221 resultados para CO 2


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have used our new pulsed CO(2) laser, operating both on regular and hot bands, to excite the (13)CD(3)OH methanol isotopomer. This has lead to the observation of 13 new high-threshold far-infrared laser emissions (also identified as terahertz laser lines), with frequencies in the range between 24.11 and 102.56 cm(-1) (0.72-3.07 THz). The absorption transitions leading to these new FIR laser emissions have been located by observing the optoacoustic absorption spectra around the CO(2) emissions. Here, we present these new far-infrared laser lines, characterized in wavelength, polarization, offset relative to the center of the pumping CO(2) laser transition, relative intensity, and optimum operation pressure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Therapeutic approaches to chronic actinic cheilitis focus on the removal or destruction of diseased epithelium. The CO(2) laser has become an important therapeutic alternative, achieving clinical resolution in around 90% of patients. Although many laser physical parameters have been reported, some are known for their low potential for scar induction without compromising the success of the results. The aim of this clinicohistological study was to compare the therapeutic responses to two low-morbidity protocols involving a single laser pass. A total of 40 patients with chronic multicentric and microscopically proven disease were randomly submitted to two conservative CO(2) laser protocols using a bilateral comparative model. The degree of histological atypia of the epithelium was determined in 26 patients both pre- and postoperatively for both protocols. Other histological phenomena were assessed in addition to this central analysis parameter. Clinical recurrence occurred in 12.5% of patients for each protocol, together with a significant reduction in the degree of epithelial atypia (p < 0.001), which was occasionally complete. However, no difference was found between the protocols (p > 0.05). Using these morphological parameters it was not possible to determine whether postoperative epithelial atypias in part of the sample were reactive or residual in nature. A few patients may show minor postoperative lesions. Due to their potential to achieve clinical and importantly microscopic resolution, the studied protocols may be used for mild through moderate dysplastic epithelium and clinically diffuse disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The compounds [Fe(ch)(CO)(2)PP3] (1) (ch = chalcone) and [Fe(sba)(CO)(2)PPh3] (2) (sba = sorbic acid) were prepared by irradiating the tetracarbonyltriphenylphosphineiron(0) complex in benzene in the presence of ch or sba. The compounds were characterized by infrared and P-31 NMR spectroscopies. Their electrochemical behavior was investigated by cyclic voltammetry and the results suggest that their oxidations occur by more than one electrochemical step, producing free ch and sba, free PPh3 and solvated Fe(III). It was observed that sba ligand contributes more effectively to the stabilization of metal center in these complexes, the X-ray crystal and molecular structures of 1 and 2 were determined; it was shown that the Fe atom adopts a distorted octahedral coordinated geometry in which three of the sites are occupied by the ch or sba ligand. The [Fe(ch)(CO)(2)PPh3] complex is a monomer and the unit cell of complex 2 contains exist two identical and crystallographically independent molecules of [Fe(sba)(CO)(2)PPh3] which are linked by short hydrogen bonds O-H . . .O (C) 2001 Published by Elsevier B.V. Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The compounds [Fe(bda)(CO)(2)L] and [Fe(ch)(CO)(2)L], (bda=benzylideneacetone; ch=chalcone; L=CO, PPh3) were investigated by thermogravimetry and derivative thermogravimetry (TG and DTG). The fragmentation patterns suggest that the iron atom protects the enone fragment, so that the organic ligands break up with the loss of the pendant aromatic rings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this investigation was to evaluate the cleaning effect of CO 2 on surface topography and composition of failed dental implant surfaces. Ten failed dental implants were retrieved from nine patients (mean age, 46.33 ± 5.81 years) as a result of early or late failure. The implants were divided into two parts: one side