57 resultados para GEL ELECTROLYTE


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrochemical lithium intercalation in thin films of CeO2-TiO2 and WO3, prepared by the sol-gel technique was investigated with cyclic voltammetry and spectroelectrochemical techniques in propylene carbonate solutions. A solid state system having the configuration WO3/Ormolyte/CeO2-TiO2 has been assembled. The solid electrolyte, an organically modified electrolyte (ormolyte), was prepared with different [O]/[Li] ratios. The transmittance variation of this system during a potentiostatic step from -0.7 V to 0.8 V was about 35% at 550 nm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrolytes may modify the physical-chemical characteristics of colloidal particle interfaces in suspension, which can favour gel or aggregate formation. The influence of NH4Cl loading on the aggregation and gelation of SnO2 colloidal suspensions was investigated using measurements of rheology, turbidity and infrared spectra. A rapid aggregate growth for samples with Cl- > 20 mM was observed. With increasing age, gelation was observed due to formation of interaggregate bonds. For concentration of Cl- between 20 and 9 mM, the aggregation process was slower allowing the formation of gel with a network which was not destroyed as the gel was submitted to a small rate of shear. As aging continues, the condensation reaction between OH groups gave rise to the formation of Sn-O bonds, irrespective of the electrolyte loading. © 1992 Elsevier Science Publishers B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Unsupported SnO2 membranes were prepared by sol-gel process and characterized by N2 adsorption-desorption isotherms and X-ray diffraction. Results show that the texture of dried samples does not change appreciably with the concentration of electrolyte. All of the pore size range used in ultrafiltration process was screened using sintering temperature between 300 and 700°C. © 1994 Kluwer Academic Publishers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the effect of the concentration of electrolyte and pH on the kinetics of aggregation and gelation processes of SnO2 colloidal suspensions. Creep, creep-recovery, and oscillatory rheological experiments have been done in situ during aggregation and gelation. A phenomenological description of the structure of the colloidal system is given from the time evolution of rheological parameters. The dependence of the equilibrium steady-state shear compliance on the terminal region of clusters or aggregates seems to be a way to determine the beginning of interconnection of aggregates and the gel point. We propose that at this point the equilibrium steady-state compliance is a minimum. The steady-state viscosity determined from creep experiment can be fit with a power law with the extent of the transformation, giving critical exponent s = 0.7 ± 0.1. The value of the critical exponent Δ = 0.78 ± 0.05 was determined from oscillatory experiment. These results indicate that gelation of SnO2 colloidal suspension exhibits the typical scale expected from the scalar percolation theory. © 2000 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A solid state system having the configuration WO 3/Ormolyte/CeO2-TiO2 has been assembled. Syntheses routes for tungsten oxide WO3, and cerium-titanium CeO 2-TiO2 oxide sols, were developed. A novel solid electrolyte - Ormolyte is reported, which were obtained by the sol-gel process, they have a chemical stability due to the covalent bonds between the inorganic and organic phase, and were prepared with different [O]/[L] ratios, being the best for [O]/[L]=15. The variation of transmittance of the electrochromic device using the ormolyte [O]/[L]=15 was 35% (colored state) and 77% (bleached state).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

2-Aminothiazole covalently attached to a silica gel surface was prepared in order to obtain an adsorbent for Hg(II) ions having the following characteristics: good sorption capacity, chemical stability under conditions of use, and, especially, high selectivity. The accumulation voltammetry of mercury(II) was investigated at a carbon paste electrode chemically modified with silica gel functionalized with 2-aminothiazole (SIAMT-CPE). The repetitive cyclic voltammogram of mercury(II) solution in the potential range -0.2 to + 0.6 V versus Ag/AgCl (0.02 mol L-1 KNO3; V = 20 mV s(-1)) show two peaks one at about 0.1 V and other at 0.205 V. The anodic wave peak at 0.205 V is well defined and does not change during the cycles and it was therefore further investigated for analytical purposes using differential pulse anodic stripping voltammetry in differents supporting electrolytes. The mercury response was evaluated with respect to pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. The precision for six determinations (n = 6) of 0.02 and 0.20 mg L-1 Hg(II) was 4.1 and 3.5% (relative standard deviation), respectively. The detection limit was estimated as 0.10 mu g L-1 mercury(II) by means of 3:1 current-to-noise ratio in connection with the optimization of the various parameters involved and using the highest-possible analyser sensitivity. