16 resultados para Synthetic materials


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Natural or synthetic materials may be used to aid tissue repair of fracture or pathologies where there has been a loss of bone mass. Polymeric materials have been widely studied, aiming at their use in orthopaedics and aesthetic plastic surgery. Polymeric biodegradable blends formed from two or more kinds of polymers could present faster degradation rate than homopolymers. The purpose of this work was to compare the biological response of two biomaterials: poly(L-lactic acid)PLLA and poly(L-lactic acid)PLLA/poly(ethylene oxide)PEO blend. Forty four-week-old rats were divided into two groups of 20 animals, of which one group received PLLA and the other PLLA/PEO implants. In each of the animals, one of the biomaterials was implanted in the proximal epiphysis of the right tibia. Each group was divided into subgroups of 5 animals, and sacrificed 2, 4, 8 and 16 weeks after surgery, respectively. Samples were then processed for analysis by light microscopy. Newly formed bone was found around both PLLA and PLLA/PEO implants. PLLA/PEO blends had a porous morphology after immersion in a buffer solution and in vivo implantation. The proportion 50/50 PLLA/PEO blend was adequate to promote this porous morphology, which resulted in gradual bone tissue growth into the implant.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of bowel segments to perform bladder augmentation is associated with several metabolic and surgical complications. A great variety of synthetic materials, biodegradable or not, have been tested. Collagen-based biomaterials have shown effectiveness for the regeneration and obtainment of a functional bladder. Assess the functional and histological response of the rabbit bladder to anionic collagen membrane (ACM), either when it is anastomosed to the bladder or it is placed onto bladder after vesicomyectomy. In 15 male rabbit a partial cystectomy was performed. After 4 weeks they were divided in 3 groups. Group 1 (G1) - bladder augmentation with ACM. Group 2 (G2) ACM is placed onto bladder after vesicomyectomy. Group 3 (G3) control group. Maximal bladder capacity (MBC) and weight were assessed with 4 (M1), 8 (M2) and 12 (M3) weeks after partial cystectomy. In M3 was performed the sacrifice and extraction of the bladder and kidneys for anatomopathologic study. There were neither bladder stones, nor implant extrusion in M3. There was a significant increase in MBC in G1 and G2 (p<0.05), but no statistical differences in G3 (p=0.35). There is no significant difference comparing G1 and G2. In M3, both groups have shown a bigger MBC than G3 (p<0.05). The microscopic assessment showed an inflammatory reaction in the bladder augmented, with urothelium preserved. The ACM was effective for the increase of MBC. The bladders with preservation of the urothelium have shown an extensive inflammatory process.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To assess the acquisition of suture skills by training on ethylene-vinyl acetate bench model in novice medical students.METHODS: Sixteen medical students without previous surgery experience (novices) were randomly divided into two groups. During one hour group A trained sutures on ethylene-vinyl acetate (EVA) bench model with feedback of instructors, while group B (control) received a faculty-directed training based on books and instructional videos. All students underwent a both pre-and post-tests to perform two-and three-dimensional sutures on ox tongue. All recorded performances were evaluated by two blinded evaluators, using the Global Rating Scale.RESULTS: Although both groups have had a better performance (p<0.05) in the post-test when compared with the pre-test, the analysis of post-test showed that group A (EVA) had a better performance (p<0.05) when compared with group B (control).CONCLUSION: The ethylene vinyl acetate bench model allowed the novice students to acquire suture skills faster when compared to the traditional model of teaching.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The release of fluoride from restorative materials (Vitremer, Ketac-Fil, Fuji II LC and Freedom) was evaluated during two 15-day periods, before and after a topical application of acidulated phosphate fluoride gel (APF). For each material, 6 specimens were made, which were immersed in 2 ml of deionized water. The fluoride concentration dosages in the solutions were read at intervals of 24 hours for 15 days. After this period, the specimens of each material received treatment with APF gel for 4 minutes and the fluoride released was analyzed at 24-hour intervals during the following 15 days. The analysis of variance and the Tukey test (p < 0.05) showed that the total mean fluoride released during the initial 15 days was greater for Vitremer and Ketac-Fil and lower for Fuji II LC and Freedom; and in the final 15 days there was a difference in release readings, with the greatest value for Vitremer, followed by Fuji II LC, Ketac-Fil and Freedom. The comparison of the results between the 1st day and the 16th day (after gel application) showed a greater fluoride release on the 16th day for Vitremer, Fuji II LC and Freedom and was equal for Ketac-Fil. Although all the materials evaluated gained fluoride with the application of APF, the data suggest that the resin-modified ionomers are more efficient in releasing fluoride to the medium than the other materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the surface microhardness and fluoride release of 5 restorative materials - Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil - in two storage media: distilled/deionized water and a pH-cycling (pH 4.6). Twelve specimens of each material, were fabricated and the initial surface microhardness (ISM) was determined in a Shimadzu HMV-2000 microhardness tester (static load Knoop). The specimens were submitted to 6- or 18-h cycles in the tested media. The solutions were refreshed at the end of each cycle. All solutions were stored for further analysis. After 15-day storage, the final surface microhardness (FSM) and fluoride release were measured. Fluoride dose was measured with a fluoride-specific electrode (Orion 9609-BN) and digital ion analyzer (Orion 720 A). The variables ISM, FSM and fluoride release were analyzed statistically by analysis of variance and Tukey's test (p<0.05). There was significant difference in FSM between the storage media for Vitremer (pH 4.6 = 40.2 ± 1.5; water = 42.6 ± 1.4), Ketac-Fil Plus (pH 4.6 = 73.4 ± 2.7; water = 58.2 ± 1.3) and Fluorofil (pH 4.6 = 44.3 ± 1.8; water = 38.4 ± 1.0). Ketac-Fil Plus (9.9 ± 18.0) and Fluorofil (4.4 ± 1.3) presented higher fluoride release in water, whereas Vitremer (7.4 ± 7.1), Fuji II LC (5.7 ± 4.7) and Freedom (2.1 ± 1.7) had higher fluoride release at pH 4.6. Microhardness and fluoride release of the tested restorative materials varied according to the storage medium.