669 resultados para radiographic zooming
Resumo:
Objectives: (1) To evaluate the intraobserver agreement related to image interpretation and (2) to compare the accuracy of 100%, 200% and 400% zoomed digital images in the detection of simulated periodontal bone defects.Methods: Periodontal bone defects were created in 60 pig hemi-mandibles with slow-speed burs 0.5 mm, 1.0 mm, 1.5 mm, 2.0 mm and 3.0 mm in diameter. 180 standardized digital radiographs were made using Schick sensor and evaluated at 100%, 200% and 400% zooming. The intraobserver agreement was estimated by Kappa statistic (kappa). For the evaluation of diagnostic accuracy receiver operating characteristic (ROC) analysis was performed followed by chi-square test to compare the areas under ROC curves according to each level of zooming.Results: For 100%, 200% and 400% zooming the intraobserver agreement was moderate (kappa = 0.48, kappa = 0.54 and kappa = 0.43, respectively) and there were similar performances in the discrimination capacity, with ROC areas of 0.8611 (95% CI: 0.7660-0.9562), 0.8600 (95% CI: 0.7659-0.9540), and 0.8368 (95% CI: 0.7346-0.9390), respectively, with no statistical significant differences (chi(2)-test; P = 0.8440).Conclusions: A moderate intraobserver agreement was observed in the classification of periodontal bone defects and the 100%, 200% and 400% zoomed digital images presented similar performances in the detection of periodontal bone defects.
Resumo:
Os achados clínicos e radiográficos após reparo intra-articular do ligamento cruzado cranial com prótese de poliéster, utilizando a técnica over-the-top modificada, foram avaliada em seis cães. Sete cirurgias foram realizadas devido ao acometimento bilateral em um dos animais. A avaliação clínica foi realizada ao 3º, 10º e 40º dias de pós-operatório, e a avaliação radiográfica realizada ao 5º e 24º meses após a cirurgia em cinco cães, por meio da qual se confirmou a progressão da doença articular degenerativa. A resolução dos sinais clínicos foi observada entre o 25º e 68º dias após a cirurgia, segundo avaliação realizada pelos proprietários. A função do membro operado foi considerada boa. Dois cães apresentaram desgaste e ruptura da prótese após a cirurgia. Concluiu-se que a prótese de poliéster, da forma como foi implantada neste estudo, não pode ser considerada como substituto satisfatório, uma vez que resultados superiores podem ser obtidos com ténicas menos invasivas e mais simples.
Resumo:
Doria, R.G.S.; Canola, P.A.; Freitas, S.H. & Canola, J.C. [Equine chronic proliferative synovitis (villonodular synovitis): clinical, radiographic and ultrasonographic aspects: Relate of case.] Sinovite proliferativa cronica (sinovite vilonodular) em equino: aspectos clinicos, radiograficos e ultra-sonograficos: Relato de caso. Revista Brasileira de Medicina Veterinciria 30(3):157-161, 2008. Departamento de Cirurgia, Faculdade de Medicina Veterinaria, Universidade de Cuiaba, UNIC, Av. Antartica 788, Casa 26, Residencial Villas Boas, Ribeirao da Ponte, Cuiaba, MT 78040-500. Brasil. E-mail: redoria@uol.com.brThe development of intracapsullar masses at the dorsal aspect of the metacarpofalangeal joint for a period of several months is commonly secondary to the chronic synovitis. Although it is known as villonodular synovitis in horses probably is better to refer it as chronic proliferative synovitis. The most common causes are the non-treated osteocondral fractures of the dorsal portion of the proximal phalanx. In addition, the development of villonodular masses follows the degenerative process in the joint. A case of a lame animal is reported at the present study. The correct diagnosis and the adequate therapeutic propositions were given based on the clinical examination, therapeutic local-anesthetic test and radioghaphic and ultrasonographic imaging exams. The development of a criterious identification of this disease must be based on clinical findings, radiographic and ultrasonographic exams which assume fundamental importance to the treatment and prognostic. The aim of this study is to describe the clinical, radiographic and ultrasonographic findings' allowing the identification and diagnosis of chronic proliferative synovitis at the thoracic metacarpofalangeal joint in the horse.
Resumo:
We present the construction of a homogeneous phantom to be used in simulating the scattering and absorption of X-rays by a standard patient chest and skull when irradiated laterally. This phantom consisted of Incite and aluminium plates with their thickness determined by a tomographic exploratory method applied to the anthropomorphic phantom. Using this phantom, an optimized radiographic technique was established for chest and skull of standard sized patient in lateral view. Images generated with this optimized technique demonstrated improved image quality and reduced radiation doses. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Em 12 fêmeas e 12 machos da raça Puro Sangue Inglês com idade média de 12 meses, avaliou-se os valores normais da densidade mineral óssea do carpo acessório em milímetros de alumínio (mmAl) até o momento do fechamento completo da epífise distal do rádio, por meio do método de densitometria óptica em imagens radiográficas. A avaliação foi realizada por meio de um programa computacional (software) especialmente desenvolvido para medida de densidade óptica em filmes de raios-X, o qual contém a imagem radiográfica do osso carpo acessório, região de partes moles adjacente ao carpo acessório e os degraus de uma escala de alumínio (phatom), que permitiu a medida de densidade mineral óssea, sendo esta a média aritmética da região de interesse determinada no osso carpo acessório correspondente ao valor em milímetros da escala. Os valores da densidade mineral óssea em mmAl do acessório do carpo em função da idade não apresentaram diferenças entre os sexos (p=0,86) permitindo que uma equação de reta fosse ajustada para ambos os sexos (densidade mineral óssea (DMO) mmAl = 3.109 + 0,056 x idade em meses), na faixa etária estudada.
