71 resultados para REFRACTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glassy films of 0.2[Sb(PO3)(3)]-0,8Sb(2)O(3) with 0.8 mum-thickness were deposited on quartz substrates by electron beam evaporation. A contraction in the film thickness (photoinduced decrease in volume) and photobleaching effect associated with a decrease of up to 25% in the index of refraction has been observed in the films after irradiation near the bandgap (3.89 eV), using the 350.7 nm (3.54 eV) Kr+ ion laser line with 2.5 W/cm(2) for 30 min. A loss of 30% in the phosphorus concentration was measured by wavelength dispersive X-ray microanalysis in the film after laser irradiation with 5.0 W/cm(2) for 1.0 h. These photoinduced changes in the samples are dependent on the power density and intensity profile of the laser beam. Using a Lloyd's mirror setup for continuous wave holography it was possible to record holographic gratings with period from 500 nm up to 20 mum and depth profile of similar to50 nm in the films after laser irradiation with 5.0 W/cm(2) for 1 h. Real-time diffraction efficiency measurements have shown that ultraviolet irradiation induces first a refractive index grating formation, and after this, the photocon traction effect takes place generating an irreversible relief grating. Diffraction efficiency up to 10% was achieved for the recorded gratings. 3D-refraction index measurements and atomic force microscopy images are presented. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the two nonconcentric circles billiard, with the inner circle as a refringent medium, in order to study the classical dynamics of a light ray. The eccentricity controls the chaotic sea intensity and the refraction index acts on the integrable portion of the phase space, prompting the appearance and overlapping of isochrone resonances. Numerical results are presented and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we use the approximation of shallow water waves (Margaritondo G 2005 Eur. J. Phys. 26 401) to understand the behaviour of a tsunami in a variable depth. We deduce the shallow water wave equation and the continuity equation that must be satisfied when a wave encounters a discontinuity in the sea depth. A short explanation about how the tsunami hit the west coast of India is given based on the refraction phenomenon. Our procedure also includes a simple numerical calculation suitable for undergraduate students in physics and engineering.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several positioning techniques have been developed to explore the GPS capability to provide precise coordinates in real time. However, a significant problem to all techniques is the ionosphere effect and the troposphere refraction. Recent researches in Brazil, at São Paulo State University (UNESP), have been trying to tackle these problems. In relation to the ionosphere effects it has been developed a model named Mod_Ion. Concerning tropospheric refraction, a model of Numerical Weather Prediction(NWP) has been used to compute the zenithal tropospheric delay (ZTD). These two models have been integrated with two positioning methods: DGPS (Differential GPS) and network RTK (Real Time Kinematic). These two positioning techniques are being investigated at São Paulo State University (UNESP), Brazil. The in-house DGPS software was already finalized and has provided very good results. The network RTK software is still under development. Therefore, only preliminary results from this method using the VRS (Virtual Reference Station) concept are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the past few years the interest is accomplishing a high accuracy positioning increasing. One of the methods that has been applied by the scientific community is the network based on positioning. By using multiple reference station data, it is possible to obtain centimetric positioning in a larger coverage area, in addition to gain in reliability, availability and integrity of the service. Besides, using this concept, it is possible to model the atmospheric effects (troposphere refraction and ionosphere effect). Another important question concerning this topic is related to the transmission of the network corrections to the users. There are some possibilities for this fact and an efficient one is the Virtual Reference Station (VRS) concept. In the VRS concept, a reference station is generated near to the rover receiver (user). This provides a short baseline and the user has the possibility of using a single frequency receiver to accomplish the relative positioning. In order to test this kind of positioning method, a software has been developed at São Paulo State University. In this paper, the methodology applied to generate the VRS data is described and the VRS quality is analyzed by using the Precise Point Positioning (PPP) method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Center for Weather Forecast and Climatic Studies of National Institute for Space Research (CPTEC/INPE) has provided to the Brazilian Geodetic community, since 2004, an alternative to correct the GNSS observables from the tropospheric refraction. Numerical Weather Prediction (NWP) Model is used to generate Zenital Tropospheric Delay (ZTD). For the version 1, it was developed a model with horizontal resolution of 100 km, which was updated with Eta model, with resolution of 20 km. This paper provides the most significative details of the current version, as well an evaluation of its quality, using for such ZTD estimates from GPS data collect at RBMC. Comparing to the old version, considerable improvement could be observed from the new model, mainly in Brasilia and Curitiba, reaching up to 55% improvement. When all stations were used in the quality control, almost null bias and RMS of about 4 to 5 cm could be observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the effect of nitrogen Plasma Immersion Ion Implantation (PIII) on chemical structure, refraction index and surface hardness of plasma-polymerized hexamethyldisilazane (PPHMDSN) thin films. Firstly, polymeric films were deposited at 13.56 MHz radiofrequency (RF) Plasma Enhanced Chemical Vapour Deposition (PECVD) and then, were treated by nitrogen PIII from 15 to 60 min. Fourier Transformed Infrared (FTIR) spectroscopy was employed to analyse the molecular structure of the samples, and it revealed that vibrations modes at 3350 cm(-1), 2960 cm(-1), 1650 cm(-1), 1250 cm(-1) and 1050 cm(-1) were altered by nitrogen PIII. Visible-ultraviolet (vis-UV) spectroscopy was used to evaluate film refractive index and the results showed a slight increase from 1.6 to 1.8 following the implantation time. Nanoindentation revealed a surface hardness rise from 0.5 to 2.3 GPa as PIII treatment time increased. These results indicate nitrogen PIII is very promising in improving optical and mechanical properties of PPHMDSN films.