267 resultados para Electrical drives


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents the development and experimental analysis of a special input stage converter for a Trolleybus type vehicle allowing its operation in AC (two wires, single-phase) or DC distribution networks. The architecture of proposed input stage converter is composed by five interleaved boost rectifiers operating in discontinuous conduction mode. Furthermore, due to the power lines characteristics, the proposed input power structure can act as AC to DC or as DC to DC converter providing a proper DC output voltage range required to the DC bus. When operation is AC to DC, the converter is capable to provide high power factor with reduced harmonic distortion for the input current, complying with the restrictions imposed by IEC 61000-3-4 standard. Finally, the main experimental results are presented in order to verify the feasibility of the proposed converter, demonstrating the benefits and the possibility for AC feeding system for trolleybus type vehicle. © 2010 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work it is proposed an optimized dynamic response of parallel operation of two single-phase inverters with no control communication. The optimization aims the tuning of the slopes of P-ω and Q-V curves so that the system is stable, damped and minimum settling time. The slopes are tuned using an algorithm based on evolutionary theory. Simulation and experimental results are presented to prove the feasibility of the proposed approach. © 2010 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes the design and development of a high input power-factor (HPF) AC to AC converter for naval applications using Permanent Magnet Generator (PMG). The proposed converter comprises an isolated three-phase uncontrolled multipulse rectification stage directly connected to a single-phase inverter stage, without the use of DC to DC intermediary stage, resulting in more simplicity for the overall circuitry, assuring robustness, reliability and reduced costs. Furthermore, the multipulse rectifier stage is capable to provide high power factor and input currents with low total harmonic distortion (THD). The output voltage of the PMG varies from 260V rms (220 Hz) to 380V rms (360 Hz), depending on load conditions. The output single-phase inverter stage was designed to operate with wide range of DC bus voltage, maintaining 120V rms, 60 Hz output. Measured total harmonic distortion for the AC output voltage represents less than 2%, at 3.6kW nominal linear load. © 2010 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a three-phase integrated inverter suitable for stand-alone and grid-connected applications. Furthermore, the utilization of the special features of the tri-state coupled with the new space vector modulation allows the converter to present an attractive degree of freedom for the designing of the controllers. Additionally, the control is derived through dq0 transformation, all the system is described and interesting simulation results are available to confirm the proposal. © 2012 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Researches on control for power electronics have looked for original solutions in order to advance renewable resources feasibility, specially the photovoltaic (PV). In this context, for PV renewable energy source the usage of compact, high efficiency, low cost and reliable converters are very attractive. In this context, two improved simplified converters, namely Tri-state Boost and Tri-state Buck-Boost integrated single-phase inverters, are achieved with the presented Tri-state modulation and control schemes, which guarantees the input to output power decoupling control. This feature enhances the field of single-phase PV inverters once the energy storage is mainly inductive. The main features of the proposal are confirmed with some simulations and experimental results. © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to present a simple method for determining the high frequency parameters of a three-phase induction motor to be used in studies involving variable speed drives with PWM three-phase inverters, in which it is necessary to check the effects caused to the motor by the electromagnetic interference, (EMI) in the differential mode, as well as in the common mode. The motor parameters determination is generally performed in adequate laboratories using accurate instruments, such as very expensive RLC bridges. The method proposed here consists in the identification of the motor equivalent electrical circuit parameters in rated frequency and in high frequency through characteristic tests in the laboratory, together with the use of characteristic equations and curves, shown in the references to be mentioned for determining the motor high frequency parasite capacitances and also through system simulations using dedicated software, like Pspice, determining the characteristic waveforms involved in the differential and common mode phenomena, comparing and validating the procedure through published papers [01].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Membrane integrity, as measured by electrical conductivity (EC), is suggested as an indicator of seed vigor in soybean [Glycine max (L.) Merrill] seeds. This study evaluated the effect of storage time and temperature on EC of six soybean seed lots (two lots each of high, medium and low vigor). All seed lots were adjusted to 120 g kg(-1) seed moisture, sealed in aluminum foil packets and placed in storage at 10 and 20 degreesC or stored unsealed in multi-wall paper bags in warehouse (WH) conditions at Lexington, KY, USA for 486 days. Four of the six seed lots were also stored unsealed at 10 degreesC. All seed lots were sampled at 3-month intervals and evaluated for seed moisture (SMC), standard germination (SG) and vigor [accelerated aging (AA) and EC]. After 91 and 204 days in storage, samples initially stored at 20 degreesC and WH were moved to 10 degreesC and sampled at the same intervals. Seed moisture content for unsealed samples equilibrated at 107 g kg(-1) (+/-9 g kg(-1)) in both the WH and 10 degreesC environments. No change in SG occurred for seeds stored sealed (120 g kg(-1)) at 10 degreesC, except for the low vigor seed lots which declined significantly at the last sample date. The AA germination declined significantly for all, seed lots stored sealed at 10 degreesC, however the EC did not change during the same storage period. Seeds stored sealed at 20 degreesC and unsealed in the WH showed rapid declines in AA and SG and significant increases in EC. When these seeds were moved to 10 degreesC, however, the AA continued to decline while the EC remained at the same level (no significant change) for the remainder of the seed storage period. Thus whilst the AA declined in all environments, the EC only increased at higher temperatures (20 degreesC, WH) but showed little change during storage at 10 degreesC. Thus, precautions must be taken if using EC to measure soybean seed vigor following storage at 10 degreesC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vigor of soybean [Glycine max (L.) Merrill] seeds can be evaluated by measuring the electrical conductivity (EC) of the seed soaking solution, which has shown a satisfactory relationship with field seedling emergence, but has not had aproper definition of range yet. This work studies the relationship between EC and soybean seedling emergence both in the field and laboratory conditions, using twenty two seed lots. Seed water content, standard germination and vigor (EC, accelerated aging and cold tests) were evaluated under laboratory conditions using -0.03; -0.20; -0.40 and -0.60 MPa matric potentials, and field seedling emergence was also observed. There was direct relationship between EC and field seedling emergence (FE). Under laboratory conditions, a decreasing relationship was found between EC and FE as water content in the substrate decreased, Relationships between these two parameters were also found when -0.03; -0.20 and -0.40 MPa matric potentials were used. EC tests can be used successfully to evaluate soybean seed vigor and identify lots with higher or lower field emergence potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrical conductivity test is still an excellent tool to evaluate the effect of seeds of various forest and agricultural species and recent studies have been conducted aiming at verifying its application in forest seeds. The objective of this study was to establish a specific methodology to test the electrical conductivity of forest seeds of Zeyheria tuberculosis. Four lots of seeds were used, which were submitted to the germination test, evaluating the percentage of germination, germination speed index and dry mass of seedlings. For the electrical conductivity test, five replicates of 20 seeds installed in three volumes of deionized water (75, 100 and 125 mL) were used and eight periods for seed imbibitions (2, 4, 6, 12, 18, 24, 48 and 72 hour) at 25 degrees C were allowed. The statistical design used was completely random; the comparison of means was performed by Tukey test at 5 % probability. Lot II showed higher germination percentage and speed. The electrical conductivity test allows discrimination of the same batch by the germination test under laboratory conditions. It was possible to separate the seed lot presenting better physiological quality (lot II) from among the other lots. It was recommended the use of 75 or 125 mL of deionized water at a temperature of 25 degrees C to perform the electrical conductivity test.