59 resultados para door handles


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of ergonomics in product design is essential to its accessibility and usability. The development of manual devices should be based on ergonomic principles. Effort perception analysis is an essential approach to understand the physical and subjective aspects of the interface. The objective of the present study was to analyze the effort perception during a simulated task with different door handles by Portuguese subjects of both genders and different ages. This transversal study agreed with ethical aspects. 180 subjects of both genders pertaining to three age groups have participated. Five door handles with different shapes were evaluated. A subjective numeric rating scale of 5 levels was used to evaluate the effort. For statistical analysis it was applied the Friedman non-parametric test. The results have showed no significant differences of effort perception in door handles "A" and "B"; "A" and "D"; and "D" and "C". Door handle "E" presented the lowest values of all. In general, there's an inverse relationship between the results of biomechanical studies and the effort perception of the same task activity. This shows that door handles design influence directly these two variables and can interfere in the accessibility and usability of these kinds of products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to achieve better postures and decrease musculoskeletal risks adequate design of hand/box couplings for manual materials handling (MMH) are still needed. No studies evaluating upper limb movement thorough direct measurements during box handling in workplace were identified in the literature. In this study we describe the types of grip and movements adopted by ten workers when handling redesigned boxes with cutout handles between different heights on industrial pallets. The new handles were used by 90% of the workers through different types of grip. Electrogoniometric measurements showed relatively safe forearm and wrist movements, although elbow inadequate range of movement was recorded. Despite the good acceptance of the cutout by workers, the new design requires extra internal space in the boxes reducing applications for this alternative of box.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTUALIZAÇÃO:O manuseio de materiais está ainda presente nos setores industriais e é associado a lesões na coluna lombar e membros superiores. A inserção de alças em caixas industriais é uma forma de reduzir os riscos relacionados à tarefa, porém a posição e a angulação das alças, que são fatores importantes para o conforto e segurança durante o manuseio, são ainda pouco investigadas objetivamente.OBJETIVOS:Comparar o manuseio de uma caixa comercial e de protótipos com alças e avaliar seus efeitos na postura de membros superiores, atividade elétrica muscular e percepção de agradabilidade em diferentes empunhaduras durante manuseio entre diferentes alturas.MÉTODO:Trinta e sete voluntários saudáveis avaliaram as alças dos protótipos que possibilitavam mudança nas posições (superior e inferior) e angulações (0°, 15° e 30º). Os movimentos dos punhos, cotovelos e ombros foram avaliados por meio da eletrogoniometria e inclinometria. A atividade elétrica muscular dos extensores do punho, bíceps braquial e porção superior do trapézio foi avaliada por um eletromiógrafo portátil. Os registros de movimento e atividade elétrica muscular foram sincronizados. Aspectos subjetivos de agradabilidade foram avaliados por meio de uma escala visual analógica.RESULTADOS E CONCLUSÕES:Os protótipos com alças inclinadas em 30° apresentaram as melhores avaliações de agradabilidade, posturas mais neutras de punho, menores níveis de atividade eletromiográfica do trapézio superior e menores ângulos de elevação dos braços. Os diferentes métodos de medida se mostraram complementares para a avaliação dos membros superiores durante as tarefas de manuseio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents an assessment with simulated activities with the aim of analyzing the perception of ease/difficulty of the use of faucets (taps) handles by 180 Brazilian adults. Five different handles faucets were activated for subsequent collection of perceptual data. The procedures were based on main recommendations for biomedical ethics and human research. The results indicate that handles with levers are significantly (p <= 0.05) easier to use. The most difficult are characterized by not having support points for the rotation (levers) or more points of pressure concentration in the hand.