50 resultados para Thermal performance
Resumo:
A thorough study of the thermal performance of multipass parallel cross-flow and counter-cross-flow heat exchangers has been carried out by applying a new numerical procedure. According to this procedure, the heat exchanger is discretized into small elements following the tube-side fluid circuits. Each element is itself a one-pass mixed-unmixed cross-flow heat exchanger. Simulated results have been validated through comparisons to results from analytical solutions for one- to four-pass, parallel cross-flow and counter-cross-flow arrangements. Very accurate results have been obtained over wide ranges of NTU (number of transfer units) and C* (heat capacity rate ratio) values. New effectiveness data for the aforementioned configurations and a higher number of tube passes is presented along with data for a complex flow configuration proposed elsewhere. The proposed procedure constitutes a useful research tool both for theoretical and experimental studies of cross-flow heat exchangers thermal performance.
Resumo:
A new numerical methodology for thermal performance calculation in cross-flow heat exchangers is developed. Effectiveness-number of transfer units (epsilon-NTU) data for several standard and complex flow arrangements are obtained using this methodology. The results are validated through comparison with analytical solutions for one-pass cross-flow heat exchangers with one to four rows and with approximate series solution for an unmixed-unmixed heat exchanger, obtaining in all cases very small errors. New effectiveness data for some complex configurations are provided. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The work aimed at presenting analyses and comparisons of the thermal performance of a laying hens housing in the region of Bastos, in the state of São Paulo, adapted from natural alternatives of acclimatization, having a not adapted housing as reference, that is, of a more common typology in the area, and another one, artificially acclimatized. The index evaluated was the temperature and humidity (THI), the black globe temperature and humidity index (GTHI) and the thermal radiation charge (TRC). It was calculated from the measurement of the temperature of dry bulb, temperature of wet bulb, temperature of black globe and air speed. The measurements were made both in the intern and the extern environment, at four times (5 a.m, 11 a.m., 3 p.m. and 4 p.m. o'clock) and in two seasons (late spring and early summer), for ten days in a row. The results allow to conclude that the house naturally acclimatized (NA) has presented intermediate performance as compared with the others, making it to possible to control environment at adequate levels only during spring.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study aimed at evaluating the thermal performance of a modular ceiling system for poultry houses. The reduced- and distorted-scale prototypes used ceiling modules made of reforested wood and were covered with recycled long-life package tiles. The following parameters were measured for 21 days: tile internal surface temperature (ST), globe temperature and humidity index (WBGT), and radiant heat load (RHL). Measurements were made at times of highest heat load (11:00 am, 13:00 pm, and 03:00 pm). Collected data were analyzed by R statistics software. Means were compared by multiple comparison test (Tukey) and linear regression was performed, both at 5% significance level. The results showed that the prototype with the ceiling was more efficient to reduce internal tile surface temperature; however, this was not sufficient to provide a comfortable environment for broilers during the growout. Therefore, other techniques to provide proper cooling are required in addition to the ceiling.
Resumo:
A green ceramic tape micro heat exchanger was developed using LTCC technology. The device was designed by using a CAD software and 2D and 3D simulations using a CFD package (COMSOL Multiphysics) to evaluate the fluid behavior in the microchannels. The micro heat exchanger is composed of five thermal exchange plates in cross flow arrangement and two connecting plates; heat exchanger dimensions are 26 × 26 × 6 mm3. Preliminary tests were carried out to characterize the device both in atmospheric pressure and in vacuum. The same techniques used in vacuum technology were applied to check the rotameters and to prevent device leakages. Thermal performance of the micro heat exchanger was experimentally tested. © 2009 Elsevier B.V. All rights reserved.
Resumo:
In order to investigate how environmental degradation affects the mechanical and thermal performance of polyetherimide/carbon fiber laminates, in this work different weathering were conducted. Additionally, dynamic mechanical analysis, interlaminar shear strength tests and non-destructive inspections were performed on this composite before and after being submitted to hygrothermal, UV radiation and thermal shock weathering. According to our results, hygrothermally aged samples had their glass transition temperature and elastic and storage moduli reduced by plasticization effect. Photooxidation, due to UV radiation exposure, occurred only on the surface of the laminates. Thermal shock induced a reversible stress on the composite's interface region. The results revealed that the mechanical behavior can vary during weather exposure but since this variation is only subtle, this thermoplastic laminate can be considered for high-performance applications, such as aerospace. © The Author(s) 2013.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Dissipadores de calor recobertos com filmes de diamante CVD foram desenvolvidos para acoplar a semicondutores, utilizando-se do Laboratório de Deposição de Filmes de Diamante CVD, na UNESP - Campus de Guaratinguetá e o Laboratório de Diamantes da Universidade São Francisco, em Itatiba, SP. Analisou-se o filme de diamante CVD sobre o silício, para emprego como dissipador de calor, porque o filme de diamante CVD pode ter o valor da condutividade térmica até cinco vezes superior ao do cobre e de dez vezes a do alumínio. Os filmes foram obtidos via deposição através de reator de filamento quente, trabalhando-se com vários filamentos retilíneos em paralelo, resultando assim em um processo que visou obter um filme mais uniforme e com grande área de deposição. Os dados para análises da composição química superficial dos filmes foram obtidos por Difração de Raios-X, Dispersão de Energia de Raios-X e para a verificação da morfologia e espessura do filme foi utilizada a Microscopia Eletrônica de Varredura. Para a verificação do comportamento da temperatura sobre o dissipador com o filme de diamante CVD foi utilizada uma câmera de imagem termográfica, marca Fluke, modelo Ti 40 FT. Foram obtidos filmes de 2 e 10 ?m sobre o silício. Estas espessuras ainda não oferecem um desempenho mecânico que o torne autosustentado. Do ponto de vista de desempenho térmico as análises mostraram que, mesmo com pequena espessura, o filme de diamante CVD apresentou bom resultado experimental. Os principais desafios de construção para esse dissipador de calor são a obtenção do filme com espessura acima de um mm e a garantia da qualidade do filme com a repetitividade do processo em cujo caso torna-se necessário definir as dimensões do dissipador antes da deposição do filme.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS