90 resultados para Distorções harmônicas


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents the development and the main results for an interleaved boost rectifier operating as a special input power stage for a trolleybus type vehicle, allowing its feeding by alternate current (AC) or direct current (DC) distribution power systems. When feeding with two wires (single phase) alternate current distribution system, the converter accomplish active power factor correction, providing a relatively sinusoidal current with low total harmonic distortion (THD) and fully complying with IEC 61000-3-4 standards. In addition, a management control system promotes the required automatic operation changes for the proposed rectifier when the vehicle is changing from the DC distribution power system to the AC distribution power system and vice-versa, keeping its original electrical DC system characteristics for the adjustable speed driver sub-system. The main experimental results for a prototype rated at 150kW are presented, considering its application for a trolleybus with DC adjustable speed driver, demonstrating the proposed converter benefits and the possibility of AC feeding system for trolleybus type vehicle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brazil follows the tendency of some countries to update and/or review their fundamental geodetic network. The adoption of geocentric referentials like SIRGAS 2000, the new official reference system of the Geodetic Brazilian System has been an advance. Changes in referential implies in coordinates changes on the network stations as well as the network geometry. To make use of analogical and digital products which are already known in the old referentials are necessary approaches to the coordinate conversion, which minimize the distortions between the used reference frames. This paper presents a distortion modeling approach between reference frames, based on distortion grid generation by using the Shepard's method. To analyze the approach some experiments were performed with the generation of a 1 degrees x1 degrees distortion grid to model the distortions between SAD 69 (1996) and SIRGAS (2000) frames. The results in the test stations were promising, with an average reduction of 50% in the RMS coordinates after the distortions modeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Brazilian Geodetic Network started to be established in the early 40's, employing classical surveying methods, such as triangulation and trilateration. With the introduction of satellite positioning systems, such as TRANSIT and GPS, that network was densified. That data was adjusted by employing a variety of methods, yielding distortions in the network that need to be understood. In this work, we analyze and interpret study cases in an attempt to understand the distortions in the Brazilian network. For each case, we performed the network adjustment employing the GHOST software suite. The results show that the distortion is least sensitive to the removal of invar baselines in the classical network. The network would be more affected by the inexistence of Laplace stations and Doppler control points, with differences up to 4.5 m.