para cima. A emergência de plântulas de açaizeiro com a rafe perpendicular à superfície do substrato e poro germinativo para cima é a mais adequada, pois proporciona igual porcentagem e menor tempo médio de emergência. Profundidades iguais ou superiores a 3 cm são inadequadas para semeadura de Euterpe oleracea Mart.
Resumo:
O sistema tradicional para estimativas de safra utiliza-se de relatórios técnicos de fontes diversas. A coleta de informações, se inicia antes da época do plantio e as estimativas são vendo ajustadas de acordo com o desenvolvimento das culturas. O trabalho em questão, pretende mostrar as possibilidades do filme infravermelho colorido na estimativa de safra para a cultura do milho. As informações quantitativas foram obtidas através da densitometria de transmissão. Os trabalhos foram conduzidos na Fazenda Experimental São Manuel da Faculdade de Ciências Agronômicas - Campus de Botucatu - UNESP. Os seis tratamentos consistiram em doses diferenciais de adubo, prevendo prováveis quedas em produção. A cultura foi fotografada com filme colorido (Kodak Ektachrome 64 ASA) e infravermelho colorido (Kodak Ektachrome Infrared Film) e a densidade ótica medida em um microdensitômetro de transmissão marca Weston, modelo 877 e abertura de 0,8 mm. Para avaliar a interação entre Produção e Densidade Ótica, utilizou-se das análises de correlação e regressão linear. A análise dos resultados permitiram as seguintes conclusões principais: a) Desde que se faça as necessárias calibrações, o filme infravermelho pode ser utilizado na estimativa de safra para a cultura do milho; b) A utilização do densitômetro de transmissão, para a interpretação quantitativa dos resultados, revelou-se importante sugerindo a aplicação do método em outros tipos de culturas.
Resumo:
The purpose of this paper was to evaluate attributes derived from fully polarimetric PALSAR data to discriminate and map macrophyte species in the Amazon floodplain wetlands. Fieldwork was carried out almost simultaneously to the radar acquisition, and macrophyte biomass and morphological variables were measured in the field. Attributes were calculated from the covariance matrix [C] derived from the single-look complex data. Image attributes and macrophyte variables were compared and analyzed to investigate the sensitivity of the attributes for discriminating among species. Based on these analyses, a rule-based classification was applied to map macrophyte species. Other classification approaches were tested and compared to the rule-based method: a classification based on the Freeman-Durden and Cloude-Pottier decomposition models, a hybrid classification (Wishart classifier with the input classes based on the H/a plane), and a statistical-based classification (supervised classification using Wishart distance measures). The findings show that attributes derived from fully polarimetric L-band data have good potential for discriminating herbaceous plant species based on morphology and that estimation of plant biomass and productivity could be improved by using these polarimetric attributes.
Resumo:
Introduction and objectives: Catfish occur in marine and freshwater environments worldwide. They have three serrated venomous bony stings in the dorsal and pectoral fins that are used for defence against predators and are refilled by glandular tissues under the epithelium. However, some catfishes do not have poisonous glands next to the sting and cause traumatic wounds without poisoning. The objective of this study was to provide data for, and comment on, the epidemiological and clinical problems caused by marine catfish.Patients and methods: the authors have observed, followed and documented 127 injuries caused by marine catfish stings during different phases of the envenoming over a time period of 8 years at three points along the Western Atlantic Ocean coast.Results: the patients presented intense pain during the acute phase of envenoming and complications, such as bacterial and fungi infections and retention of bony fragments, in the later phase. Immersion of the affected extremity in hot water was used in about 20% of cases with excellent results.Discussion: Injuries caused by marine catfish are common (about 20% of injuries caused by marine animals in a series of more than 700 injuries recorded by the author) and cause intense pain and later complications. Immersion of the affected extremity in hot water results in improvement in the acute phase, but does not prevent the appearance of secondary infection or foreign body reactions. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
