299 resultados para hydroxyapatite implants


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was nondecalcified histologic analysis of titanium implants modified by laser with and without hydroxyapatite. Implants with three modified surfaces were inserted into rabbit tibias: group 1, machined surface; group 2, irradiated (laser); and group 3, irradiated and hydroxyapatite coated (biomimetic method). The mean surface roughness (Ra) scores of groups 2 and 3 were higher than that of group 1. Bone-implant contact measurements at 30 and 60 days for groups 2 and 3 were higher than for group 1. Bone area at 30 and 60 days for group 2 was higher than for groups 1 and 3. Titanium implants modified by laser with and without hydroxyapatite exhibit increased early osseointegration.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The objectives of this study were, through a literature review, to point the differences between orbital implants and their advantages and disadvantages, to evaluate prosthesis motility after orbital implants are inserted, and to point the implant wrapping current risks. Sixty-seven articles were reviewed. Enucleation implants can be autoplastics or alloplastics and porous (including natural and synthetic hydroxyapatite [HA]) or nonporous (silicone). Hydroxyapatite is the most related in the literature, but it has disadvantages, too, that is, all orbital implants must be wrapped. Exposure of the porous orbital implant can be repaired using different materials, which include homologous tissue, as well as autogenous graft, xenograft, and synthetic material mesh. The most used materials are HA and porous polyethylene orbital implant. The HA implant is expensive and possibly subject corals to damage, different from porous polyethylene orbital implants. Porous implants show the best prosthesis motility and a minimum rate of implants extrusion. Implant wraps can facilitate smoother entry of the implant into the orbit and allow reattachment of extraocular muscles. They also serve as a barrier between the overlying soft tissue and the rough surface of the implant, protecting implants from exposure or erosion.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Laminin-1 has been reported as one of the factors responsible for the nucleation of calcium phosphates and, in vitro, has been reported to selectively recruit osteoprogenitors. This article focused on its in vivo effects, and evaluated the effect of laminin-1 local application on osseointegration. Polished cylindrical hydroxyapatite implants were coated with laminin-1 (test) and the bone responses in the rabbit tibiae after 2 and 4 weeks were evaluated and compared to the non-coated implants (control). Before the samples were processed for histological sectioning, they were three-dimensionally analysed with micro computed tomography (μCT). Both evaluation methods were analysed with regards to bone area around the implant and bone to implant contact. From the histologic observation, new bone formation around the laminin-1 coated implant at 2 weeks seemed to have increased the amount of supporting bone around the implant, however, at 4 weeks, the two groups presented no notable differences. The two-dimensional and three-dimensional morphometric evaluation revealed that both histologic and three-dimensional analysis showed some tendency in favour of the test group implants, however there was no statistical significance between the test and control group results. © 2012 International Association of Oral and Maxillofacial Surgeons.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: Synthetic hydroxyapatite and porous polyethylene (Polipore) spheres were placed in rabbits' eviscerated cavities to evaluate tissue reaction and volume maintenance.Methods. Fifty-six Norfolk albino rabbits underwent unilateral evisceration and implantation of synthetic hydroxyapatite (H group, 28 animals) or porous polyethylene spheres (P group, 28 animals). Postoperative reactions, animal behavior, and socket conditions were monitored. Light microscopy and morphometric evaluation with statistical analysis of the exenterated orbits were performed at 7, 15, 30, 60, 90, 120, and 180 days. Scanning electron microscopy was appraised 7, 60, and 180 days after surgery.Results: Two animals from the H group and 1 from the P group had extrusion 7 days after surgery. Throughout the experimental period, the synthetic hydroxyapatite caused more inflammation than the porous polyethylene material. Ingrowth in the sphere occurred 7 to 15 days after the surgery in both groups, and the tissue reaction became denser at approximate to60 to 90 days, when bony metaplasia began in the H group. Volume maintenance was better in the P group and with a smaller pseudocapsule surrounding the implanted sphere than in the H group.Conclusions: Clinical findings demonstrated mild inflammation inside the sphere and in the pseudocapsule surrounding it and better cavity volume maintenance in the P group animals. The authors consider porous polyethylene a more suitable material than synthetic hydroxyapatite for use in anophthalmic cavity reconstruction.