55 resultados para Deep drawing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A semi solid thin strip continuous casting process was used to obtain 50%wt Pb/50%wtSn strip by single and twin roll processing at speed of 15 m/min. A 50%wt Pb/50%wtSn plate ingot was also cast for rolling conventionally into strips of 1.4 mm thickness and 45 mm width for comparison with those achieved non-conventionally. This hypoeutectic alloy has a solidification interval and fusion temperature of approximately 31 degrees C and 215 degrees C respectively. The casting alloy temperature was around 280 degrees C as measured by a type K immersion thermocouple prior to pouring into a tundish designed to maintain a constant melt flow on the cooling slope during semi solid material production. A nozzle with a weir ensures that the semi solid material is dragged smoothly by the lower roll, producing strip with minimum contamination of slag/oxide. The temperatures of the cooling slope and the lower roll were also monitored using K type thermocouples. The coiled semi solid strip, which has a thickness of 1.5 mm and 45 mm width, was rolled conventionally in order to obtain 1.2 mm thick strip. The coiled thixorolled strip had a thickness of 1.2 mm and achieved practically the same width as the conventional strips. Blanks of 40 mm diameter were cut from the strips in a mechanical press, ready for deep drawing and ironing for mechanical characterization. All the strips achieved from non-conventional processing had the same mechanical performance as those achieved conventionally. The limiting drawing ratio (LDR) achieved was approximately 2.0 for all strips. Microscopy examination was made in order to observe phase segregation during processing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The necessity of adapting the standardized fan models to conditions of higher temperature has emerged due to the growth of concerning referring to the consequences of the gas expelling after the Mont Blanc tunnel accident in Italy and France, where even though, with 100 fans in operation, 41 people died. However, since then, the defied solutions have pointed to aerodynamic disadvantages or have seemed nonappropriate in these conditions. The objective of this work is to present an alternative to the market standard fans considering a new technology in constructing blades. This new technology introduces the use of the stainless steel AISI 409 due to its good adaptation to temperatures higher than 400°C, particularly exposed to temperatures of gas exhaust from tunnels in fire situation. Furthermore, it presents a very good resistance to corrosion and posterior welding and pressing, due to its alloyed elements. The innovation is centered in the process of a deep drawing of metallic shells and posterior welding, in order to keep the ideal aerodynamic superficies for the fan ideal performance. On the other hand, the finite element method, through the elasto-plastic software COSMOS permitted the verification of the thickness and structural stability of the blade in relation to the aerodynamic efforts established in the project. In addition, it is not advisable the fabrication of blades with variable localized thickness not even, non-uniform ones, due to the verified concentration of tensions and the difficulties observed in the forming. In this way, this study recommends the construction of blades with uniform variations of thickness. © 2007 Springer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work approaches the main methods of plastic deformation of metals, with a focus on the deep drawing process. The mechanical properties were evaluated with the tension tests. It is presented the aluminum alloys designation, followed by applying heat treatments and the designation of tempers. The manufacture of aluminum beverage cans is described step by step, in general terms. The main objective is to analyze how different cans background geometries have great influence on the dome reversal. To be able to achieve the goal it was necessary to use cans of different manufacturers, which were used in buckle tests to obtain the reversal pressures, tensile tests and geometric analysis. Finally empirical equations were obtained correlating these variables, and it was observed that the conformation of reforming change significantly it's behavior