OBJECTIVES: To estimate oculometric parameters of Graves' ophthalmopathy in comparison to healthy eyes using digital photography and digital image analysis.INTRODUCTION: Graves' ophthalmopathy is the main cause of eye proptosis. Because these protrusions cause clinically perceived distortions in orbital architecture, digital photographs can be used to detect and quantify these changes.METHODS: We carried out a cross-sectional study comprising 12 healthy volunteers and 15 Graves' ophthalmopathy patients with the purpose of evaluating the use of simple, non-invasive digital photography to estimate oculometric parameters of Graves' ophthalmopathy and compare them with the parameters of unaffected eyes. Facial photographs of cases and controls were taken in a standardized manner. Oculometric parameters were compared between the groups and then correlated to proptometer measures.RESULTS: All estimated oculometric variables showed significant differences between the groups, in particular with regard to mediopupilar aperture, lateral height, distance from the iris edge to the lateral boundary of the palpebral fissure, and distance from the higher point of the iris to the lateral limit of the palpebral fissure. The product of medial aperture and horizontal palpebral fissure also revealed greater discrepancy between the groups. Proptometer measures showed significant linear correlation between the distance from the iris edge to the lateral boundary of the palpebral fissure and between the distance from the higher point of the iris to the lateral limit of palpebral fissure (p<0.05).CONCLUSIONS: Comparative analysis of oculometric parameters in Graves' ophthalmopathy suggests that eye proptosis is related to an asymmetric increase in lateral oculometric measures. Standardized digital photographs can be used in clinical practice to objectively estimate oculometric parameters of Graves' ophthalmopathy patients.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The objective of this study is to investigate the patterns of shell utilization in Petrochirus diogenes in the Ubatuba region, SP, Brazil. Hermit crabs were obtained from 1993 to 1996 with the aid of a shrimp fishery boat equipped with two double-rigged trawling nets. Shells were identified and weighed, and their maximum aperture width was measured. Hermit crabs were weighed, and their shield length was recorded. A total of 634 P. diogenes specimens, occupying shells of 12 gastropod species, was obtained. The shells of Tonna galea, Zidona dufresnei and Strombus pugilis were the most frequently occupied, the first marked by its larger aperture width and lower average weight. Small hermit crabs inhabited a wide variety of gastropod shells due to their higher availability. However, the utilization of T. galea shells became predominant as the crabs attained larger sizes. Differences in weight and aperture width are known to encourage certain shell utilization patterns and may affect growth and reproduction of hermit crabs.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Foi avaliado o possível efeito de tratamentos superficiais em pinos de fibra de carbono lisos, quando comparados aos pinos serrilhados, na retenção à resina composta empregada na confecção de núcleos de preenchimento. Foram utilizados cinqüenta pinos de fibra de carbono, divididos em cinco grupos: os quatro primeiros grupos eram constituídos por pinos do tipo liso, cujas superfícies foram tratadas, e o último grupo por dez pinos do tipo serrilhado. Foram desenvolvidas matrizes de resina acrílica com um leito ajustado para conter o pino, com um alargamento na porção coronária para posterior preenchimento com resina composta. Após o tratamento superficial, todos os pinos receberam camadas de primer, foram secos e então ajustados à matriz de resina, colocando-se a resina composta autopolimerizável na porção coronária para um núcleo de preenchimento de 3 mm. As amostras foram submetidas a termociclagem e armazenadas em água destilada por uma semana. Os espécimes foram testados por meio de ensaios mecânicos de tração, à velocidade de 0,5 mm/min, até o deslocamento do conjunto ou a fratura da resina do núcleo. As conclusões foram as seguintes: a) o tratamento superficial nos grupos tratados por meio de jateamento (Grupo A), pontas diamantadas marcadoras de profundidade para facetas laminadas (Grupo C) e alteração da morfologia da extremidade coronária (Grupo D) conferiu aos pinos lisos valores de retenção comparáveis aos dos pinos serrilhados (Grupo E) nos ensaios de tração, porém sem diferença estatisticamente significativa entre estes grupos; b) os pinos tratados por meio de pontas diamantadas de granulação média (Grupo B) obtiveram valores de retenção menores que os demais grupos.
Resumo:
Tungsten coil atomic emission spectrometry is an ideal technique for field applications because of its simplicity, low cost, low power requirement, and independence from cooling systems. A new, portable, compact design is reported here. The tungsten coil is extracted from an inexpensive 24 V, 250 W commercial light bulb. The coil is housed in a small, aluminum cell. The emission signal exits from a small aperture in the cell, while the bulk of the blackbody emission from the tungsten coil is blocked. The resulting spectra exhibit extremely low background signals. The atomization cell, a single lens, and a hand-held charge coupled device (CCD) spectrometer are fixed on a 1 x 6 x 30 cm ceramic base. The resulting system is robust and easily transported. A programmable, miniature 400 W solid-state constant current power supply controls the temperature of the coil. Fifteen elements are determined with the system (Ba, Cs, Li, Rb, Cr, Sr, Eu, Yb, Mn, Fe, Cu, Mg, V, Al, and Ga). The precision ranges from 4.3% to 8.4% relative standard deviation for repetitive measurements of the same solution. Detection limits are in the 0.04 to 1500 mu g/L range. Accuracy is tested using standard reference materials for polluted water, peach leaves, and tomato leaves. For those elements present above the detection limit, recoveries range from 72% to 147%.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)