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Surface and biomechanical analysis of titanium implant surfaces modified by laser beam with and without hydroxyapatite. Titanium implants with 3 different surfaces were inserted into the tibias of 30 rabbits: group I (GI) machined surface (control group), group II irradiated with laser (GII), and group III irradiated with laser and hydroxyapatite coating applied-biomimetic method (GIII). Topographical analysis with scanning electron microscopy was made before surgery in the tibia. These rabbits were distributed into 2 periods of observation: 4 and 8 weeks postsurgery, after which biomechanical analysis (removal torque) was conducted. Statistical analysis used the Student-Newman-Keuls method. Surface showed roughness in GII and GIII. Biomechanical analysis demonstrated values with significant differences in GII and GIII. Titanium implants modified by laser irradiation can increase osseointegration during the initial phase.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Titanium surface texture and chemistry modification successfully improves the host response and consequently the bone-to-implant contact surrounding dental implants. The aim of the present study was to investigate, using histomorphometrical-analysis, the effects of titanium surface modification by laser-ablation (Nd:YAG) followed by thin chemical deposition of HA. Forty-eight rabbits received one implant by tibiae of AS-machined (MS), laser-modified (LMS), or biomimetic hydroxyapatite-coated (HA) surface. Bone-to-implant contact (BIC) and bone area (BBT) were evaluated after 4, 8, and 12 weeks, at cortical and cancellous regions. Average BIC in the cortical region was higher (P < 0.001) on the LMS and HA implants for all periods, with no differences between LMS and HA. For the cancellous area, the LMS and HA implants showed higher (P < 0.01) BIC than MS at the initial periods. The LMS and HA showed similar values in the cortical region, but a tendency of higher values for HA in the cancellous region was observed in all periods. For the BBT, the differences were found only between HA and MS after 4 weeks in the cortical region (P < 0.05), and after 12 weeks in the cancellous area (P < 0.05). Our results showed that HA biomimetic coating preceded by laser treatment induced the contact osteogenesis and allowed the formation of a more stable boneimplant interface, even in earlier periods. Microsc. Res. Tech., 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A regeneração periodontal e do rebordo ósseo utilizando barreiras físicas são procedimentos bem estabelecidos em cirurgias reconstrutivas. As características do biomaterial e o desenho da membrana empregados na regeneração tecidual guiada desempenham um papel importante na obtenção de bons resultados. O objetivo deste estudo experimental histológico foi comparar o uso de dois tipos de barreiras físicas na regeneração óssea guiada em defeitos criados na tíbia de ratos. Quinze animais foram divididos em três grupos: grupo I (barreira não-porosa de politetrafluoretileno), grupo II (blocos de hidroxiapatita de coral) e grupo III (controle que não recebeu nenhuma barreira). A análise histológica demonstrou várias quantidades de osso neoformado com ambos os tipos de barreiras. A barreira de politetrafluoretileno mostrou melhores resultados do que a hidroxiapatita. Os resultados deste estudo sugerem que a regeneração óssea pode ser conseguida com a técnica de submersão da barreira física.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Titanium alloys are hoped to be used much more for applications as implant materials in the medical and dental fields because of their basic properties, such as biocompatibility, corrosion resistance and specific strength compared with other metallic implant materials. Thus, the Ti-6Al-7Nb alloy that has recently been developed for biomedical use, that is, primarily developed for orthopaedic use, is to be studied in this paper, for application in dental implants. The biocompatibility test in vivo was carried out in dogs and the osseointegration was verified through histological analysis of the samples of the Ti-6Al-7Nb alloy with and without hydroxyapatite coating that were inserted in the alveoli. Within the controlled conditions the samples did not show any toxic effects on the cells. (C) 2001 Kluwer Academic Publishers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AimTo evaluate the influence of magnesium-enriched hydroxyapatite (MHA) (SintLife (R)) on bone contour preservation and osseointegration at implants placed immediately into extraction sockets.Material and methodsIn the mandibular pre-molar