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Para avaliar procedimentos para a manutenção da umidade do substrato durante o teste de germinação de Brachiaria brizantha. Estudou-se o efeito da posição das caixas plásticas na câmara de germinação sobre a perda de água semanal, testando-se nove posições verticais (bandejas) e três posições horizontais (porta, meio e fundo do germinador). Foi também avaliado o efeito de procedimentos para manter a umidade do substrato, sobre a germinação, a perda de água semanal e o tempo despendido para a instalação do teste. Os procedimentos testados foram: (a) vedação da caixa plástica com vaselina, (b) vedação com saco plástico dobrado em quatro e colocado entre a tampa e a caixa, (c) colocação da caixa tampada dentro de saco plástico, (d) espuma sob o papel de germinação e (e) testemunha, caixa apenas tampada. Concluiu-se que a câmara de germinação promove a desidratação desigual do substrato conforme a posição das caixas; aquelas localizadas na primeira bandeja superior são as mais prejudicadas. Entre os procedimentos, a vedação com vaselina, a colocação da caixa dentro de saco plástico e a vedação com saco plástico dobrado em quatro entre a tampa e a caixa são eficientes na manutenção da umidade do substrato em taxas que não alteram os resultados do teste de germinação de B. brizantha; os dois últimos procedimentos são os mais rápidos e práticos, adaptando-se à rotina de um laboratório de análise de sementes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents an efficient approach based on a recurrent neural network for solving constrained nonlinear optimization. More specifically, a modified Hopfield network is developed, and its internal parameters are computed using the valid-subspace technique. These parameters guarantee the convergence of the network to the equilibrium points that represent an optimal feasible solution. The main advantage of the developed network is that it handles optimization and constraint terms in different stages with no interference from each other. Moreover, the proposed approach does not require specification for penalty and weighting parameters for its initialization. A study of the modified Hopfield model is also developed to analyse its stability and convergence. Simulation results are provided to demonstrate the performance of the proposed neural network.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a hybrid way mixing time and frequency domain for transmission lines modelling. The proposed methodology handles steady fundamental signal mixed with fast and slow transients, including impulsive and oscillatory behaviour. A transmission line model is developed based on lumped elements representation and state-space techniques. The proposed methodology represents an easy and practical procedure to model a three-phase transmission line directly in time domain, without the explicit use of inverse transforms. The proposed methodology takes into account the frequency-dependent parameters of the line, considering the soil and skin effects. In order to include this effect in the state matrices, a fitting method is applied. Furthermore the accuracy of proposed the developed model is verified, in frequency domain, by a simple methodology based on line distributed parameters and transfer function related to the input/output signals of the lumped parameters representation. In addition, this article proposes the use of a fast and robust analytic integration procedure to solve the state equations, enabling transient and steady-state simulations. The results are compared with those obtained by the commercial software Microtran (EMTP), taking into account a three-phase transmission line, typical in the Brazilian transmission system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose an alternative formalism to simulate cosmic microwave background (CMB) temperature maps in Lambda CDM universes with nontrivial spatial topologies. This formalism avoids the need to explicitly compute the eigenmodes of the Laplacian operator in the spatial sections. Instead, the covariance matrix of the coefficients of the spherical harmonic decomposition of the temperature anisotropies is expressed in terms of the elements of the covering group of the space. We obtain a decomposition of the correlation matrix that isolates the topological contribution to the CMB temperature anisotropies out of the simply connected contribution. A further decomposition of the topological signature of the correlation matrix for an arbitrary topology allows us to compute it in terms of correlation matrices corresponding to simpler topologies, for which closed quadrature formulas might be derived. We also use this decomposition to show that CMB temperature maps of (not too large) multiply connected universes must show patterns of alignment, and propose a method to look for these patterns, thus opening the door to the development of new methods for detecting the topology of our Universe even when the injectivity radius of space is slightly larger than the radius of the last scattering surface. We illustrate all these features with the simplest examples, those of flat homogeneous manifolds, i.e., tori, with special attention given to the cylinder, i.e., T-1 topology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An