213 resultados para Fixed prosthesis
Resumo:
Purpose: This study compared the biomechanical behavior of tilted long implant and vertical short implants to support fixed prosthesis in an atrophic maxilla. Materials and Methods: The maxilla model was built based on a tomographic image of the patient. Implant models were based on micro-computer tomography imaging of implants. The different configurations considered were M4S, four vertical anterior implants; M4T, two mesial vertical implants and two distal tilted (45°) implants in the anterior region of the maxilla; and M6S, four vertical anterior implants and two vertical posterior implants. Numerical simulation was carried out under bilateral 150N loads applied in the cantilever region in axial (L1) and oblique (45°) (L2) direction. Bone was analyzed using the maximum and minimum principal stress (σmax and σmin), and von Mises stress (σvM) assessments. Implants were analyzed using the σvM. Results: The higher σmax was observed at: M4T, followed by M6S/L1, M6S/L2, M4S/L2, and M4S/L1 and the higher σvM: M4T/L1, M4T/L2 and M4S/L2, M6S/L2, M4S/L1, and M6S/L1. Conclusions: The presence of distal tilted (all-on-four) and distal short implants (all-on-six) resulted in higher stresses in both situations in the maxillary bone in comparison to the presence of vertical implants (all-on-four). © 2013 Wiley Periodicals, Inc.
Resumo:
The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast in silver-palladium alloy and coated with two occlusal veneering materials: acrylic resin or porcelain. Material and Methods: Two strain gauges were bonded to the inferior surface of the silver-palladium framework and two other were bonded to the occlusal surface of the prosthesis framework covered with ceramic and acrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2 N compression force was applied to the cantilever at 10, 15 and 20 mm from the most distal implant. The measurements of deformation by compression and tension were obtained. The statistical 2-way ANOVA test was used for individual analysis of the experiment variables and the Tukey test was used for the interrelation between all the variables (material and distance of force application). Results: The results showed that both variables had influence on the studied factors (deformation by compression and tension). Conclusion: The ceramic coating provided greater rigidity to the assembly and therefore less distortion compared with the uncoated framework and with the resin-coated framework. The cantilever arm length also influenced the prosthesis rigidity, causing higher deformation the farther the load was applied from the last implant.
Resumo:
Interim restorations are frequently used in prosthodontic treatments. Many complex situations require the combination of fixed and removable partial prostheses. An appropriate interim restoration design that accurately implements the treatment plan is necessary to prepare the oral cavity for the prostheses, and to contribute to the preservation and health of remaining natural teeth, bone support, and gingival tissues. This report describes a modified technique for construction of interim restorations with a combination of fixed and removable partial prostheses. The technique consists of the construction of a milled fixed prosthesis and removable partial denture with metallic framework for use during extensive treatment, improving masticatory function and esthetics and preserving the periodontal health of supporting structures. This interim restoration can also serve as a template for the definitive restoration, allowing patient and dentist to evaluate appearance and function and helping to ensure the success of the definitive restoration.
Resumo:
Background: Considering the limited qualitative and quantitative bone in the posterior arch, this modality of prosthetic treatment could provide a positive emotional factor reestablished by immovability of the anterior fixed implant-supported segment. Objective: This clinical report demonstrates the possibility of achieving positive results with a removable partial denture connected to an implant-supported fixed prosthesis associated to an extra resilient attachment. Clinical significance: In cases of posterior mandibular and maxilla atrophy added to the patients desire against the bone graft, this kind of prosthetic treatment has an important place as an alternative.
Resumo:
Because of the widespread use of implant-supported restorations and that the success of this treatment depends on the passivity of the different component systems of implant-prosthesis, a literature review was performed to highlight issues related to passivity in framework of implant-supported fixed prosthesis. A search of English-language peer-review literature was completed using MEDLINE database (PubMed) focusing on acceptable levels of passivity, misfit classification, problems related to misfit, methods to evaluate misfit, general factors that affect the passivity, and the biologic tolerance in the presence of misfit. The information obtained in the present review suggested that even if it is hard to obtain an implant-supported prosthesis with complete passivity, the professional should use the technological resources to offer better conditions for their patients. An acceptable clinical level of passivity that does not cause any problem to the biologic, aesthetic, and functional parameters of the patient should be sought.
