108 resultados para National Measurement System for Time and Frequency.
Resumo:
The aim of the present study was to compare heart rate variability (HRV) at rest and during exercise using a temporal series obtained with the Polar S810i monitor and a signal from a LYNX® signal conditioner (BIO EMG 1000 model) with a channel configured for the acquisition of ECG signals. Fifteen healthy subjects aged 20.9 ± 1.4 years were analyzed. The subjects remained at rest for 20 min and performed exercise for another 20 min with the workload selected to achieve 60% of submaximal heart rate. RR series were obtained for each individual with a Polar S810i instrument and with an ECG analyzed with a biological signal conditioner. The HRV indices (rMSSD, pNN50, LFnu, HFnu, and LF/HF) were calculated after signal processing and analysis. The unpaired Student t-test and intraclass correlation coefficient were used for data analysis. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV at rest and during exercise. The intraclass correlation coefficient demonstrated satisfactory correlation between the values obtained by the devices at rest (pNN50 = 0.994; rMSSD = 0.995; LFnu = 0.978; HFnu = 0.978; LF/HF = 0.982) and during exercise (pNN50 = 0.869; rMSSD = 0.929; LFnu = 0.973; HFnu = 0.973; LF/HF = 0.942). The calculation of HRV values by means of temporal series obtained from the Polar S810i instrument appears to be as reliable as those obtained by processing the ECG signal captured with a signal conditioner.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In this paper we present a versatile and easy-to-assemble measurement system for structural health monitoring (SHM) based on the electromechanical impedance (EMI) technique. The hardware of the proposed system consists only of a common data acquisition (DAQ) device with external resistors and allows real-time data acquisition from multiple sensors. Besides the low-cost compared to conventional impedance analyzers, the hardware and the software are simple and easier to implement than other measurement systems that have been recently proposed.
Resumo:
We present the results of an intracavity Stark spectroscopy experiment on the fundamental state of (CD3OH)-C-13. We use an optically pumped hybrid waveguide FIR laser, CH2F2 as active molecule, and (CD3OH)-C-13 as absorbent molecule. No Brewster window is needed to separate the lasing gas from the absorbing deuterated methanol. An absorption line is assigned as E(l) symmetry (n, K, J): (1,4,18) --> (1,5,18) and its frequency is measured as 63.08631 cm(-1) with a precision of a few parts in 10(7); two more absorptions are reported and a tentative assignment for one of them.
Resumo:
This work aims to demonstrate an application of telemetry for monitoring process variables. The authors developed the prototype of a dedicated device capable of multiplexing, encoding and transmitting real-time data signals via amplitude-shift keying modulation to remotely located device(s). The prototype development is described in details, enabling the reproduction of the proposed telemetry system for a three-phase motor as well as for other devices. Furthermore, the proposed device has an easy implementation by using of accessible components and low cost, also presenting a tutorial and educational purpose. © 2011 IEEE.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A computer-based sliding mode control (SMC) is analysed. The control law is accomplished using a computer and A/D and D/A converters. Two SMC designs are presented. The first one is a continuous-time conventional SMC design, with a variable structure law, which does not take into consideration the sampling period. The second one is a discrete-time SMC design, with a smooth sliding law, which does not have a structure variable and takes into consideration the sampling period. Both techniques are applied to control an inverted pendulum system. The performance of both the continuous-time and discrete-time controllers are compared. Simulations and experimental results are shown and the effectiveness of the proposed techniques is analysed.
Resumo:
Objective. The aim of this study was to investigate the influence of shortening the etching time on the bond strength of a conventional and a self-etching primer adhesive system used in primary tooth dentin.Methods. Flat dentin surfaces were obtained from 24 primary molars, randomly assigned to 4 experimental groups. The adhesive systems Single Bond and Clearfil SE Bond were applied in two groups according to the manufacturers' recommendations. In the other two groups, the adhesives were applied after half-time of acid etching, 7 s for Single Bond and 10 s for Clearfil SE Primer. Resin crowns were built up and after 24 h storage in water at 37 ° C, the teeth were sectioned to produce beams with cross-sectional area of approximately 0.49 mm(2). Specimens were tested in tension at 0.5 mm/min until failure. Fractured specimens were analyzed to determine the failure mode.Results. Tensile bond strengths for Single Bond in primary dentin were higher than for Clearfil SE Bond. Shortening of acid etching time improved bond strength only for Single Bond, while no statistically significant difference was observed for Clearfil SE Bond when both etching times were compared.Significance. No detrimental effect on bond strength was observed when the time of acid etching was shortened in 50%. Shortening the time for a procedure in a small child without compromising the quality of the work is a very important finding for the practicing pediatric dentist. © 2004 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This investigation was carried out within the Parana sedimentary basin, Brazil, involved the sampling of effluents and groundwater from monitoring stations situated at different sites at São Paulo State, and was realized with the purpose of evaluating the presence of fats, oil and grease (FOG) in different matrices. Several tests were realized with very distinct materials (cooking oil, butter, margarine, pig fat, vacuum pump oil) in order to properly calibrate the spectrophotometric system. Each matrix was dissolved with 1,1,1-trichloroethane and from the stock solutions it was prepared working standards from different dilutions. The data obtained were plotted on absorbance vs. concentration graph that yielded a successful calibration curve when a mineral oil for vacuum pump was utilized in the experiments at a wavelength corresponding to 410 mn. The results obtained for the analyzed samples were compared with the limiting value established by the São Paulo State legislation on the prevention and pollution control of the environment that was established in 8(th) September 1976 by Rule No. 8468.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A randomized double blind and placebo controlled design was used to investigate the hemostatic, biochemical, gastrointestinal and behavioral effects of pre- and postoperative administration of vedaprofen 0.5 mg/kg PO (V), tramadol 2 mg/kg SC (T), their association (VT) or placebo (P) in 40 adult female cats (3.0 +/- 0.32 kg; 1.8 +/- 0.7 years) distributed in groups of 10. Platelet aggregation and bleeding time were measured before and 52 11 after ovariohysterectomy. Serum urea, creatinine, alanine aminotransferase, alkaline phosphatase and gamma-glutamyl transferase concentrations were measured before and 7 days postoperatively. The occurrence of vomiting, frequency and consistency of feces, and behavior were observed for 7 days postoperatively. Morphine (0.5 mg/kg, IM) was used as rescue analgesic. Laboratory variables did not change. Vomiting was observed only after morphine administration. Mild euphoria was observed in T and VT. The perioperative use of vedaprofen and/or tramadol did not modify the hemostatic, biochemical and gastrointestinal function in cats. (C) 2009 ESFM and AAFP. published by Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The time and the distance traveled during the acceleration and the velocity retaking are parameters used for the comparison and the project of vehicles. In this paper equations for the calculation of those parameters are presented. Several criteria are presented for the shift gears. It is also verified the occurrence or not of total slip during the acceleration of the vehicle. The theoretical models were implemented in a developed computational system. Such system was applied in a Mercedes-Benz do Brazil sample vehicle, in order to facilitate comparisons between the simulate values and the experimental road tests. Copyright © 1997 Society of Automotive Engineers, Inc.