Resumo:
Barrel racing is one of the most popular uses of the American Quarter horse in North and South America. Although injury to the metacarpophalangeal joint frequently occurs in this sport, there is limited information describing the nature of these injuries. The aim of this study was to determine the most common radiographic abnormalities in barrel racing horses with lameness referable to the metacarpophalangeal joint. lameness examinations were performed on 63 barrel racing horses. Those found to be lame were subjected to radiographic examination. Lameness at trot was scored on a scale of 0-5 (0 = sound; 5 = inability to move). Data were analyzed using descriptive statistical analysis. of horses examined, 30 (47.6%) were lame with scores ranging from 1 to 4. Half of the lame horses (15 of 30) had grade 2 lameness of the right forelimb. Abnormal radiographic findings were more often present on the left forelimb and included signs of sesamoiditis (70%), villonodular synovitis (56.6%), osteoarthritis (36.6%), osteochondritis dissecans (13.3%), capsulitis (13.3%), and soft-tissue swelling (6.6%). Radiographic abnormalities indicated that sesamoiditis, villonodular synovitis, and osteoarthritis may be associated to mild-to-moderate lameness in barrel racing horses. Complementary sonographic evaluation is recommended to better characterize soft-tissue abnormalities. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The vertical location of the implant-abutment connection influences the subsequent reaction of the peri-implant bone. It is not known, however, whether any additional influence is exerted by different microgap configurations. Therefore, the radiographic bone reactions of two different implant systems were monitored for 6 months. Materials and Methods: In eight mongrel dogs, two implants with an internal Morse-taper connection (INT group) were placed on one side of the mandible; the contralateral side received two implants with an external-hex connection (EXT group). on each side, one implant was aligned at the bone level (equicrestal) and the second implant was placed 1.5 mm subcrestal. Healing abutments were placed 3 months after submerged healing, and the implants were maintained for another 3 months without prosthetic loading. At implant placement and after 1, 2, 3, 4, 5, and 6 months, standardized radiographs were obtained, and peri-implant bone levels were measured with regard to microgap location and evaluated statistically. Results: All implants osseointegrated clinically and radiographically. The overall mean bone loss was 0.68 +/- 0.59 mm in the equicrestal INT group, 1.32 +/- 0.49 mm in the equicrestal EXT group, 0.76 +/- 0.49 mm in the subcrestal INT group, and 1.88 +/- 0.81 mm in the subcrestal EXT group. The differences between the INT and EXT groups were statistically significant (paired t tests). The first significant differences between the internal and external groups were seen at month 1 in the subcrestal groups and at 3 months in the equicrestal groups. Bone loss was most pronounced in the subcrestal EXT group. Conclusions: Within the limits of this study, different microgap configurations can cause different amounts of bone loss, even before prosthetic loading. Subcrestal placement of a butt-joint microgap design may lead to more pronounced radiographic bone loss. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:941-946
Resumo:
Purpose: The aim of this study was to evaluate by means of digital radiography the behavior of the alveolar bone crest in external hexagon implants following the use of 2 different types of abutments, one for conventional cemented prosthesis and one for modified cemented prosthesis.Methods: Ten external hexagon implants (platform 4.1) were placed in 5 patients. Initial instrumentation was carried out to obtain primary stability of the temporary prostheses under immediate loading. Each patient received both abutments for conventional and modified cemented prosthesis. Standardized digital periapical radiographies were performed at times T0 (immediately after implant placement) and T1 (4 months after implant placement). A straight line was initially established from the implant platform to the distal and mesial periimplantar marginal bone tissue (immediately in contact with the implant) and measured by digital radiography, using Sidexis version 2.3 (Sirona Dental Systems GmbH, Bensheim, Germany) software. The data were submitted to paired-samples t-test analysis.Results: There was no significant difference between the conventional and modified cemented prosthesis. In both cases, t-test results were within the null hypothesis level.Conclusion: The abutment for the modified cemented prosthesis resulted in no significant radiographic difference of alveolar bone crest height, when compared with the conventional cemented prostheses.
Resumo:
Purpose: The implant-abutment connection (microgap) influences the pen-implant bone morphology. However, it is unclear if different microgap configurations additionally modify bone reactions. This preliminary study aimed to radiographically monitor pen-implant bone levels in two different microgap configurations during 3 months of nonsubmerged healing. Materials and Methods: Six dogs received two implants with internal Morse taper connection (INT group) on one side of the mandible and two implants with external-hex connection (EXT group) on the other side. One implant on each side was positioned at bone level (equicrestal); the second implant was inserted 1.5 mm below the bone crest (subcrestal). Healing abutments were attached directly after implant insertion, and the implants were maintained for 3 months without prosthetic loading. At implant placement and 1, 2, and 3 months, standardized radiographs were taken to monitor pen-implant bone levels. Results: All implants osseointegrated. A total bone loss of 0.48 +/- 0.66 mm was measured in the equicrestal INT group, 0.69 +/- 0.43 mm in the equicrestal EXT group, 0.79 +/- 0.93 mm in the subcrestal INT group, and 1.56 +/- 0.53 mm in the subcrestal EXT group (P>.05, paired t tests). Within the four groups, bone loss over time became significantly greater in the EXT groups than in the INT groups. The greatest bone loss was noted in the subcrestal EXT group. Conclusion: Within the limits of this animal study, it seems that even without prosthetic loading, different microgap configurations exhibit different patterns of bone loss during nonsubmerged healing. Subcrestal positioning of an external butt joint microgap may lead to faster radiographic bone loss. Int J Prosthodont 2011;24:445-452.