of the implant was irradiated with a CO 2 laser (test side), while the other side did not receive irradiation (control side). The CO 2 laser was operated at 1.2 W in a continuous wave for 40 seconds (40 J energy). The handpiece of the CO 2 laser was kept at a distance of 30 mm from the implant surface, resulting in a spot area of 0.031415 cm 2 (38.20 W/cm 2; 1559 J/cm 2) in scanning mode (cervical-apical). One unused dental implant was used as a negative control for both groups. All implant surfaces were examined by scanning electron mi croscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) for element analysis. SEM showed that the surface of the test sides consisted of different degrees of organic residues, appearing mainly as dark stains similar to those observed on the control sides. None of the test surfaces presented alterations such as crater-like alterations, lava-like layers, or melting compared with the nonirradiated surfaces. Foreign elements such as carbon, oxygen, sodium, calcium, and aluminum were detected on both sides. These results suggest that CO 2 laser irradiation does not modify the implant surface, although the cleaning effect was not satisfactory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three pig genetics lineages A, B and C marketed in Brazil, were stunning with the manual electric stunning (Karl Schermer 220-230/250 volts, 45-60 Hz and 1.4 - 1.5 A) and the collective gaseous system (COMBI-BUTINA 90% CO 2). The electric stunning provided higher blood splashed levels in the areas of the inside round (0.477 and 0.26, p ≤ 0.01), shoulder/cranial (0.154 and 0.039, p ≤ 0.005), shoulder/central (0.261 e 0.052, p ≤ 0.001), shoulder/caudal (0.180 and 0.030, p ≤ 0.01), loin/central (0.185 and 0.065, p ≤ 0.01), loin/caudal (0.06 and 0.207, p ≤ 0.01) and loin/lateral external (0.061 and 0.013, p ≤ 0.05), as well as more diffuse blood splashed in the areas of the inside round (0.461 and 0.279, p ≤ 0.05), shoulder/cranial (0.154 and 0.039, p ≤ 0.001), shoulder/central (0.231 and 0.039, p ≤ 0.001) and shoulder/caudal (0.185 and 0.026, p ≤ 0.001). The electric stunning also provided higher skin damage levels in the areas of the shoulder (1.098 and 0.795, p ≤ 0.001), body (1.04 and 0.948, p ≤ 0.05) and ham (0.84 and 0.68, p ≤ 0.001), as well as higher eyelid reflex levels (11.57%) comparatively to the gaseous system (2.86%) of a total of 426 pigs. Small indexes of bone fractures and muscle bruises were found in both systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pigs of three genetics lineages A, B and C marketed in Brazil, with alive weight from 100 to 120 kg were submitted to the manual electric stunning (Karl Schermer 220-230/250 volts, 45-60 Hz and 1.4 -1.5 A) and to the collective gaseous system (COMBI-BUTINA 90% CO 2). Blood samples, for levels determination of creatine phosphokinase (CPK), lactate and cortisol, as well as samples of the semimembranosus muscle (10 g) for the determination of the gene halothane, were collected. Being compared the electric and gaseous stunning systems, the electric stunning did demonstrate to be more stressful providing larger plasmatic concentrations of cortisol (p ≤ 0.001) and lactate (p ≤ 0.001) for the genetic lineages A and C, in the studied conditions. However it didn't observe significant differences beween the sanguine indicators and stunning systems in subject when the lineage B was considered. Significant differences among the genetic lineages A, B and C were obtained being compared the plasmatic values of creatine phosphokinase (p ≤ 0.001), lactate (p ≤ 0.001) and cortisol (p ≤ 0.001) when stunned with the gaseous system, however when the electric system was used only the cortisol values presented significant differences (p ≤ 0.001). The presence of the gene halothane (Nn) was only observed in the lineage B.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal stability and thermal decomposition of succinic acid, sodium succinate and its compounds with Mn(II), Fe(II), Co(II), Ni(II), Cu(II) and Zn(II) were investigated employing simultaneous thermogravimetry and differential thermal analysis (TG-DTA) in nitrogen and carbon dioxide atmospheres and TG-FTIR in nitrogen atmosphere. On heating, in both atmospheres the succinic acid melt and evaporate, while for the sodium succinate the thermal decomposition occurs with the formation of sodium carbonate. For the transition metal succinates the final residue up to 1180 °C in N 2 atmosphere was a mixture of metal and metal oxide in no simple stoichiometric relation, except for Zn compound, where the residue was a small quantity of carbonaceous residue. For the CO 2 atmosphere the final residue up to 980 °C was: MnO, Fe 3O 4, CoO, ZnO and mixtures of Ni, NiO and Cu, Cu 2O.