254 resultados para Needle bearings


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil e Ambiental - FEB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This note clarifies the design of proportional derivative (PD) controllers for the magnetic levitation systems of micro PM motors proposed in the above paper. It is shown that the PD controllers cannot stabilize the described levited micro motors because it is necessary to use other values of parameters for these controllers. We present necessary and sufficient conditions for the stability of the controlled systems described in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe 14 cases of pilomatrixoma which were diagnosed preoperatively on FNA cytology. In contrast to the literature, our series showed male preponderance and some of the tumours in unusual locations such as thigh and breast. In three patients the rumours were larger than 5 cm. The clinical diagnosis varied from tumour not otherwise defined to sarcoma. The cytologic presentation had features which allowed a correct diagnosis in all cases and included basaloid cells surrounded by delicate pink fibres, shadow cells, giant cells, naked nuclei and calcium deposits. It is concluded that the FNA cytology of pilomatrixoma is characteristic and will allow a conclusive diagnosis even in cases with an aberrant clinical presentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biopsy by fine needle aspiration together with microbiological examination and scanning electron microscopy were evaluated in diagnosis of clinical bovine mastitis in a Prototheca zopfii outbreak. Fine needle aspiration was performed in 21 mammary quarters from ten Holstein cows presenting clinical mastitis caused by P. zopfii. The algae were previously identified in the microbiological examination of milk collected from these cows. Material aspirated from these 21 mammary glands was submitted to cytological staining (Gram, Giemsa and/or Shor staining). Fine needle aspiration enabled cytological identification of the algae in these 21 mammary glands, from which P. zopfii was isolated in the milk. Simultaneously, five mammary fragments collected by fine needle aspiration from these 21 mammary glands presenting clinical mastitis were also submitted to microbiological examination. P. zopfii was also isolated from these five fragments. Scanning electron microscopy technique also identified three of these five P. zopfii strains isolated from mammary fragments collected by cytological aspiration. These results suggest that fine needle aspiration may be an alternative method for the diagnosis of clinical mastitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A seven-year-old Quarter Horse had a serious external genitalia trauma with severe swelling of ventrum, penis, prepuce and scrotum after falling over a fence. Appropriated treatment was rapidly started after clinical examination. During recovery period, the spermatogenesis assess by semen evaluation was not possible due to stallion's inability to ejaculate. Therefore, for testicular evaluation fine needle aspiration cytology (FNAC) was performed. The first FNAC showed a deviation of germ cell line towards immature cells, mainly by primary spermatocytes (59.5%) with very few late spermatids and spermatozoa (2.5% each), and an increased Sertoli cells/germ cells ratio (478/100), which characterized testicular degeneration. One month after the first FNAC, the second exam presented a drastic decrease of Sertoli cells/germ cells ratio (7/100) and marked increase of mature cell number, specially by early and late spermatids (50% and 24.5%, respectively). In this case, the results of both FNAC could demonstrate a partial recovery of spermatogenesis activity. Two months later, the stallion had mated two mares successfully and they became pregnant. In conclusion, the adequate treatment allowed a complete recovery of the stallion's reproductive function, and since semen collection was impossible during treatment, testicular FNAC showed to be an efficient diagnostic method for evaluating acute damage in the spermatogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fifteen stallions of different breeds, age 3-11 years, had their right testicles evaluated by fine needle aspiration cytology (FNAC). Cytological analysis showed the following spermatogenic cell types: spermatogonia (1.6% +/- 1.1); spermatocyte I (3.4% +/- 2.2); spermatocyte II (0.8% +/- 0.7); early spermatids (25.5% +/- 9.5); late spermatids (37.0% +/- 9.3). Spermatozoal numbers were expressed as the spermatic index (SI = 31.5% +/- 8.5) and Sertoli cells mere expressed as the Sertoli cell index (SEI = 20.9% +/- 17.0) (means +/- s.d). Identification of cell types was relatively easy and no immediate adverse effects of aspiration were noted. The results suggest that FNAC of testis may assist clinical diagnosis in the study of male equine infertility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although several methods of testicular biopsy have been proposed previously, testicular fine needle aspiration (FNA) has proved to be the simplest, the most rapid, inexpensive, and overall the least invasive technique for obtaining testicular biopsies Testicular FNA is indicated for fertility investigations in stallions with oligozoospermia or azoospermia It is also used for differential diagnosis of testicular enlargement After sedation the stallion's testis is punctured to obtain testicular parenchyma samples containing cells mainly from the seminiferous epithelium the material obtained is used to perform smears which are analyzed for identification and quantification of term cells and Sertoli cells The results are based on the presence of the cell types found in the smears and the proportions of Sertoli cells per germ cells In addition to being a very useful diagnostic tool, testicular FNA is also used for follow-up examinations, as it is minimally invasive

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study was undertaken to assess whether fine needle aspirates from non-Hodgkins lymphoma (NHL) could be used for growth fraction analysis with proliferating cell nuclear antigen (PCNA) staining and if there was a relationship between the growth fraction and cytomorphologic classification according to the Kiel classification.STUDY DESIGN: the study group consisted of 40 patients with NHL diagnosed by fine needle aspiration (FNA) cytology. The cytologic classification of the lymphomas was made by two cytopathologists on May-Grunwald-Giemsa-stained slides using the Kiel classification. There were 27 cases of low and 13 of high grade lymphoma. The estimation of the growth fraction was made by PCNA immunoreactivity. The PCNA index was quantitated in smears by counting an average of 1,000 cells, and the count teas correlated with the cytomorphologic classification.RESULTS: There was It strong correlation between the PCNA index and lymphoma grading. High grade lymphomas exhibited a mean PCNA positivity of 74.0%, which was significantly higher (P <.001) than that of low grade lymphomas (17.6%).CONCLUSION: Our study showed that PCNA evalua tion is suitable for smears obtained by FNA on NHL, correlates with increasing grades of lymphoma according to the Kiel classification and may offer a method of monitoring treatment of lymphoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different procedures for obtaining a needle biosensor for the determination of glucose to be inserted subcutaneously in vivo, have been compared. Platinum wires with a diameter of 75 mum, teflon-coated were inserted in hypodermic needles and fixed with a two-component epoxy resin. Using a dip-coating procedure, several layers were deposited on electrodes. The first coating was cellulose acetate, the second was immobilized glucose oxidase (GOD) mixed with bovine serum albumin (BSA) and glutaraldheyde, the third coating was a polyurethane coating obtained with commercially available products. A large number of electrodes have been tried and statistically evaluated but they seem to be affected by poor reproducibility evidenced by a large spreading in successive calibration curves. Then, the polyurethane coating has been replaced by a thin polycarbonate membrane salinized and fixed on the tip of the needle. Reproducible results were achieved and first results of in vivo measurements on rabbits are reported.