16 resultados para SAMPLERS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Different geoenvironmental site investigation techniques to assess contamination from a municipal solid waste disposal site in Brazil are presented here. Superficial geophysical investigation (geoelectrical survey), resistivity piezocone penetration tests (RCPTU), soil samples collected with direct-push samplers and water samples collected from monitoring wells were applied in this study. The application of the geoelectrical method was indispensable to identify the presence and flow direction of contamination plumes (leachate) as well as to indicate the most suitable locations for RCPTU tests and soil and water sampling. Chemical analyses of groundwater samples contributed to a better understanding of the flow of the contaminated plume. The piezocone presented some limitations for tropical soils, since the groundwater level is sometimes deeper than the layer which is impenetrable to the cone, and the soil genesis and unsaturated conditions affect soil behavior. The combined interpretation of geoelectrical measurements and soil and water samplings underpinned the interpretation of RCPTU tests. The interpretation of all the test results indicates that the contamination plume has already overreached the landfill's west-northwest borders. Geoenvironmental laboratory test results suggest that contamination from the solid waste disposal site has been developing gradually, indicating the need for continuous monitoring of the groundwater.
Resumo:
Experimental data on the precipitation chemistry in the semi-arid savanna of South Africa is presented in this paper. A total of 901 rainwater samples were collected with automatic wet-only samplers at a rural site, Louis Trichardt, and at an industrial site, Amersfoort, from July 1986 to June 1999. The chemical composition of precipitation was analysed for seven inorganic and two organic ions, using ion chromatography. The most abundant ion was SO(4)(2-) and a large proportion of the precipitation is acidic, with 98% of samples at Amersfoort and 94% at Louis Trichardt having a pH below 5.6 ( average pH of 4.4 and 4.9, respectively). This acidity results from a mixture of mineral and organic acids, with mineral acids being the primary contributors to the precipitation acidity in Amersfoort, while at Louis Trichardt, organic and mineral acids contribute equal amounts of acidity. It was found that the composition of rainwater is controlled by five sources: marine, terrigenous, nitrogenous, biomass burning and anthropogenic sources. The relative contributions of these sources at the two sites were calculated. Anthropogenic sources dominate at Amersfoort and biomass burning at Louis Trichardt. Most ions exhibit a seasonal pattern at Louis Trichardt, with the highest concentrations occurring during the austral spring as a result of agricultural activities and biomass combustion, while at Amersfoort it is less pronounced due to the dominance of relatively constant industrial emissions. The results are compared to observations from other African regions.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A suit able decision-making on managing a contaminated site characterization program is strongly dependent of the diagnosis process. A detailed diagnosis can be done based on a Conceptual Site Model (CSM) elaboration using high resolution site characterization tools. The piezocone (CPTu) test is a high resolution tool which allows attaching several specific sensors, like the resistivity probe. This hybrid device is called the resistivity piezocone (RCPTu). A simulated geo-environmental site characterization program was performed on an erosion site using different tools (direct push tools soil samplers, hollow stem auger (HSA) drilling and RCPTu tests) to develop the CSM for a site similar to the Brazilian conditions. It was observed a good agreement between the site profiles interpreted by the different methods. The resistivity sensor attached to the piezocone improved the interpretation and the decision-making process on site was significantly better for the CSM elaboration. The RCPTu test data also allowed identifying the hydrogeological heterogeneities. The present study shows that the RCPTu test is also a useful and powerful tool to development an accurate CSM in a Brazilian condition, especially in an approach that prioritizes high resolution geo-environmental investigation. © 2013 Taylor & Francis Group.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Entomologia Agrícola) - FCAV
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective of this work is to use the technique of diffusion by concentration gradient films (DGT) for evaluation of dissolved urano in hydro bodies. For this we chose this work as a systems investigation of water bodies in the region of Poços de Caldas, state of Minas Gerais, because, there is a large amount of mining of uranila. The technique to be used to evaluate the potential for dissolved metals analysis involves the use of passive samplers with application in in situ. This allows detection with excellent sensitivity and selectivity allowing the determination of the labile fraction of dissolved metals
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)