automatic Procedure with a high current-density anodic electrodissolution unit (HDAE) is proposed for the determination of aluminium, copper and zinc in non-ferroalloys by flame atonic absorption spectrometry, based on the direct solid analysis. It consists of solenoid valve-based commutation in a flow-injection system for on-line sample electro-dissolution and calibration with one multi-element standard, an electrolytic cell equipped with two electrodes (a silver needle acts as cathode, and sample as anode), and an intelligent unit. The latter is assembled in a PC-compatible microcomputer for instrument control, and far data acquisition and processing. General management of the process is achieved by use of software written in Pascal. Electrolyte compositions, flow rates, commutation times, applied current and electrolysis time mere investigated. A 0.5 mol l(-1) HNO3 solution was elected as electrolyte and 300 A/cm(2) as the continuous current pulse. The performance of the proposed system was evaluated by analysing aluminium in Al-allay samples, and copper/zinc in brass and bronze samples, respectively. The system handles about 50 samples per hour. Results are precise (R.S.D < 2%) and in agreement with those obtained by ICP-AES and spectrophotometry at a 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection system with online sample preparation is proposed for the determination of phosphite in liquid fertilizers by spectrophotometry. After loop-based injection, phosphite is oxidized by an acidic permanganate solution (1.0 10(-2) mol L-1 KMnO4 + 1.0 mol L-1 H2SO4) in a heated reactor (50 degreesC). The phosphate generated is then determined by the molybdenum blue method. Influence of flow rates, temperature, and concentration and order of addition of reagents, sample volume, and reactor configuration for the blue complex formation on recorded signals were investigated. The pow system was applied to phosphite determination in commercial samples of liquid fertilizers. The proposed system handles about 80 samples per hour [0.05-0.40% (w/v) H3PO3; R = 0,9998], consuming about 80 muL sample, 1 mg KMnO4, 25 mg (NH)(6)Mo7O24, and Ia mg ascorbic acid per determination. Results are precise [relative standard deviation less than or equal to 3.5% for 0.1% (w/v) H3PO3, n = 12] and in agreement with those obtained by gravimetry at 95% confidence level. (C) 2000 John Wiley & Sons, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A reversible intermittent pow-injection procedure is proposed for the automated determination of mercury in sediments and vinasses by cold vapor atomic absorption spectrometry, CVAAS. Solutions of sample and stannous chloride are carried by two air streams and sequentially injected into the generator/separator chamber in a segmented asynchronous merging zone configuration. The intermittent flow in the forward direction carries the mercury vapor through the flow cell, and in the backward direction, if aspirates the the remaining solution from the vessel to waste. We investigated composition and concentration of reagents, pow rates, commutation times, reactor configuration, and conditions for mercury release. The accuracy was checked by mercury determination in a certified sediment and spiked vinasses and river waters. The system handles about 100 samples per hour (0.50-5.00 mu g L-1), consuming ca. 2.5 mL of sample and 50 mg of SnCl2 per determination; Good recoveries (92-103%) were obtained with spiked samples. Results are precise (RSD <3% for 2.5 mu g Hg L-1, n = 12) and in agreement with values for certified reference material at 95% confidence level. (C) 1999 John Wiley & Sons, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensor based on graphite electrode modified with palladium-platinum-palladium film is proposed for phosphite determination by flow-injection amperometry. The modified electrode was prepared by a sequential cathodic deposition of Pd, Pt and Pd on a graphite electrode from 0.5% m/v PdCl2 + 28% m/v NH4OH and 2% m/v H2PtCl6 + 10% v/v H2SO4 solutions. After suitable conditioning, the electrode showed catalytic activity for phosphite oxidation when 0. 15 V was applied. The proposed system handles approximately 50 samples per hour (0.0.1 - 0.05 mol L-1 Na-2 HPO3; R-2 = 0.9997), consuming ca. 70 mu L of sample per determination. The limit of detection and amperometric sensibility were 5 X 10(-4) mol L-1 and 1.5 mA L mol(-1), respectively. The proposed method was applied to analysis of fertilizer samples without pre-treatment. Results are in agreement with those obtained by spectrophotometry and titrimetry at 95% confidence level and good recoveries (96-109%) of spiked samples were found. Relative standard deviation (n=12) of a 0.01 mol L-1 Na2HPO3 sample was 2%. The useful lifetime of modified electrode was around 220 determinations. For routine purposes it means that this electrode can be continuously used for 5 hours.