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The serum protein concentration of newborn Holstein calves determined by means of sodium dodecyl sulphate-polyacrylamide (SDS-PAGE) was studied. Blood samples from 40 healthy newborn calves were obtained 48 hours after birth. Calves had been given 3 liters of colostrum within 2 hours after birth, following by dose corresponding by 15% of animal weight each 24 hours. The results showed three different proteinograms: 19 calves had 14 proteins with molecular weights (MW) ranging from 28,000 D to 170,000D (proteinogram 1); 11 calves had 14 proteins with MW ranging from 18,000 to 170,000 D (proteinogram 1); and 10 calves had 12 proteins with MW ranging from 28,000 D to 170,000 D (proteinogram 3). The three groups presented similar IgG levels. The highest serum concentration of ceruloplasmin were verified in proteinogram 3, which had the lowest serum level of protein with MW 58,000D. It was verified a1-antitrypsin only in proteinogram 2, which had no proteins with MW of 42,000 D and 37,000D. The highest serum concentrations of IgA and protein with MW 58,000 D, and the lowest serum levels of transferrin, haptoglobin, and acid glycoprotein were verified in proteinogram 3. Measurement of serum protein concentrations by SDS-PAGE may be useful in monitoring the occurrence of hypogammaglobulinemia and the neonatal disease in calves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram avaliadas amostras de soro sanguíneo de 10 cães sadios e de 12 com linfoma, utilizando-se a eletroforese em gel de poliacrilamida contendo dodecil sulfato de sódio. Houve diferença entre as médias dos teores de proteína total de cães sadios, 7,68g/dL±0,46 e de cães com linfoma, 7,93g/dL±2,49. As concentrações de IgA e IgG não foram diferentes entre os grupos. Os teores das proteínas de pesos moleculares 142000, 110000, 52000, 49000, 24000 e 18000 dáltons foram mais elevados em cães com linfoma. Os cães com linfoma apresentaram concentrações mais elevadas de ceruloplasmina, 43,95mg/dL±18,19, e haptoglobina, 554mg/dL±449,51, e menores de albumina, 2908mg/dL±476,67, em comparação aos cães sadios (ceruloplasmina: 3,42mg/dL±7,44; haptoglobina: 94,54mg/dL±59,50 e albumina: 4207mg/dL±206,18). Conclui-se que concentrações séricas mais elevadas de ceruloplasmina e haptoglobina e menores de albumina podem estar associadas ao linfoma em cães.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming to evaluate the puerperal influence on the proteinogram of Saanen goats, 108 samples of blood serum from 12 goats were collected, and the results were presented at nine times: just after parturition, 1, 3, 5, 7, 10, 15, 21 and 30 days after parturition. Total amount of serum proteins were determined by the biuret technique, and the sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) was used to the protein fractionation. In this last method, 17 protein bands were observed, from which molecular weights varied between 25 KDa and 275 KDa. In addition, it was possible to identify the following protein fractions: immunoglobulin A (180 KDa), ceruloplasmin (115 KDa), transferrin (79 KDa), albumin (65 KDa), heavy-chain immunoglobulin G (58 KDa), haptoglobin (45 KDa), acid glycoprotein (37 KDa) and light-chain immunoglobulin G (28 KDa). Another 9 nonidentified protein fractions presented, each molecular weights equal to 275 KDa, 140 KDa, 125 KDa, 103 KDa, 95 KDa, 41 KDa, 35 KDa, 30 Kda and 25 KDa. The results allow us to conclude that by the first week of puerperium, an improvement of acid glycoprotein occurs, whereas those others protein fractions do not suffer any puerperal influence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo teve como objetivo comparar os níveis plasmáticos de glicose e cortisol de um grupo de eqüinos atletas submetidos ao esforço de longa duração (enduro eqüestre) em distâncias de 30 e 60km, com velocidades médias de 10 e 15km h-1, respectivamente. Os animais foram aleatoriamente separados em dois grupos, sendo que a um deles foi administrada, por via oral, uma pasta eletrolítica hipertônica antes, durante e após as referidas provas. O outro grupo foi usado como controle. Os resultados das concentrações de cortisol revelaram um aumento significativo, no primeiro momento, em que a intensidade do esforço era maior (15km/h), ou com a continuação deste (30km de distância), no segundo momento, para todos os grupos. Os resultados referentes à concentração de glicose permaneceram constantes durante a prova de 30km; entretanto, nos primeiros 20km da prova de 60km, tais resultados revelaram um aumento significativo no grupo controle, retornando a valores basais no momento subseqüente. A reposição eletrolítica tem a sua importância na manutenção do equilíbrio hidroeletrolítico e ácido básico e, no presente estudo, pode ter contribuído para a manutenção da concentração média de glicose plasmática.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances have accelerated the development of biosensors for the analysis of specific gene sequences. In this kind of biosensor, a DNA probe is immobilized on a transducer and the hybridization with the target DNA is monitored by suitable methodology. In the present work, the streptavidin (STA) was encapsulated in thin films siloxane-poly(propylene oxide) hybrids prepared by sol-gel method and deposited on the graphite electrode surface by dip-coating process. Biotinylated 18-mer probes were immobilized through STA and a novel amperometric DNA biosensor for the detection and genotyping of the hepatitis C virus (genotypes 1, 2A/C, 2B and 3) is described. The HCV RNA from serum was submitted to reverse transcriptase-linked polymerase chain reaction (RT-PCR) and biotin-labeled cDNA was obtained. Thus, the cDNA was hybridized to the target-specific oligonucleotide probe immobilized on the graphite electrode surface and following the avidin-peroxidase conjugate was added. The enzymatic response was investigated by constant potential amperometry at -0.45 V versus Ag/AgCl using H2O2 and KI solutions. HCV RNA negative and positive controls and positive samples of sera patients were analyzed and the results were compared to commercial kit. The proposed methodology appeared to be suitable and convenient tool for streptavidin immobilization and diagnose of HCV disease. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)