31 resultados para Fu dan gong xue.
Resumo:
This research analyzes the discourse of teachers of ancient oriental arts, namely: Yoga, Tai Chi Chuan, Kung Fu, Lian Gong, Qwan Ki Do, reveals the meaning that subjects have about what are the benefits to health of those already considered practical alternatives conventional treatment of health. The research uses the phenomenological method specifically the method of the phenomenon. The method first provides a pre-reflection on the oriental arts, exposing not systematically, some curiosities changing between aspects of oriental arts: historical, main teaching methods, styles, the character of struggle, why are linked to health, the benefits of their practices, movements, philosophy, concepts, ways of acting, the roots, the basics. In this article the pre-reflection does not appear to meet the standards of Congress page limit. Rather concentrate on the next step of the research and present the phenomenon situated in the experience of those who have experienced it in the case of the five arts teachers mentioned above. The method performs individual analysis or ideographic analysis of the five discourses of teachers from each oriental art and then conducts the general or nomothetic. The result is presented an analysis of generalities, convergence, divergence and individuality of meanings expressed by the subject, to finally develop a discussion of these data and weave a synthesis. The analyzes reveal that Eastern practices currently as some of these five analyzed here, those involving aspects of struggle and concentration are excellent allied health development and well-being. Understanding the philosophical aspect is inherent in the practice of the movements, although the character of the struggle, which they transmit through knowledge of their origins and roots is the current thinking routine that generates a life philosophy of selfhelp, self-enabling and tranquility preparation to overcome the tensions, disputes, everyday challenges. The speeches also reveal that the psychophysical aspects of diseases are real, because the practices of movements and the physical drilling of these oriental arts have enabled visible improvements in health by working the mental and the physical in an integrated manner. Masters must have all the knowledge to better meet today's society, preserving these cultures, passing them through the generations.
Resumo:
The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.
Treatment of tumor cells with low concentration of 5-Fu hinders the sensitization of dendritic cells
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A greenhouse experiment was conducted in the Soil Science Department of the Botucatu College of Agricultural Sciences (UNESP), Brazil, using a Dark Red Latosol in 25 L pots. The soil was limed to 50 and 70% of base saturation; and doses 0, 10, 20, 30 and 40 t ha-1 of chicken manure were applied, in December of 1999. The experimental design was completely randomized blocks with a factorial arrangement 5x2, 10 treatments and three replications. This work was carried to evaluate leaf number, height plants, fresh and dry weight by aerial part of sweet fennel, and macronutrients and micronutrients removal. The organic fertilization affected the accumulation of N, P, K, S, B and Mn; liming affected the nutrient uptake, except for the Ca, Mg, S and Fe; the interaction of factors affected K, Mg and Mn.
Resumo:
• Aim: To observe the effects of topical application of 5-fluorouracil (5-FU) on the rabbits corneal limbus. • Methods: 5-FU was applied topically to the corneoscleral region of rabbits eyes. The animals were sacrificed immediately or 7, 15, 30 and 60 days later, and tissues were submitted to histological examination. • Results: All animals presented corneoscleral deepithelization close to the site of application during the immediate post-operative period, whereas on the 4th postoperative day ulceration was no longer present. Histological examination showed absence of epithelium and slight edema. After one week (G2), 2 animals presented epithelial defects, thickened epithelium with larger basal cells and loose chromatin, and slight subepithelial edema. The remaining groups showed no alterations. • Conclusion: The 5-FU topically on the corneoscleral limbus postpone the epitelization.
Resumo:
A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160+5 -68 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS Collaboration conducted a month-long data-taking exercise known as the Cosmic Run At Four Tesla in late 2008 in order to complete the commissioning of the experiment for extended operation. The operational lessons resulting from this exercise were addressed in the subsequent shutdown to better prepare CMS for LHC beams in 2009. The cosmic data collected have been invaluable to study the performance of the detectors, to commission the alignment and calibration techniques, and to make several cosmic ray measurements. The experimental setup, conditions, and principal achievements from this data-taking exercise are described along with a review of the preceding integration activities. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were executed, and the trigger synchronisation. Using data from extended cosmic ray runs, the muon, electron/photon, and jet triggers have been validated, and their performance evaluated. Efficiencies were found to be high, resolutions were found to be good, and rates as expected. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS experiment uses self-triggering arrays of drift tubes in the barrel muon trigger to perform the identification of the correct bunch crossing. The identification is unique only if the trigger chain is correctly synchronized. In this paper, the synchronization performed during an extended cosmic ray run is described and the results are reported. The random arrival time of cosmic ray muons allowed several synchronization aspects to be studied and a simple method for the fine synchronization of the Drift Tube Local Trigger at LHC to be developed. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS High-Level Trigger (HLT) is responsible for ensuring that data samples with potentially interesting events are recorded with high efficiency and good quality. This paper gives an overview of the HLT and focuses on its commissioning using cosmic rays. The selection of triggers that were deployed is presented and the online grouping of triggered events into streams and primary datasets is discussed. Tools for online and offline data quality monitoring for the HLT are described, and the operational performance of the muon HLT algorithms is reviewed. The average time taken for the HLT selection and its dependence on detector and operating conditions are presented. The HLT performed reliably and helped provide a large dataset. This dataset has proven to be invaluable for understanding the performance of the trigger and the CMS experiment as a whole. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS Collaboration conducted a month-long data taking exercise, the Cosmic Run At Four Tesla, during October-November 2008, with the goal of commissioning the experiment for extended operation. With all installed detector systems participating, CMS recorded 270 million cosmic ray events with the solenoid at a magnetic field strength of 3.8 T. This paper describes the data flow from the detector through the various online and offline computing systems, as well as the workflows used for recording the data, for aligning and calibrating the detector, and for analysis of the data. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance. © 2010 IOP Publishing Ltd and SISSA.