Resumo:
Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic models were fabricated in PL-2 resin and divided according to the implant-abutment connection (external hexagon (EH) and Morse taper (MT) implants (3.75 × 11.5 mm)) and the number crowns (single and 3-unit piece). Models were positioned in a circular polariscope and 100-N axial and oblique (45) loading were applied in the occlusal surface of the crowns by using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using software (Adobe Photoshop). Results. Under axial loading, the MT implants exhibited a lower number of fringes for single-unit crowns than EH implants, whereas for a 3-unit piece the MT implants showed a higher number of fringes vs EH implants. The oblique loading increased the number of fringes for all groups. Conclusion. In conclusion, the MT implant-abutment connection reduced the amount of stress in single-unit crowns, for 3-unit piece crowns the amount of stress was lower using an external hexagon connection. The stress pattern was similar for all groups. Oblique loading promoted a higher stress concentration than axial loading. © Informa Healthcare.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
\ The biologic width is an essential dental space that always needs to be maintained to ensure periodontal health in any dental prosthetic restorations. An iatrogenic partial fixed prosthesis constructed in lower posterior teeth predisposed the development of subgingival caries, which induced violation of the biologic width in involved teeth, resulting in an uncontrolled inflammatory process and periodontal tissue destruction. This clinical report describes a periodontal surgical technique to recover a violated biologic width in lower posterior teeth, by crown lengthening procedure associated with free gingival graft procedure, to ensure the possibility to place a modified partial fixed prosthesis in treated area. The procedure applied to recover the biologic width was crown lengthening with some modifications, associated with modified partial fixed prosthesis to achieve health in treated area. The modified techniques in both surgical and prosthetic procedures were applied to compensate the contraindications to recover biologic width by osteotomy in lower posterior teeth. The result, after 4 years under periodic control, seems to achieve the projected goal. Treating a dental diseased area is necessary to diagnose, eliminate, or control all etiologic factors involved in the process. When the traditional methods are not effective to recover destructed tissues, an alternative, compensatory, and adaptive procedure may be applied to restore the sequelae of the disease, applying a restorative method that respects the biology of involved tissues.
Resumo:
Objective: Transitional implants are indicated for cases in which immediate loading is counter-indicated because a healing period is necessary for osseointegration of the definitive implants. These provisional implants were developed to support an implant-supported fixed prosthesis or overdenture to provide retention, stability, and support. The aim of this article was to conduct a literature review on transitional implants to highlight the characteristics of the transitional implants and their advantages, indications, and contraindications, including the level of osseointegration of such implants according to the functional period. Method and Materials: The present literature review was based on the OldMedline and Medline databases from 1999 to 2010 using the key words "transitional implants" and "temporary implants." Fourteen articles were found: 11 clinical studies or techniques and three histologic and histomorphometric studies. Results: The transitional immediate prostheses were worn by completely and partially edentulous patients. Advantages of transitional implants include complete denture retention, stability, and support; maintenance of chewing, phonetics, and patient comfort; protection of bone grafts; vertical stop during healing period; easy and fast surgical and prosthetic procedures; lower cost in comparison to the definitive implant; and reestablishment of esthetics. The success of transitional implants as conservative treatment for conventional immediate loading is a reality if correctly indicated. Conclusion: Transitional implants are a provisional treatment alternative for completely and partially edentulous patients. However, additional studies are required to evaluate the level of remodeling and repair of the transitional implants under loading. (Quintessence Int 2011; 42: 19-24)
Resumo:
Studies has been reported a significant incidence of chipping of the feldspathic porcelain veneer in zirconia-based restorations. The purpose of this study was to compare the three-point flexural strength (MPa), Weibull parameters, Vickers hardness (VHN) and Vickers indentation fracture toughness (MPa/mm(1/2)) in feldspatic porcelains for metal and for zirconia frameworks. Bar specimens were made with the porcelains e.MaxCeram (EM) and VitaVM9 (V9) for zirconia core, and Duceragold (DG) and VitaVMK95 (VK) for metal core (n = 15). Kruskal-Wallis and Dun test were used for statistical analysis. There was no significant difference (p=0.31) among the porcelains in the flexural strength (Median = 73.2; 74.6; 74.5; 74.4). Weibull calculation presented highest reliability for VK (10.8) followed by em (7.1), V9 (5.7) and DG (5.6). Vickers hardness test showed that em (536.3), V9 (579.9) and VK (522.1) had no difference and DG (489.6) had the lowest value (p<.001). The highest fracture toughness was to VK (1.77), DG (1.58) had an intermediate value while V9 (1.33) and em (1.18) had the lowest values (p<.001). Despite of the suitable flexural strength, reliability and high hardness, the porcelains used to zirconia-based fixed dental prostheses showed lower fracture toughness values.
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Immediate functioning of osseointegrated implants has been widely employed in edentulous patients due to its safety and high predictability. However, viability and success of immediate-loaded implants is defined by factors such as number of implants, distribution and splinting, as well as reduction of oblique loads and excessive occlusal contacts. The indirect composite resin-modified glass enable building of a highly aesthetic prosthesis, combining satisfactory resistance and better force dissipation on occlusal loading. This article describes a resin composite, mandibular fixed prosthesis on osseointegrated implants in immediate function.
Resumo:
The oral rehabilitation with osseointegrated implants is a well-documented treatment with high rate of success. Nevertheless, demands related to treatment time and surgical technique began to appear. In this context, the procedure of immediate loading in which the dental prosthesis is placed right after implant surgery has become a constant practice. Although immediate loading has been an important advance, minimally invasive procedures, such as implant placement without raising a mucoperiosteal flap (flapless) are increasingly being performed. Association of immediate loading with the flapless technique improves acceptance by patients and professionals, because no suturing is required. Moreover, it reduces swelling, bleeding during and after surgery, postoperative pain, surgery time, discomfort and hematoma, as well as the need for postoperative medication. These characteristics ease the stages of rehabilitation soon after implant placement, cooperating with prosthodontist's work. Thus, the proposal of this study is to present a clinical case of oral rehabilitation with osseointegrated implants and fixed prosthesis in both arches, in which the flapless technique was applied, followed by immediate loading. It will discuss the diagnosis, prosthetic planning, surgical/prosthodontic procedures and follow-up for 20 months.