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a technique for extending the force range of thin conductive polymer force sensors used for measuring contact force. These sensors are conventionally used for measuring force by changing electrical resistance when they are compressed. The new method involves measuring change in electrical resistance when the flexible sensor, which is sensitive to both compression and bending, is sandwiched between two layers of spring steel, and the structure is supported on a thin metal ring. When external force is applied, the stiffened sensor inside the spring steel is deformed within the annular center of the ring, causing the sensor to bend in proportion to the applied force. This method effectively increases the usable force range, while adding little in the way of thickness and weight. Average error for loads between 10 N and 100 N was 2.2 N (SD = 1.7) for a conventional conductive polymer sensor, and 0.9 N (SD = 0.4) using the new approach. Although this method permits measurement of greater loads with an error less than 1 N, it is limited since the modified sensor is insensitive to loads less than 5 N. These modified sensors are nevertheless useful for directly measuring normal force applied against handles and tools and other situations involving forceful manual work activities, such as grasp, push, pull, or press that could not otherwise be measured in actual work situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tin on the oxide form, alone or doped with others metals, has been extensively used as gas sensor, thus, this work reports on the preparation and kinetic parameters regarding the thermal decomposition of Sn(II)-ethylenediaminetetraacetate as precursor to SnO2. Thus, the acquaintance with the kinetic model regarding the thermal decomposition of the tin complex may leave the door open to foresee, whether it is possible to get thin film of SnO2 using Sn(II)-EDTA as precursor besides the influence of dopants added.The Sn(II)-EDTA soluble complex was prepared in aqueous medium by adding of tin(II) chloride acid solution to equimolar amount of ammonium salt from EDTA under N-2 atmosphere and temperature of 50degreesC arising the pH similar to 4. The compound was crystallized in ethanol at low-temperature and filtered to eliminate the chloride ions, obtaining the heptacoordinated chelate with the composition H2SnH2O(CH2N(CH2COO)(2))(2).0.5H(2)O.Results from TG, DTG and DSC curves under inert and oxidizing atmospheres indicate the presence of water coordinated to the metal and that the ethylenediamine fraction is thermally more stable than carboxylate groups. The final residue from thermal decomposition was the SnO2 characterized by X-ray as a tetragonal rutile phase.Applying the isoconversional Wall-Flynn-Ozawa method on the DSC curves, average activation energy: E-a = 183.7 +/- 12.7 and 218.9 +/- 2.1 kJ mol(-1), and pre-exponential factor: log A = 18.85 +/- 0.27 and 19.10 +/- 0.27 min(-1), at 95% confidence level, could be obtained, regarding the loss of coordinated water and thermal decomposition of the carboxylate groups, respectively. The E-a and logA also could be obtained applying isoconventional Wall-Flynn method on the TG curves.From E-a and log A values, Dollimore and Malek procedures could be applied suggesting R3 (contracting volume) and SB (two-parameter model) as the kinetic model to the loss of coordinated water (177-244degreesC) and thermal decomposition of the carboxylate groups (283-315degreesC), respectively. Simulated and experimental normalized DTG and DSC curves besides analysis of residuals check these kinetic models. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow-injection system with a Chelite-S® cationic resin packed minicolumn is proposed for the determination of trace levels of mercury in agroindustrial samples by cold vapor atomic absorption spectrometry. Improved sensitivity and selectivity are attained since mercuric ions are on-line concentrated whereas other potential interferents are discarded. With on-line reductive elution procedure, concentrated hydrochloric acid could be replaced by 10% w/v SnCl2, in 6 M HCl as eluent. The reversed-intermittent stream either carries the atomic mercury, to the flow cell in the forward direction or removes the residue from reactor/gas liquid separator to a discarding flask in the opposite direction. Concentration and volume of reagent, acidity, flow rates, commutation times and potential interfering species were investigated. For 120 s preconcentration time, the proposed system handles about 25 samples h-1 (50.0 500 ng l-1), consuming about 10 ml sample and 5 mg SnCl2 per determination. The detection limit is 0.8 ng l-1 and the relative standard deviation (RSD) (n = 12) of a 76.7 ng l-1 sample is about 5%. Results are in agreement with certified value of standard materials at 95% confidence level and good recoveries (97-128%) of spiked samples were found. (C) 2000 Elsevier Science B.V.