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modern industry has frequently employed ethylene glycol ethers as monomers in plasma polymerization process to produce different types of coatings. In this work we used a stainless steel plasma reactor to grow thin polymeric films from low pressure RF excited plasma of diethylene glycol dimethyl ether. Plasmas were generated at 5W RF power in the range of 16 Pa to 60 Pa. The molecular structure of plasma polymerized films and their optical properties were analyzed by Fourier Transform Infrared Spectroscopy (FTIR) and UltravioletVisible Spectroscopy, respectively. The IR spectra show C-H stretching at 3000-2900 cm(-1), C=O stretching at 1730-1650 cm(-1), C-H bending at 1440-1380 cm(-1), C-O and C-O-C stretching at 1200-1000 cm(-1). The refraction index was around 1.5 and the optical gap calculated from absorption coefficient presented value near 3.8 eV. Water contact angle of the films ranged from 40 degrees to 35 degrees with corresponding surface energy from 66 to 73x10(-7) J. Because of its favorable optical and hydrophilic characteristics these films can be used in ophthalmic industries as glass lenses coatings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Birefringence or double refraction is the decomposition of a ray of light into two rays when it passes through an anisotropic material such as quartz. Sperm cells have been demonstrated to be optically anisotropic. The objective of this study was to evaluate the relationship between the pattern of human sperm head birefringence (SHBF) and DNA damage. A total of 26 patients with normal semen were included. DNA damage (fragmentation and denaturation) was evaluated in the sperm head in the context of birefringence, both total (SHBF-T) and partial (SHBF-P), by terminal deoxyribonucleotidyl transferase (TdT)-mediated dUDP nick-end labelling assay and acridine orange fluorescence, respectively. Positive DNA fragmentation in spermatozoa with SHBF-T (205/1053; 19.5%) was significantly higher (P < 0.0001) than in spermatozoa that presented SHBF-P (60/820; 7.3%). However, the percentage of denatured DNA in spermatozoa with SHBF-T (824/1256; 65.6%) was not significantly different from the ones with SHBF-P (666/1009; 66.0%). In conclusion, the data support a positive relationship between spermatozoa with total SHBF in their head and increased DNA fragmentation. (C) 2011, Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Pesquisar um fator de correção para avaliação do erro refrativo sem a utilização da cicloplegia. MÉTODOS: Foram estudados 623 pacientes (1.246 olhos), de ambos os sexos, com idade entre 3 e 40 anos. As refratometrias estática e dinâmica foram obtidas usando-se o refrator automático Shin-Nippon Accuref-K 9001. A cicloplegia foi obtida com a instilação de uma gota de colírio ciclopentolato a 1%, com refratometria estática 30 minutos após. Os dados foram submetidos à análise estatística usando a técnica do modelo de regressão linear e modelo de regressão múltipla do valor dióptrico com e sem cicloplegia, em função da idade. RESULTADOS: A correlação entre valores dióptricos sem e com cicloplegia quanto ao erro astigmático variou de 81,52% a 92,27%. Quanto ao valor dióptrico esférico, a correlação foi menor (53,57% a 87,78%). O mesmo se observou em relação ao eixo do astigmatismo (28,86% a 58,80%). O modelo de regressão múltipla em função da idade mostrou coeficiente de determinação múltiplo maior para a miopia (86,38%) e astigmatismo (79,79%). O menor coeficiente foi observado para o eixo do astigmatismo (17,70%). CONCLUSÃO: Avaliando-se os erros refrativos com e sem cicloplegia, observou-se alta correlação nas ametropias cilíndricas. Foram desenvolvidas equações matemáticas como fator de correção para refratometrias dos pacientes sem cicloplegia, portadores de ametropias cilíndricas e esféricas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: O objetivo geral foi detectar fatores ambliopigênicos em uma população de pré-escolares, utilizando exames refratométricos e o PhotoScreenerTM (PS) e o objetivo específico foi verificar se a avaliação feita com o PS é útil como método de triagem em campanhas de prevenção de ambliopia em crianças. MÉTODOS: Foi realizado um estudo observacional, prospectivo, de janeiro a dezembro de 2007, avaliando-se 227 crianças pré-escolares, com o intuito de detectar, através da aplicação de um questionário, exames refratométricos e fotografias utilizando o PS, a presença de fatores causadores de ambliopia na população de estudo. Todas as crianças foram avaliadas pelo PS. em seguida, todas as crianças foram submetidas à cicloplegia , sendo avaliadas usando refrator automático Shin Nippon®. As crianças detectadas como portadoras de problemas oculares receberam prescrição óptica, segundo os critérios: hipermetropia maior que +1,50 D, miopia maior que -1,00 D e astigmatismo maior que 1,00 D. Analisaram-se os dados através do teste de concordância de Goodman, estatística descritiva e estudo da especificidade e sensibilidade ao emprego do PS, comparando os resultados com ele obtidos, com os resultados dos outros métodos de avaliação oftalmológica. RESULTADOS: A distribuição entre os sexos foi semelhante, sendo que a maioria das crianças apresentava quatro ou cinco anos de idade. A sensibilidade (S) do PS, comparando-se o resultado obtido neste aparelho com o autorrefrator sob cicloplegia, foi de 50,9%. Já a especificidade foi de 78,9%; valor preditivo positivo 70%; valor preditivo negativo 62,5% e acurácia 65,1%. CONCLUSÕES: Das 101 crianças cujas fotografias tiradas através do PS puderam ser analisadas satisfatoriamente, trinta e seis apresentavam erro refrativo que necessitou de correção. O PS, quando comparado com equivalente esférico do autorrefrator sob cicloplegia, é um método razoável de triagem, embora a sensibilidade não seja boa. Um ponto positivo a ser ressaltado é o considerável valor de especificidade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)