58 resultados para Ramp metering.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Injection metering systems are an important option for the development of pesticide application equipment, with advantages relating to minimising the need for disposal of unused pesticide, improving the ease of cleaning and optimising the accuracy of chemical application. For all injection systems, characteristics such as the steady-state accuracy of delivered dose, dose stability and the time response for dose step changes are related to the ability of the system to operate with different chemical formulations. A system designed to inject liquids should be able to accommodate changes in viscosity and density. The aim of this study was to develop a methodology for testing chemical injection systems using liquids with different viscosities. The experimental arrangement simulating applications with injection metering systems used dye and salt solutions as tracers. Tests were conducted to analyse the influence of salt on the characteristics of the water and a viscous solution. Results showed that the salt interfered with the dye stability in the water solution. In tests with a viscous test liquid, the salt was introduced at different steps during the mixing process, providing four different liquids to be analysed in terms of viscosity, density and pH. Some differences in liquid characteristics were found which could influence the performance of the injection systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of the stable and the metastable ferroelectric polarization of poly(vinylidene fluoride), PVDF, was performed using two successive equal sign ramp voltages, mediated by a short-circuit period. Rates from 10 V/s up to 0.7 MV/s were used. Results showed that they follow different formation kinetics; that the stable part decreases for higher ramp voltage rates and its apparent coercive field increases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Predispatch model (PD) calculates a short-term generation policy for power systems. In this work a PD model is proposed that improves two modeling aspects generally neglected in the literature: voltage/reactive power constraints and ramp rate constraints for generating units. Reactive power constraints turn the PD into a non-linear problem and the ramp rate constraints couple the problem dynamically in time domain. The solution of the PD is turned into a harder task when such constraints are introduced. The dual decomposition/ lagrangian relaxation technique is used in the solution approach for handing dynamic constraints. As a result the PD is decomposed into a series of independent Optimal Power Flow (FPO) sub problems, in which the reactive power is represented in detail. The solution of the independent FPO is coordinated by means of Lagrange multipliers, so that dynamic constraints are iteratively satisfied. Comparisons between dispatch policies calculated with and without the representation of ramp rate constraints are performed, using the IEEE 30 bus test system. The results point-out the importance of representing such constraints in the generation dispatch policy. © 2004 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smart micro-grids offer a new challenging domain for power theories and metering techniques, because they include a variety of intermittent power sources which positively impact on power flow and distribution losses, but may cause voltage asymmetry and frequency variation. Due to the limited power capability of smart micro-grids, the voltage distortion can also get worse (in case of supplying non-linear loads), affecting measurement accuracy and possibly causing tripping of protections. In such a context, a reconsideration of power theories is required, since they form the basis for supply and load characterization. A revision of revenue metering techniques is also needed, to ensure a correct penalization of the loads for their responsibility in generating reactive power, voltage unbalance and distortion. This paper shows that the Conservative Power Theory (CPT) provides a suitable background to cope with smart grids characterization and metering needs. Experimental results validate the proposed approach. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a set of performance factors for load characterization and revenue metering. They are based on the Conservative Power Theory, and each of them relates to a specific load non-ideality (unbalance, reactivity, distortion). The performance factors are capable to characterize the load under different operating conditions, considering also the effect of non-negligible line impedances and supply voltage deterioration. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes an approach to load characterization and revenue metering, which accounts for the influence of supply deterioration and line impedance. It makes use of the Conservative Power Theory and aims at characterizing the load from the measurements done at the point of common coupling. Despite the inherent limitations of a single-point measurement, the proposed methodology enables evaluation of power terms, which clarify the effects of reactivity, asymmetry and distortion, and attempts to depurate the power consumption accounted to the load from those terms deriving from supply nonidealities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to develop a laboratory method for time response evaluation on electronically controlled spray equipment using Programmable Logic Controllers (PLCs). For that purpose, a PLC controlled digital drive inverter was set up to drive an asynchronous electric motor linked to a centrifugal pump on a experimental sprayer equipped with electronic flow control. The PLC was operated via RS232 serial communication from a PC computer. A user program was written to control de motor by adjusting the following system variables, all related to the motor speed: time stopped; ramp up and ramp down times, time running at a given constant speed and ramp down time to stop the motor. This set up was used in conjunction with a data acquisition system to perform laboratory tests with an electronically controlled sprayer. Time response for pressure stabilization was measured while changing the pump speed by +/-20%. The results showed that for a 0.2 s ramp time increasing the motor speed, as an example, an AgLogix Flow Control system (Midwest Technologies Inc.) took 22 s in average to readjust the pressure. When decreasing the motor speed, this time response was down to 8 s. General results also showed that this kind of methodology could make easier the definition of standards for tests on electronically controlled application