49 resultados para Arch of hollow cathode


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new methodology for the adjustment of the preheating process and steady-state operation of electronic ballasts intended for hot-cathode fluorescent lamps. The classical series-resonant parallel-loaded half-bridge inverter is the power stage analyzed in this paper. In addition, the preheating process is based on the imposition of a constant rms current through the electrodes, in order to provide a proper value of the R-h/R-c ratio before the lamp start. According to the proposed methodology, it is possible to set suitable operating points for, the electronic ballast, considering optimal conditions for the lamps electrodes. Therefore, the proposed methodology for setting the preheating and steady-state operation is a complete platform to the design of electronic ballasts for hot-cathode fluorescent lamps.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method based an ion exchange(IE)-atomic absorption spectrometry(AAS) coupled by flow techniques, allowing the determination of formation constants of, at least, the first species of complex systems, in aqueous solution, was developed.The IE-AAS coupling reduces significantly the number of experimental steps in comparison with IE batch methods, resulting in an important increase in analytical rate. The method is simple both from experimental and computational points of view, making possible its utilization by workers without special expertise in the field of complex equilibria in solution. on the other hand, taking into account mainly the amount of hollow cathode lamps available to date, the developed procedure may be applied, within certain limitations, to the study of many systems whose features prevent the use of traditional approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new model for the representation of electrodes' filaments of hot-cathode fluorescent lamps, during preheating processes based on the injection of currents with constant root mean square (rms) values. The main improvement obtained with this model is the prediction of the R-h/R-c ratio during the preheating process, as a function of the preheating time and of the rms current injected in the electrodes. Using the proposed model, it is possible to obtain an estimate of the time interval and the current that should be provided by the electronic ballast, in order to ensure a suitable preheating process. is estimate of time and current can be used as input data in the design of electronic ballasts with programmed lamp start, permitting the prediction of the R-h/R-c ratio during the initial steps of the design (theoretical analysis and digital simulation). Therefore, the use of the proposed model permits to reduce the necessity of several empirical adjustments in the prototype, in order to set the operation of electronic ballasts during the preheating process. This fact reduces time and costs associated to the global design procedure of electronic ballasts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors studied the behavior of calcium phosphate materials used as inlay implants into bone cavities prepared in the zygomatic arch of rats. Fifty male albino rats were divided into four groups as follows: group I-preparation of bone cavities which did not receive any implant material as controls; group II-implants of Interpore 200; group III-implants of experimental hydroxylapatite; group IV-implants of experimental hydroxylapatite combined with collagen. The animals were sacrificed after 5, 15, 30, 60 and 120 days and the specimens were submitted to histological analysis. Results showed that the experimental hydroxylapatite used in group III presented better osteogenic properties compared to the other materials. All tested materials were biocompatible, although group IV presented a more intense inflammatory response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The use of Er:YAG laser operating in the 3 μm range with adjustable power and pulses has become popular for dental and medical practice due to its high photoablative capacity, surgical precision and antimicrobial action. Background data: The existing fiberoptic tips irradiate lasers parallel to the long axes of the tooth limiting its efficiency in the root canal. Methods: We evaluated hollow fiberoptic tips obtained from silicate glass as a means of Er:YAG laser conduction in dental procedures. The fiber tips were molded from capillary tubes with different profiles so that their ends would have cylindric, conical or spherical shapes. The performance of the three fibers as a means of propagation of Er:YAG (λ = 2.94 μm) laser radiation was compared to that of a solid sapphire fiber at 10 Hz and 200 mJ and of 20 Hz