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Physical and chemical adsorption of CO 2 on ZnO surfaces were studied by means of two different implementations of periodic density functional theory. Adsorption energies were computed and compared to values in the literature. In particular, it was found that the calculated equilibrium structure and internuclear distances are in agreement with previous work. CO 2 adsorption was analyzed by inspection of the density of states and electron localization function. Valence bands, band gap and final states of adsorbed CO 2 were investigated and the effect of atomic displacements analyzed. The partial density of states (PDOS) of chemical adsorption of CO 2 on the ZnO(0001) surface show that the p orbitals of CO 2 were mixed with the ZnO valence band state appearing at the top of the valence band and in regions of low-energy conduction band. [Figure not available: see fulltext.] © 2012 Springer-Verlag Berlin Heidelberg.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new species of the mailed catfish genus Harttia is described from the Sao Francisco River drainage, States of Minas Gerais and Bahia, Brazil. The new species is distinguished from congeners by the combination of an abdominal region covered by small bony plates; plates 3-4 times in eye diameter; interorbital width 3.1-4.0 in head length and greater than eye diameter; body width at anal fin origin 6.3-8.3 in standard length; margins of the head and pectoral fin spine of mature males with elongate and conspicuous odontodes; anal fin of males longer than of females. A key to Harttia species and a comparison with other species are provided.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To evaluate the cardiorespiratory effects of continuous infusion of ketamine in hypovolemic dogs anesthetized with desflurane.Design: A prospective experimental study.Animals: Twelve mixed breed dogs allocated into 2 groups: saline (n=6) and ketamine (n=6).Interventions: After obtaining baseline measurements (time [T] 0) in awake dogs, hypovolemia was induced by the removal of 40 mL of blood/kg over 30 minutes. Anesthesia was induced and maintained with desflurane (1.5 minimal alveolar concentration) and 30 minutes later (T75) a continuous intravenous (IV) infusion of saline or ketamine (100 mu g/kg/min) was initiated. Cardiorespiratory evaluations were obtained 15 minutes after hemorrhage (T45), 30 minutes after desflurane anesthesia, and immediately before initiating the infusion (T75), and 5 (T80), 15 (T90), 30 (T105) and 45 (T120) minutes after beginning the infusion.Measurements and main results: Hypovolemia (T45) reduced the arterial blood pressures (systolic arterial pressure, diastolic arterial pressure [DAP] and mean arterial pressure [MAP]), cardiac (CI) and systolic (SI) indexes, and mean pulmonary arterial pressure (PAP) in both groups. After 30 minutes of desflurane anesthesia (T75), an additional decrease of MAP in both groups was observed, heart rate was higher than T0 at T75, T80, T90 and T105 in saline-treated dogs only, and the CI was higher in the ketamine group than in the saline group at T75. Five minutes after starting the infusion (T80), respiratory rate (RR) was lower and the end-tidal CO(2) (ETCO(2)) was higher compared with values at T45 in ketamine-treated dogs. Mean values of ETCO(2) were higher in ketamine than in saline dogs between T75 and T120. The systemic vascular resistance index (SVRI) was decreased between T80 and T120 in ketamine when compared with T45.Conclusions: Continuous IV infusion of ketamine in hypovolemic dogs anesthetized with desflurane induced an increase in ETCO(2), but other cardiorespiratory alterations did not differ from those observed when the same concentration of desflurane was used as the sole anesthetic agent. However, this study did not evaluate the effectiveness of ketamine infusion in reducing desflurane dose requirements in hypovolemic dogs or the cardiorespiratory effects of ketamine-desflurane balanced anesthesia.