119 resultados para advanced HSLA and conventional HSLA steels


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this work is to explain the concept of cutting fluids reasonable usage through the fluid minimum quantity in grinding processes. on that purpose, the development of a new nozzle and an own and adequate methodology should be required in order to obtain good results and compare them to the conventional methods. The analysis of the grinding wheel/cutting fluid performance was accomplished from the following input parameters: flow rate variation by nozzle diameter changes (three diameters values: 3mm, 4mm and 5mm), besides the conventional round nozzle already within the machine. Integral oil and a synthetic emulsion were used as cutting fluids and a conventional grinding wheel was employed. The workpieces were made of steel VC 131, tempered and quenched with 60HRc. Thus, as the flow rate and the nozzle diameter changes, keeping steady fluid jet velocity (equal to cutting velocity), attempted to find the best machining conditions, with the purpose to obtain a decrease on the cutting fluid volume, taking into consideration the analysis of the process output variables such as cutting strength, cutting specific energy, grinding wheel wear and surface roughness. It was verified that the 3mm diameter optimized nozzle and the integral oil, in general, was the best combination among all proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The law's project n.676/2000 approved the collecting of billing water for farmers in a maximum foreseen value of US$ 0.01 m(-3) of extracted water in the São Paulo State. As the irrigated agriculture is the activity that consumes more water, the farmers profitability can be affected. This work was to analyze the economic impact of billing water in the aspersion irrigated bean crop to consider the system of conventional production and no tillage system in the Paranapanema municipal district, São Paulo State, Brazil. The indicators used to analyze the economic results were unit variable cost, market price and unit profitability. The results showed that for the aspersion irrigated bean crop in conventional system, the participation of cost to the recourse water in cost variable totality was of 2.5% and in no tillage system the participation was of 2.2%. The fall of profitability just the billing water in conventional crop system and in no tillage system was US$ 0.01 kg(-1).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the micromorphology of CVD diamond tips coupled to ultrasound with conventional high speed diamond tips after cavity preparations, and to measure the width and depth of the cavities obtained. Two hundred bovine teeth were divided into 20 subgroups. Each of the diamond tips (10 CVD and 10 conventional) were used to prepare 10 standardized cavities, using an apparatus that controlled the time (t: 27 s), speed (5.3 mm/s) and load (0.012 KGF) of the tip against the teeth during preparation. The unused and the used (after one, five and 10 preparations) tips were analyzed by scanning electronic microscopy. The images were randomly assessed by 3 examiners with regard to the presence or absence of micromorphologic alterations. Cavity measurements were made after visualization under a stereoscopic microscope. Cavity widths and depths were analyzed by the ANOVA Factorial test (p < 0.05). The CVD diamond tips presented less wear than the conventional tips after all the cavity preparations performed, but produced shallower cavities that were equivalent in width to those made by conventional tips after the fifth preparation. CVD diamond tips may be suggested as an alternative to conventional diamond tips due to their conservative preparation and greater longevity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of problem. An increase in occlusal vertical dimension (OVD) may occur after processing complete dentures. Although many factors that generate this change are known, no information is available in the dental literature regarding the effect that the occlusal scheme may have on the change in OVD.Purpose. This in vitro study compared the increase in OVD, after processing, between complete dentures with teeth arranged in lingualized balanced occlusion and conventional balanced occlusion.Material and methods. Thirty sets of complete dentures were evaluated as follows: 15 sets of complete dentures were arranged in conventional balanced occlusion (control) and 15 sets of complete dentures were arranged in lingualized balanced occlusion. All dentures were compression molded with a long polymerization cycle. The occlusal vertical dimension was measured with a micrometer (mm) before and after processing each set of dentures. Data were analyzed using an independent t test (alpha=.05).Results. The mean increase in the OVD, after processing, was 0.87 +/- 0.21 mm for the control group and 0.90 +/- 0.27 mm for the experimental group. There was no significant difference between the groups.Conclusion. After processing, dentures set in lingualized balanced occlusion showed an increase in OVD similar to those set in conventional balanced occlusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este estudo avaliou, in vitro, a atividade antibacteriana de soluções irrigadoras convencionais e experimentais sobre Enterecoccus faecalis. As seguintes substâncias foram avaliadas por teste de contato direto: hipoclorito de sódio (NaOCl) a 2,5%, clorexidina (CHX) a 2%, ácido peracético a 1%. Após diferentes períodos de contato (30 s, 1, 3 e 10 min), um agente neutralizante foi empregado. Diluições decimais seriadas foram realizadas e semeadas em placas de tryptic soy agar (TSA). O número de unidades formadoras de colônia por mililitro (UFC/mL) foi determinado. Solução salina foi utilizada como controle negativo. Ambos, NaOCl a 2,5% e CHX a 2%, eliminaram E. faecalis após 30 s de contato. O ácido peracético reduziu a contagem bacteriana em 86% após 3 min e eliminou completamente E. faecalis após 10 min. Estes resultados permitem concluir que o ácido peracético a 1% é efetivo sobre E. faecalis, apesar de sua ação mais lenta quando comparado ao NaOCl a 2,5% e CHX a 2%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>The present review reports on the main characteristics and properties of plants cultivated following organic and conventional procedures, in the attempt to clarify give a deeper insight into some possible differences and to compare the two cultivation procedures. Here, we summarise research results regarding nutritional and safety properties of vegetable foods, evidencing qualitative differences observed between the two cultivation methods. It appears that the intake of organic foods leads to some advantages, such as the ingestion of a higher content of phenolic compounds and some vitamins, such as vitamin C, and a lower content of nitrates and pesticides. From literature, it appears that a special care should be taken about the ingestion of foods in relation to the content of some substances, e.g. polyamines, substances stimulating cellular division, because some foods coming from organic origin present a higher content of these compounds, which could explain some of the effect of the diet on patients affected by certain syndromes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A performance comparison between a recently proposed novel technique known as fast orthogonal frequency-division multiplexing (FOFDM) and conventional orthogonal frequency-division multiplexing (OFDM) is undertaken over unamplified, intensity-modulated, and direct-detected directly modulated laser-based optical signals. Key transceiver parameters, such as the maximum achievable transmission capacity and the digital-to-analog/analog-to-digital converter (DAC/ADC) effects are explored thoroughly. It is shown that, similarly to conventional OFDM, the least complex and bandwidth efficient FOFDM can support up to similar to 20 Gb/s over 500 m worst-case multimode fiber (MMF) links having 3 dB effective bandwidths of similar to 200 MHz X km. For compensation of the DAC/ADC roll-off, a power-loading (PL) algorithm is adopted, leading to an FOFDM system improvement of similar to 4 dB. FOFDM and conventional OFDM give similar optimum DAC/ADC parameters over 500 m worst-case MMF, while over 50 km single-mode fiber a maximum deviation of only similar to 1 dB in clipping ratio is observed due to the imperfect chromatic dispersion compensation caused by one-tap equalizers.