region, implants were installed immediately into extraction sockets of six Labrador dogs. MHA was placed at test sites, while the control sites did not receive augmentation materials. Implants were intended to heal in a submerged mode. After 4 months of healing, the animals were sacrificed, and ground sections were obtained for histomorphometric evaluation.ResultsAfter 4 months of healing, one control implant was not integrated leaving n=5 test and control implants for evaluation. Both at the test and the control sites, bone resorption occurred. While the most coronal bone-to-implant contact was similar between test and control sites, the alveolar bony crest outline was maintained to a higher degree at the buccal aspect of the test sites (loss: 0.7 mm) compared with the control sites (loss: 1.2 mm), even though this difference did not reach statistical significance.ConclusionsThe use of MHA to fill the defect around implants placed into the alveolus immediately after tooth extraction did not contribute significantly to the maintenance of the contours of the buccal alveolar bone crest.To cite this article:Caneva M, Botticelli D, Stellini E, Souza SLS, Salata LA, Lang NP. Magnesium-enriched hydroxyapatite at immediate implants: a histomorphometric study in dogs.Clin. Oral Impl. Res. 22, 2011; 512-517doi: 10.1111/j.1600-0501.2010.02040.x.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The commercial pure titanium (cp-Ti) is currently being used with great success in dental implants. In this work we investigate how the cp-Ti implants can be improved by modifying the metal surface morphology, on which a synthetic material with properties similar to that of the inorganic part of the bone, is deposited to facilitate the bone/implant bonding. This synthetic material is the hydroxyapatite, HA, a calcium-phosphate ceramic. The surface modification consists in the application of a titanium oxide (TiO2) layer, using the thermal aspersion - plasma spray technique, with posterior deposition of HA, using the biomimetic method. The X-ray diffraction (XRD), Scanning Electron Microscopy (SEM) with Energy Dispersive X-ray (EDX) and Diffuse Reflectance Infrared Fourier Transform (DRIFT) techniques have been used for characterizing phases, microstructures and morphologies of the coatings. The TiO2 deposit shows a mixture of anatase, rutilo and TiO2-x phases, and a porous and laminar morphology, which facilitate the HA deposition. After the thermal treatment, the previously amorphous structured HA coating, shows a porous homogeneous morphology with particle size of about 2-2.5 μm, with crystallinity and composition similar to that of the biological HA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Calcium phosphate-based bioactive ceramics in various physical and chemical formulations have been extensively utilized as biomaterials for bone regeneration/conduction. However, the determination of their in vivo temporal behavior from the short to long term in humans has been a challenge due to the lack of physical reference for morphologic and morphometric evaluation. The present study evaluated bone morphology and morphometry (bone-to-implant contact [BIC]) around plasma-sprayed hydroxyapatite (PSHA)-coated endosseous implants that were retrieved due to prosthetic reasons while successfully in function at the posterior region of the jaws from as early as 2 months to ~13 years after a 6-month healing period after placement. Bone morphology was evaluated by light microscopy, and BIC was determined using computer software. Irrespective of the time in vivo, lamellar bone was observed in close contact with the implant PSHA-coated surface and between plateaus. BIC ranged from ~35-95%, was highly directional, and Haversian-like osteonic morphology between plateaus was observed for most implants. The PSHA coating was present with little variation in thickness between the samples retrieved regardless of time in vivo. © 2010 by Begell House, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Major problems with the treatment of osteomyelitis are associated with poor antibiotic distribution at the site of infection due to limited blood circulation to the skeletal tissue. Improved treatment procedures have been used in drug delivery systems that include bioceramics and natural and synthetic polymers. This work reports the development of anionic collagen:hydroxyapatite composite paste for sustained antibiotic release. Antibiotic release by the composite was characterized by two steps. In the first, 15.0 +/- 4.9% was released in the first 5 h (n = 53) by a normal Fick diffusion mechanism. In the second step, only 16.8 +/- 2.2% was released after 7 days. In conclusion, hydroxyapatite:anionic collagen composite can be an efficient support for sustained antibiotic release in the treatment of osteomyelitis because most of the antibiotic release may be associated with