and 500 mJ. The profiles of frontal and lateral burning were visualized on thermal paper. Results: Analysis of these profiles demonstrated that the sapphire tip and the hollow fiber of cylindric section did not differ significantly in the profiles of frontal burning, and no lateral burning was detected. The fibers of the conical and spherical sections, although presenting attenuation in the frontal output power, showed a larger burning area in the frontal profile, in addition to producing lateral burning. Conclusions: The results indicate that commercial hollow fiberoptics have advantages such as easy manufacture of the different tip shapes, great adaptability, low cost, and a low loss of transmission. © Mary Ann Liebert, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Duarte MAH, Alves de Aguiar K, Zeferino MA, Vivan RR, Ordinola-Zapata R, Tanomaru-Filho M, Weckwerth PH, Kuga MC. Evaluation of the propylene glycol association on some physical and chemical properties of mineral trioxide aggregate. International Endodontic Journal, 45, 565570, 2012. Abstract Aim To evaluate the influence of propylene glycol (PG) on the flowability, setting time, pH and calcium ion release of mineral trioxide aggregate (MTA). Methodology Mineral trioxide aggregate was mixed with different proportions of PG, as follows: group 1: MTA + 100% distilled water (DW); group 2: MTA + 80% DW and 20% PG; group 3: MTA + 50% DW and 50% PG; group 4: MTA + 20% DW and 80% PG; group 5: MTA + 100% PG. The ANSI/ADA No. 57 was followed for evaluating the flowability and the setting time was measured by using ASTM C266-08. For pH and calcium release analyses, 50 acrylic teeth with root-end cavities were filled with the materials (n = 10) and individually immersed in flasks containing 10 mL deionized water. After 3 h, 24 h, 72 h and 168 h, teeth were placed in new flasks and the water in which each specimen was immersed had its pH determined by a pH metre and the calcium release measured by an atomic absorption spectrophotometer with a calcium-specific hollow cathode lamp. Data were analysed by using one-way anova test for global comparison and by using Tukeys test for individual comparisons. Results The highest value of flowability was observed with MTA + 20% DW and 80% PG and the lowest values were found with MTA + 100% DW. They were significantly different compared to the other groups (P < 0.05). The presence of PG did not affect the pH and calcium release. The MTA + 100% PG favoured the highest (P < 0.05) pH and calcium release after 3 h. Increasing the PG proportion interfered (P < 0.05) with the setting time; when used at the volume of 100% setting did not occur. Conclusion The addition of PG to MTA-Angelus increased its setting time, improved flowability and increased the pH and calcium ion release during the initial post-mixing periods. The ratio of 80% DW 20% PG is recommended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate the use of the center of the incisive papilla as a guide for the selection of the proper width of maxillary dentures in 4 racial groups. Method and Materials: One hundred sixty stone casts were obtained from impressions of the maxillary arch of white, black, mixed, and Asian subjects. The occlusal surfaces of the casts were photocopied and the images placed on a digitizer. The most anterior and posterior points of the papilla and cusp tips of the canines were digitized. Dentofacial Planner Plus software was used to calculate the distance from a line passing through the cusp tips of the canines to the center of the papilla, defined as the midpoint of the anterior and posterior points of the papilla. The selection error (in millimeters) due to the clinical application of the method of the incisive papilla was calculated and analyzed. Results: In all studied racial groups, there was no coincidence between the center of the incisive papilla and the canine line. The utilization of the center of the papilla would lead to the selection of wider artificial teeth. In 24.9% of the white, 19.3% of the mixed, 32.9% of the black, and 15.5% of the Asian populations, errors greater than 4 mm would be present with the utilization of the papilla. Conclusion: The method of the center of the incisive papilla is not accurate, but may aid in initial artificial teeth selection for the racial groups studied. (Quintessence Int 2008;39:841-845)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of the present study was to determine if nitric oxide (NO) acting on the brain of bullfrog (Lithobates catesbeianus) is involved in arterial pressure and heart rate (HR) control by influencing sympathetic activity. We investigated the effect of intracerebroventricular injections of l-NMMA (a nonselective NO synthase inhibitor) on