36 resultados para Pressure pain threshold
Resumo:
The aim is to evaluate the influence of oral contraceptive intake and menstrual cycle on the electrical activity and pressure pain threshold from anterior temporal and masseter muscles. Twenty-eight women on reproductive age were selected, 13 OC users and 15 nonusers. They were weekly submitted to electromyography and algometry of the anterior temporal and masseter muscles during three consecutive menstrual cycles. Electrical activities at rest position and PPTs of temporal and masseter muscles were not affected by menstrual cycle or by OCs uses. Comparison between groups demonstrated that working side electrical activity was increased in OC users in both muscles, except during lutheal phase for the anterior temporal. However, comparison within weeks did not demonstrate statistical difference. It was suggested that, in healthy women, oral contraceptive use may influence electrical activity, but different phases of the cycle may not.
Resumo:
A pressure analgesiometric device was developed for unrestrained cats. Eleven cats were studied. Stimulation was via three rounded pins within a bracelet on the forearm. The pins were advanced by manual bladder inflation. Bladder pressure was measured using a strain gauge pressure transducer. The threshold was recorded at the behavioural end point. Thresholds were measured at 5 and 15 min intervals for 2-4 h, after removal/replacement of the cuff, for 120 min after SC butorphanol (0.4 mg/kg), and with mild skin inflammation at the testing site. Data were analysed using ANOVA. Pressure thresholds in untreated cats were around 150 mmHg. The minimum interval for testing was established as 15 min. Data were reproducible over 4 h and beyond 24 h. Thresholds in 5 cats increased (P < 0.05) above baseline for 45 min after butorphanol with a maximum increase of 270 +/- 182 mmHg at 10 min. Thresholds decreased with inflammation. The method appears suitable for feline analgesia investigations. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
This study investigated the effect of low-level laser therapy (LLLT) on the masticatory performance (MP), pressure pain threshold (PPT), and pain intensity in patients with myofascial pain. Twenty-one subjects, with myofascial pain according to Research Diagnostic Criteria/temporomandibular dysfunction, were divided into laser group (n = 12) and placebo group (n = 9) to receive laser therapy (active or placebo) two times per week for 4 weeks. The measured variables were: (1) MP by analysis of the geometric mean diameter (GMD) of the chewed particles using Optocal test material, (2) PPT by a pressure algometer, and (3) pain intensity by the visual analog scale (VAS). Measurements of MP and PPT were obtained at three time points: baseline, at the end of treatment with low-level laser and 30 days after (follow-up). VAS was measured at the same times as above and weekly throughout the laser therapy. The Friedman test was used at a significance level of 5 % for data analysis. The study was approved by the Ethics Committee of the Federal University of Sergipe (CAAE: 0025.0.107.000-10). A reduction in the GMD of crushed particles (p < 0.01) and an increase in PPT (p < 0.05) were seen only in the laser group when comparing the baseline and end-of-treatment values. Both groups showed a decrease in pain intensity at the end of treatment. LLLT promoted an improvement in MP and PPT of the masticatory muscles. © 2012 Springer-Verlag London.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study aimed to evaluate the effectiveness of low intensity laser therapy (LILT) in 30 patients presenting temporomandibular joint (TMJ) pain and mandibular dysfunction in a random and double-blind research design. The sample, divided into experimental group (1) and placebo group (2), was submitted to the treatment with infrared laser (780 nm, 30 mW, 10 s, 6.3 J/cm2) at three TMJ points. The treatment was evaluated throughout six sessions and 15, 30 and 60 days after the end of the therapy, through visual analogue scale (VAS), range of mandibular movements and TMJ pressure pain threshold. The results showed a reduction in VAS (p < 0.001) and through the ANOVA with repeated measures it was observed that the groups did not present statistically significant differences (P = 0.2060), as the averages of the evaluation times (P = 0.3955) and the interaction groups evaluation times (P = 0.3024), considering the MVO. The same occurred for RLE (P = 0.2988, P = 0.1762 and P = 0.7970), LLE (P = 0.3265, P = 0.4143 and P = 0.0696), PPTD (P = 0.1558, P = 0.4695 and P = 0.0737) and PPTE (P = 0.2376, P = 0.3203 and P = 0.0624). For PE, there were not statistically significant differences for groups (P = 0.7017) and the interaction groups evaluation times (P = 0.6678), even so in both groups the PE varied with time (P = 0.0069). © 2005 Blackwell Publishing Ltd.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Strength gain through eccentric isotonic training without changes in clinical signs or blood markers
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Introduction: The myofascial pain syndrome (SDM) is one of the most common causes of musculoskeletal pain. One of the possible treatments for SDM is the type of physiotherapy myofascial manipulation. Objective: This study aimed to analyze the effect of manipulative technique with myofascial pain threshold before and after applying the technique in athletes during competition period. Methods: Participated in the study 62 subjects of both genders, aged between 14 and 38 (19.64 + 4.89), who had myofascial pain syndrome, 32 oh the treatment group and 30 divided equally between control group and the placebo group. All were athletes and operated by the Department of Sport and Leisure in the city of Marilia – SP and were in competitive period. The volunteers were evaluated according to their musculoskeletal symptoms to prove the necessity of performing the technique of myofascial manipulation. Confi rmed the need to assess the pressure pain threshold (LDP) using a digital dynamometer. After the measurement, patients underwent treatment or using the technique of myofascial manipulation, or a sliding surface for the placebo or no treatment for the control group followed by the immediate reassessment of the LDP. Results: The results were normalized by Kolmogrov-Smirnov test (KS). Through the ANOVA test found no differences between the initial LDP thresholds between groups. To compare pre and post LDP of the three groups we used the paired t test. Signifi cant difference (p=0.0001) between the values of pain threshold before and after application of myofascial manipulation for the treated group and not signifi cant for the control group (p=0.45) and placebo (p=0.16). Conclusion: We conclude then that the myofascial manipulation technique is able to increase pain threshold after micro-musculoskeletal injuries in athletes in competitive period.