equipment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Currently great emphasis is given for seed metering that assist rigorous demands in relation to longitudinal distribution of seeds, as well as to the index of fails in spacing laws, breaks and double seeds. The evaluation of these variable demands much time and work of attainment of data and processing. The objective of this work went propose to use of graphs of normal probability, facilitating the treatment of the data and decreasing the time of processing. The evaluation methodology consists in the counting of broken seeds, fail spacing and double seeds through the measure of the spacing among seeds, preliminary experiments through combinations of treatments had been carried through whose factors of variation were the level of the reservoir of seeds, the leveling of the seed metering, the speed of displacement and dosage of seeds. The evaluation was carried through in two parts, first through preliminary experiments for elaboration of the graphs of normal probability and later in experiments with bigger sampling for evaluation of the influence of the factors most important. It was done the evaluation of seed metering of rotating internal ring, and the amount of necessary data for the evaluation was very decreased through of the graphs of normal probability that facilitated to prioritize only the significant factors. The dosage of seeds was factor that more important because factor (D) have greater significance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Teve-se o objetivo de avaliar as formas de se misturar o lubrificante sólido grafite nas sementes de milho, as dosagens e a influência desse na distribuição longitudinal e na germinação, em sementes sem e com tratamento fitossanitário, em mecanismo dosador com disco perfurado horizontal. Os fatores analisados foram: distribuição longitudinal das sementes (espaçamentos falhos, múltiplos e aceitáveis) e a porcentagem de germinação aos 7 e aos 14 dias após a instalação no germinador. Concluiu-se que o tratamento fitossanitário aumentou os espaçamentos falhos e múltiplos e reduziu os espaçamentos aceitáveis. O emprego de grafite reduziu os espaçamentos falhos e múltiplos e elevou os espaçamentos aceitáveis. A melhor forma de mistura do grafite ocorreu na máquina de tratamento fitossanitário de sementes. A distribuição longitudinal alcançou seu ponto ótimo com a dosagem de grafite de 3,37 g kg-1 de semente. As variáveis tratamento fitossanitário, mecanismo dosador e grafite não influíram na germinação das sementes de milho.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a new approach and coding scheme for solving economic dispatch problems (ED) in power systems through an effortless hybrid method (EHM). This novel coding scheme can effectively prevent futile searching and also prevents obtaining infeasible solutions through the application of stochastic search methods, consequently dramatically improves search efficiency and solution quality. The dominant constraint of an economic dispatch problem is power balance. The operational constraints, such as generation limitations, ramp rate limits, prohibited operating zones (POZ), network loss are considered for practical operation. Firstly, in the EHM procedure, the output of generator is obtained with a lambda iteration method and without considering POZ and later in a genetic based algorithm this constraint is satisfied. To demonstrate its efficiency, feasibility and fastness, the EHM algorithm was applied to solve constrained ED problems of power systems with 6 and 15 units. The simulation results obtained from the EHM were compared to those achieved from previous literature in terms of solution quality and computational efficiency. Results reveal that the superiority of this method in both aspects of financial and CPU time. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Daily ultrasound examinations were conducted from Days 10 to 60 (ovulation = Day 0) of pregnancy to monitor the conceptus in jennies (n = 12). The embryonic vesicle was first detected on Day 11.5 +/- 0.9 (mean +/- SD; range 10 to 13d) and was mobile until movement ceased (fixation) on Day 15.5 +/- 1.4 (range, 13 to 18d). The vesicle was spherical from Days 10 to 18 (mean growth rate, 3.2 mm/d), non spherical (irregular) with a reduced growth rate (0.5 mm/d) from Days 19 to 29, and then grew at a moderate rate (1.6 mm/d) up to Day 46. on average, detection of the embryo proper (consistently located on the ventral aspect of the yolk sac) and embryonic heartbeat were Days 20.7 +/- 1.2 and 23.5 +/- 1.3, respectively. Formation of the allantoic sac was first detected on Day 24.4 +/- 1.7 and was complete on Day 36.8 +/- 1.6. Descent of the fetus (and formation of the umbilical cord) began on Day 37.9 +/- 1.7 and was complete on Day 44.1 +/- 2.1. Crown-ramp length averaged 3.7, 15.4, 22.7, 37.5 and 59.6 mm on Days 20, 30, 40, 50 and 60, respectively. In general, morphologic features and dates of occurrence were similar to those reported previously in the mare. (C) 1998 by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A tungsten carbide coating on the integrated platform of a transversely heated graphite atomizer (THGA((R))) used together with Pd(NO3)(2) + Mg(NO3)(2) as modifier is proposed for the direct determination of lead in vinegar by graphite furnace atomic absorption spectrometry. The optimized heating program (temperature, ramp time, hold time) of atomizer involved drying stage (110 degrees C, 5 s, 30 s; 130 degrees C, 5 s, 30 s), pyrolysis stage (1000 degrees C, 15 s, 30 s), atomization stage (1800 degrees C, 0 s, 5 s) and clean-out stage (2450 degrees C, I s, 3 s). For 10 mu L of vinegar delivered into the atomizer and calibration using working standard solutions (2.5-20.0 mu g L-1 Pb) in 0.2% (v/v) HNO3, analytical curve with good linear correlation (r = 0.9992) was established. The characteristic mass was 40 pg Pb and the lifetime of the tube was around 730 firings. The limit of detection (LOD) was 0.4 mu g L-1 and the relative standard deviations (n = 12) were typically <8% for a sample containing 25 pg L-1 Pb. Accuracy of the proposed method was checked after direct analysis of 23 vinegar samples. A paired t-test showed that results were in agreement at 95% confidence level with those obtained for acid-digested vinegar samples. The Pb levels varied from 2.8 to 32.4 pg L-1. Accuracy was also checked by means of addition/recovery tests and recovered values varied from 90% to 110%. Additionally, two certified reference materials were analyzed and results were in agreement with certified values at a 95% confidence level. (C) 2006 Elsevier Ltd. All rights reserved.