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wollastonite bioceramics prepared from synthetic and natural precursors were implanted in rats in bone and subcutaneous tissues. The implant sites were excised after 7, 30 and 120 days, fixed, dehydrated, embedded in paraffin wax for serial cutting and examined under transmitted light microscope. It was found a very similar behavior for both wollastonite bioceramics. They were biocompatible, bioactive and biodegradable when implanted in rat bone. The synthetic ceramic was more reabsorbable than the one from natural powder. When implanted in subcutaneous rat tissue, both materials elicited a mild initial inflammatory reaction that practically disappeared after 120 days. Both materials were encapsulated with a very thin fibrous capsule and slightly reabsorbed at their surfaces. None of the materials induced ectopic osteogenesis. According to the results, the studied materials seem to be able for manufacturing reabsorbable bone implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The bovine bone and sintetic hydroxyapatite (HA) bioceramics are reference materials to employment as a bone substitute, however, their slow rate of degradation and its low rate of bioactivity index (Ib) are presented as limiting factors for application as bone graft. In contrast, the bioglass is a resorbable and osteoinductive material. the present work objective the development of composites of dispersed bovine bone or sintetic HA in silicate-phosphate bioglass, seeking to obtain a biomaterial with properties suitable for application as bone grafts. The composites were prepared by mixing between the powder components followed by sintering for 1h. Were used HA and bioglass (45S5) with particle size <240μm. The tested proportions of HA/45S5 were 20/80, 30/70 and 40/60 (wt%). The composites characterization was made employing scanning electron microscopy, Infra-Red Spectrometry and hydrolytic resistance test. The test results indicate the potential use of the materials developed for applications such as bone graft. © (2012) Trans Tech Publications, Switzerland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The construction of synthetic cells is one of the major goals of bioengineering. The most successful approach consists in the encapsulation of biochemical materials (DNA, RNA, enzymes, etc.) inside lipid vesicles (liposomes), mimicking a cell structure. In this contribution, that also aims at introducing the reader to 'chemical synthetic biology,' we describe the current state of the art of 'semi-synthetic minimal cells' (SSMCs), namely, cell-like structures containing the minimal number of biological compounds that are required to reconstruct a function of interest. We will first describe how the concept of the minimal cell was originated and its relation with the theory of autopoiesis, then we review the most advanced results focused on genetic/metabolic networks inside liposomes. Next, we emphasize that relevance of physical aspects (too often neglected) that impact on the solute entrapment process, and finally we discuss new technological trends in SSMC research that will probably allow their future use in biotechnology. © 2013 Copyright © 2013 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To determine the immunoreactivity of synthetic Cryptococcus-derived peptides. Materials & methods: A total of 63 B-cell epitopes from previously identified Cryptococcus gattii immunoreactive proteins were synthesized and evaluated as antigens in ELISAs. The peptides were first evaluated for their ability to react against sera from immunocompetent subjects carrying cryptococcal meningitis. Peptides that yielded high sensitivity and specificity in the first test were then retested with sera from individuals with other fungal pathologies for cross-reactivity determination. Results: Six of 63 synthetic peptides were recognized by antibodies in immunoassays, with a specificity of 100%, sensitivity of 78% and low cross-reactivity. Conclusion: We successfully determined the immunoreactivity of selected synthetic peptides of C. gattii derived proteins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this study is to report on the treatment of mandibular Class II furcation defects with enamel matrix protein derivative (EMD) combined with a beta TCP/HA (beta-tricalcium phosphate/hydroxyapatite) alloplastic material. Method and Materials: Thirteen patients were selected. All patients were nonsmokers, systemically healthy, and diagnosed with chronic periodontitis; had not taken medications known to interfere with periodontal tissue health and healing; presented one Class II mandibular furcation defect with horizontal probing equal to or greater than 4 mm at buccal site. The clinical parameters evaluated were probing depth (PD), relative gingival margin position (RGMP), relative vertical clinical attachment level (RVCAL), and relative horizontal clinical attachment level (RHCAL). A paired Student t test was used to detect differences between the baseline and 6-month measurements, with the level of significance of .05. Results: After 6 months, the treatment produced a statistically significant reduction in PD and a significant gain in RVCAL and RHCAL, but no observable change in RGMP. RVCAL ranged from 13.77 (+/- 1.31) at baseline to 12.15 (+/- 1.29) after 6 months, with a mean change of -1.62 +/- 1.00 mm (P<.05). RHCAL ranged from 5.54 (+/- 0.75) to 2.92 (+/- 0.92), with a mean change of -2.62 +/- 0.63 mm (P<.05). After 6 months, 76.92% of the patients improved their diagnosis to Class I furcation defects while 23.08% remained as Class II. Conclusion: The present study has shown that positive clinical results may be expected from the combined treatment of Class II furcation defects with EMD and beta TCP/HA, especially considering the gain of horizontal attachment level. Despite this result, controlled clinical studies are needed to confirm our outcomes.