Resumo:
A model of nociceptive threshold determination was developed for evaluation of NSAID analgesia in cats. In a crossover study, eight cats received carprofen (4 mg/kg), buprenorphine (0.01 mg/kg) or saline (0.3 ml) subcutaneously before intradermal kaolin injection on the antebrachium to induce mild inflammation. Pressure thresholds were measured at the injected site using blunt-ended pins advanced by manual inflation of a bladder within a bracelet. Bladder pressure was recorded as threshold (PT) at the behavioural end point. Baseline PT were recorded before kaolin injection (time 0). PT was measured at 2-10 h intervals for 52 h. PT below the lower 95% confidence interval (CI) of baseline values indicated hyperalgesia. After saline, hyperalgesia was detected from 2-6 h, 22-26 h, and at 30 and 36 h. After carprofen, PT remained within the 95% CI. After buprenorphine, PT remained within the 95% CI except at 2 h. Carprofen and to some extent buprenorphine, prevented inflammatory hyperalgesia. (C) 2007 Elsevier Ltd. All rights reserved.
Electroacupuncture analgesia in dogs: is there a difference between uni- and bi-lateral stimulation?
Resumo:
Objective To compare the analgesic effect of uni- and bi-lateral electroacupuncture (EA) in response to thermal and mechanical nociceptive stimuli and to investigate the cardiorespiratory, endocrine, and behavioral changes in dogs submitted to EA.Study design Prospective, randomized cross-over experimental study.Animals Eight adult, clinically healthy, cross-breed dogs, weighing 13 +/- 4 kg.Methods Dogs underwent electrostimulation at false acupoints (T-false); bilateral EA at acupoints, stomach 36, gall bladder 34 and spleen 6 (T-EA/bil); unilateral EA at the same points (T-EA/uni) or were untreated (T-control). All animals received acepromazine (0.05 mg kg(-1)) IV; and heart rate, pulse oximetry, indirect arterial blood pressure, respiratory rate, PECO2, rectal temperature, and plasma cortisol concentration were measured before, during, and after EA. Analgesia was tested using thoracic and abdominal cutaneous thermal and mechanical stimuli, and an interdigital thermal stimulus. Behavior was classified as calm or restless. Analysis of variance for repeated measures followed by Tukey's test was used for analysis of the data.Results There were no cardiorespiratory differences among the treatments. The cutaneous pain threshold was higher after EA, compared with false points. The latency period was shorter and analgesia was more intense in T-EA/bil than T-EA/uni, when both were compared with T-false and T-control. Six out of eight animals treated with EA were calm during treatment, and 5/8 and 4/8 of the T-false and T-control animals, respectively, were restless. Latency to interdigital thermal stimulation increased in T-EA/bil compared with the others. There was no difference in plasma cortisol concentrations among the treatments.Conclusions Bilateral EA produced a shorter latency period, a greater intensity, and longer duration of analgesia than unilateral stimulation, without stimulating a stress response.Clinical relevance Bilateral EA produces a better analgesic effect than unilateral EA.
Resumo:
Cancer pain is an important clinical problem and may not respond satisfactorily to the current analgesic therapy. We have characterized a novel and potent analgesic peptide, crotalphine, from the venom of the South American rattlesnake Crotalus durissus terrificus. In the present work, the antinociceptive effect of crotalphine was evaluated in a rat model of cancer pain induced by intraplantar injection of Walker 256 carcinoma cells. Intraplantar injection of tumor cells caused the development of hyperalgesia and allodynia, detected on day 5 after tumor cell inoculation. Crotalphine (6 μg/kg), administered p.o., blocked both phenomena. The antinociceptive effect was detected 1 h after treatment and lasted for up to 48 h. Intraplantar injection of nor-binaltorphimine (50 g/paw), a selective antagonist of κ-opioid receptors, antagonized the antinociceptive effect of the peptide, whereas N,N-diallyl-Tyr-Aib-Phe-Leu (ICI 174,864, 10 μg/paw), a selective antagonist of δ-opioid receptors, partially reversed this effect. On the other hand, D-Phe-Cys-Tyr-D-Trp-Orn-Thr-Pen-Thr amide (CTOP, 20 g/paw), an antagonist of μ-opioid receptors, did not modify crotalphine-induced antinociception. These data indicate that crotalphine induces a potent and long lasting opioid-mediated antinociception in cancer pain. © 2013 Elsevier Inc.
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)