composite bioresorption, thus permitting antibiotic release throughout the healing process. Hydroxyapatite:anionic collagen paste showed good biocompatibility associated with bone tissue growth with material still being observed after 60 days from the time of implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Considering the potential of the association between laser ablation and smaller scale hydroxyapatite (HA) coatings to create a stable and bioactive surface on titanium dental implants, the aim of the present study was to determine, by the removal torque test, the effects of a surface treatment created by laser-ablation (Nd:YAG) and, later, thin deposition of HA particles by a chemical process, compared to implants with only laser-ablation and implants with machined surfaces.Materials and Methods: Forty-eight rabbits received I implant by tibia of the following surfaces: machined surface (MS), laser-modified surface (LMS), and biomimetic hydroxiapatite coated surface (HA). After 4, 8, and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition, and roughness.Results: Average removal torque in each period was 23.28, 24.0, and 33.85 Ncm to MS, 33.0, 39.87, and 54.57 Ncm to LMS, and 55.42, 63.71 and 64.0 Ncm to HA. The difference was statistically significant (P < .05) between the LMS-MS and HA-MS surfaces in all periods of evaluation, and between LMS-HA to 4 and 8 weeks of healing. The surface characterization showed a deep, rough, and regular topography provided by the laser conditioning, that was followed by the HA coating.Conclusions: Based on these results, it was possible to conclude that the implants with laser surface modification associated with HA biomimetic coating can shorten the implant healing period by the increase of bone implant interaction during the first 2 months after implant placement. (C) 2009 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 67:1706-1715, 2009

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background:Bone graft procedures have been used commonly in buco-maxillo-facial surgery. For this reason, many researchers have evaluated the bone substitutes.Purpose:The present study evaluated soft and hard tissue reactions to two different hydroxyapatites HAs (synthetic HA and natural HA) and bioactive glass implanted into the sockets immediately after extraction.Materials and Methods:First and third upper and lower premolars, on both sides, were extracted from six female dogs. The alveolar sockets were randomly assigned to four groups: Group 1 - control (unfilled), Group 2 - filled with synthetic hydroxyapatite, Group 3 - filled with bovine bone mineral (natural HA), and Group 4 - filled with bioactive glass. The animals were euthanized at 4 weeks (n = 2), 8 weeks (n = 2), and 28 weeks (n = 2) after extraction. The mandible and maxilla of each animal were removed for histological analysis to determine soft tissue reactions, newly formed bone, bone characteristics, and presence or absence of implanted materials.Results:Most particles of synthetic hydroxyapatite had bone formation on their surface, although some particles showed a layer of fibrous connective tissue. The bovine bone mineral group exhibited particles partially replaced with bone formation. The bioactive glass group showed particles with a thin layer of calcified tissue, but was absent in some specimens, suggesting complete resorption.Conclusion:All biomaterials had similar behavior. Bovine bone mineral, compared to synthetic hydroxyapatite and bioactive glass, showed a larger number of particles covered with osseous tissue. All biomaterials interfered with the socket repair process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: the aim of this study was to assess, through Raman spectroscopy, the incorporation of calcium hydroxyapatite (CHA; similar to 960 cm(-1)), and scanning electron microscopy (SEM), the bone quality on the healing bone around dental implants after laser photobiomodulation ( lambda 830 nm). Background Data: Laser photobiomodulation has been successfully used to improve bone quality around dental implants, allowing early wearing of prostheses. Methods: Fourteen rabbits received a titanium implant on the tibia; eight of them were irradiated with lambda 830 nm laser ( seven sessions at 48-h intervals, 21.5 J/cm(2) per point, 10 mW, phi similar to 0.0028 cm(2), 86 J per session), and six acted as control. The animals were sacrificed 15, 30, and 45 days after surgery. Specimens were routinely prepared for Raman spectroscopy and SEM. Eight readings were taken on the bone around the implant. Results: the results showed significant differences on the concentration of CHA on irradiated and control specimens at both 30 and 45 days after surgery ( p < 0.001). Conclusion: It is concluded that infrared laser photobiomodulation does improve bone healing, and this may be safely assessed by Raman spectroscopy or SEM.