mean arterial blood pressure (MAP), HR and cutaneous vascular conductance (CVC) of pelvic skin after intravenous injection of α or β adrenergic blockers, prazosin or sotalol, respectively. Arterial pressure was directly measured by a telemetry sensor inserted in the aortic arch of animals. l-NMMA increased MAP, but did not change HR. This hypertensive response was inhibited by the pre-treatment with prazosin, but accentuated by sotalol. The effect of l-NMMA on MAP was also inhibited by i.v. injections of the ganglionic blocker, hexamethonium. Thus, NO acting on the brain of bullfrog seems to present a hypotensive effect influencing the sympathetic activity dependent on α and β adrenergic receptors in the periphery. © 2013 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was the development a computer code for simulation and analysis of atomic spectra from databases constructed from the literature. There were created four routines that can be useful for spectroscopic studies in the atomic processes of laser isotope separation. In the first routine, Possible Transitions, the program checks the possible electron transitions from an energy level of the atom present in the database considering the selection rules for an electric dipole transition. The second routine, Locator Transitions, checks the possible electronic transitions within a user-specified spectral region. The routine Spectra Simulator creates simulated spectra using the graphical application gnuplot through lorentzian curve and finally, the routine Electronic Temperature determines the temperature of electronic excitation of the atom, thought the Boltzmann Plot Method. To test the reliability of the program there were obtained experimental emission spectra of a hollow cathode discharge of dysprosium and argon as a buffer gas. The hollow cathode discharge has been subjected to different values of operating currents and pressure of inert gas. The spectra obtained were treated with the assistance of program routines developed (Transition Locator and Spectra Simulator) and temperatures electronic excitation of the atoms of dysprosium in the different discharge conditions were calculated (routine Electronic Temperature). The results showed that the electronic excitation temperature of the neutral dysprosium atoms in the hollow cathode discharge increases with increasing current applied to the cathode and also by increasing the gas pressure buffer. The determination coefficients, R2, obtained by the Electronic Temperature routine using the linear adjust of the Boltzmann Plot Method were greater... (Complete abstract click electronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the development of an electro-mechanical micro-discharges device operating at ambient condition of pressure and temperature, capable to produce plasma jets for surface finishing. The discharges are produced through a needle shape electrode hollow cathode type by which flows the helium gas. The voltage applied on the electrode is provided for an AC/AC switching voltage converter of full-bridge topology. The converter is energized by a power line of 110/220 VAC, 60 Hz and gives a 1000 V peak-to-peak from 5 kHz to 40 kHz square waveform output. The output frequency is defined by a control signal provided by an external signal generator. The equipment setup includes output acquisition of voltage and current and a photo-detector for photo-electrical measurements, which allows an optical characterization of the plasma jet

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A incidência de hastes ocas em brócolis (Brassica oleracea L. var. italica Plenck) depende de vários fatores que afetam a absorção e o transporte de B, elemento responsável pelo aparecimento dessa desordem fisiológica. O trabalho avaliou os efeitos de quatro níveis de nitrogênio e dois níveis de boro e da interação entre eles na incidência de hastes ocas e na produção de brócolis. As doses de N (100, 150, 200 e 250 kg ha-1) foram divididas em quatro aplicações iguais aos 15, 30, 45 e 60 dias após o transplante. O boro (0, 4 e 8 kg ha-1) foi aplicado metade no plantio e a outra metade em cobertura aos 45 dias após o transplante. A massa média das inflorescências e a produção total foram diminuídas com a aplicação de B em função do crescimento mais lento das plantas provocado pela toxicidade desse elemento. Contudo, nas áreas não adubadas com B, a porcentagem de plantas com hastes ocas foi, em média, de 44,14%, sendo que a incidência dessa anomalia sofreu drástica redução com a aplicação de B, onde a maior dose (8 kg ha-1) resultou em apenas 4,52% de inflorescências afetadas. Doses de N superiores a 215,4 kg ha-1 aumentaram o número de plantas com hastes ocas somente nas áreas que não receberam B.