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uma análise de dados publicados sobre dietas de aves marinhas oceânicas mostra a predominância de cefalópodes musculares e de distribuição mais superficial nas camadas oceânicas, mas também são importantes as espécies gelatinosas e amoniacais restritas a camadas abaixo dos 300 m da superfície. A princípio, não deveria se esperar que cefalópodes de profundidade fossem considerados presas comuns de aves marinhas oceânicas como reportados por muitos autores. É proposto neste estudo que uma fonte indireta, importante e de fácil obtenção, surgiu com o início das atividades dos barcos atuneiros que operam com espinhel. O hábito de ingerir restos de vísceras de peixes capturados em barcos espinheleiros pode explicar as prováveis conclusões equivocadas de que cefalópodes de profundidade são presas naturais de aves marinhas oceânicas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the building of a hydroelectrical power plant at Ilha Solteira in the Parana River (Brazil), materials of a highly weathered soil Oxisol were extracted from a depth between 5 and 8 m for engineering works. This resulted in an abandoned depression area. The topsoil was not salvaged and the open pit was not backfilled, and as result vegetation hardly or not at all recovered. on the residual saprolite materials, an experimental field was established to assess different soil rehabilitation treatments. Field experiments were initiated in 1992. After soil tillage, two different crops and three different liming strategies were compared, giving six combinations. In addition, two uncropped control treatments, tilled and no-tilled, were established so that a total of eight treatments were assessed. The experimental design consisted of four randomized experimental blocks, which included a total of 32 plots with a plot area of 100 m(2). This experiment was used to study the effectiveness of the soil-reclamation treatments after a 9-year period. Soil samples were taken at three different depths (0-10, 10-20, and 20-40 cm), and they were analyzed routinely for pH, organic-matter content, and cation exchange capacity (CEC). Revegetation of the abandoned saprolite material increased soil organic-matter content and cation exchange capacity (CEC), and to some extent small differences between treatments were evidenced. Exchangeable calcium (Ca) and magnesium (Mg) recovered faster than organic-matter content. A significant linear relationship was found between organic-matter content and CEC, suggesting continued addition of organic material will further approach the value of these parameters to those levels corresponding to natural soils under "Cerrado" vegetation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Comparar a eficácia e segurança da profilaxia com heparina de baixo peso molecular (enoxaparina) versus heparina não fracionada (HNF). MÉTODOS: Setenta e cinco pacientes (59 homens e 16 mulheres ), submetidos a amputação maior dos membros inferiores (30 acima do joelho e 45 abaixo do joelho ), foram tratados ao acaso com HNF subcutânea (5,000 IU -2x/dia ) ou enoxaparina subcutânea (40mg/dia ) durante a hospitalização . A profilaxia teve início 12 horas antes da cirurgia ou , em casos emergenciais , no primeiro dia de pós-operatório. RESULTADOS: Os dois grupos de tratamento foram comparáveis em termos de características gerais . A avaliação da TVP foi feita por meio de exame clínico diário e pelo mapeamento dúplex antes e 5-8 dias após a cirurgia . A TVP foi documentada no lado operado em 9,75% dos pacientes tratados com enoxaparina e em 11,76% dos pacientes tratados com HNF (p=0,92) e houve um caso de TVP bilateral em cada grupo . Sangramentos não foram verificados nos 2 grupos . CONCLUSÃO: A enoxaparina e HNF foram igualmente eficientes e seguras para a profilaxia da TVP em pacientes submetidos à amputação de membros inferiores .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Superficial thrombophlebitis (ST) ascending the lower limbs is a common disease, which may be associated with deep vein thrombosis (DVT) and pulmonary embolism (PE). The aim of this study was to investigate the prevalence of DVT and PE as complications of ascending ST of the lower limbs in the great saphenous vein (GSV) or SSV (SSV) and probable risk factors.Methods. For this study 60 consecutive patients were enrolled with ascending ST of the GSV or SSV, seen between 2000 and 2003 at a public hospital in Botucatu, SP, Brazil. All patients were assessed clinically, by venous Duplex scanning of the lower limbs to confirm ST and test for DVT, and by means of pulmonary scintigraphy to test for PE.Results. In 13 ST cases (21.67%) there was concomitant DVT and 17 ST patients (28.33%) also had PE. Eleven patients had a clinical status suggestive of DVT, but only in eight of these (61.5%), this clinical diagnosis was confirmed. Fourteen patients had a clinical status suggestive of PE, and this diagnosis was confirmed in six cases (35.30%). ST patients who also had DVT and/or PE were given anticoagulant treatment with heparin and warfarin. None of the variables studied was predictive of DVT or PE (P>0.05). However, the presence of varicose veins reduced the risk of patients having DVT (relative risk=9.09; 95%CI:1.75 - 50.00 and P=0.023).Conclusion. The prevalence rates of PE (28.3%) and DVT (21.6%) were elevated in this sample of ascending ST cases, indicating a need for detailed assessment of patients for signs of these complications, including for therapeutic management decision making. [Int Angiol 2009;28:400-8]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)