32 resultados para Alternative solution
Resumo:
This article analyzes the electrical parameters of a 3-phase transmission line using a 280-m-high steel tower that has been proposed for the Amazon transmission system in Brazil. The height of the line conductors and the distance between them are intrinsically related to the longitudinal and transverse parameters of the line. Hence, an accurate study is carried out in order to show the electrical variations between a transmission line using the new technology and a conventional 3-phase 440-kV line, considering a wide range of frequencies and variable soil resistivity. First, a brief review of the fundamental theory of line parameters is presented. In addition, by using a digital line model, simulations are carried out in the time domain to analyze possible and critical over-voltage transients on the proposed line representation.
Resumo:
The possibility of thermal treatment plants of municipal wastewater is an alternative solution for the final disposition of the sludge produced on small cities as Barueri, a small town of São Paulo State, Brazil. Combustion and pyrolysis of that municipal waste, occurring respectively in air and nitrogen, have been studied by thermogravimetry (TG) and differential thermal analysis (DTA). The main steps of each case were analyzed and Kissinger plots were used to estimate respective activation energies. DTG peaks are more indicated to represent the condition of maximum reaction rates than DTA peaks.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Urban centers have a huge demand for electricity and the growing problem of the solid waste management generated by their population, a relevant social and administrative problem. The correct disposal of the municipal solid waste (MSW) generated in cities is one of the most complex engineering problems that involves logistics, safety, environmental and energetic aspects for its adequate management. Due to a national policy of solid wastes recently promulgated, Brazilian cities are evaluating the technical and economic feasibility of incinerating the non-recyclable waste. São José dos Campos, a São Paulo State industrialized city, is considering the composting of organic waste for biogas production and mass incineration of non-recyclable waste. This paper presents a waste-to-energy system based on the integration of gas turbines to a MSW incinerator for producing thermal and electric energy as an alternative solution for the solid waste disposal in São José dos Campos, SP. A technical and economic feasibility study for the hybrid combined cycle plant is presented and revealed to be attractive when carbon credit and waste tax are included in the project income. © 2013 Elsevier Ltd.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Schistosomiasis is still an endemic disease in many regions, with 250 million people infected with Schistosoma and about 500,000 deaths per year. Praziquantel (PZQ) is the drug of choice for schistosomiasis treatment, however it is classified as Class II in the Biopharmaceutics Classification System, as its low solubility hinders its performance in biological systems. The use of cyclodextrins is a useful tool to increase the solubility and bioavailability of drugs. The aim of this work was to prepare an inclusion compound of PZQ and methyl-beta-cyclodextrin (MeCD), perform its physico-chemical characterization, and explore its in vitro cytotoxicity. SEM showed a change of the morphological characteristics of PZQ:MeCD crystals, and IR data supported this finding, with changes after interaction with MeCD including effects on the C-H of the aromatic ring, observed at 758 cm(-1). Differential scanning calorimetry measurements revealed that complexation occurred in a 1:1 molar ratio, as evidenced by the lack of a PZQ transition temperature after inclusion into the MeCD cavity. In solution, the PZQ UV spectrum profile in the presence of MeCD was comparable to the PZQ spectrum in a hydrophobic solvent. Phase solubility diagrams showed that there was a 5.5-fold increase in PZQ solubility, and were indicative of a type A(L) isotherm, that was used to determine an association constant (K(a)) of 140.8 M(-1). No cytotoxicity of the PZQ:MeCD inclusion compound was observed in tests using 3T3 cells. The results suggest that the association of PZQ with MeCD could be a good alternative for the treatment of schistosomiasis.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: The aim of this study was to investigate the effectiveness of two alternatives methods for the disinfection of oral cleaning devices. Methods: One type of toothbrush and two types of tongue scrapers (steel and plastic) were tested in this study. Sixteen specimens of each group were cut with standardized dimensions, contaminated separately with Candida albicans, Streptococcus mutans and Staphylococcus aureus and incubated for 24 h. After this, oral cleaning devices were washed in saline solution to remove non-adhered cells and divided into two groups (n = 8), one irradiated in microwave and other immersed in 3.78% sodium perborate solution, and evaluated for microbial recovery. The values of cfu of each group of microorganism after disinfection were compared by Kruskal-Wallis and Dunn non-parametric test, considering 95% of confidence. Results: The toothbrush harboured a significant larger number of viable organisms than the tongue scrapers. The steel tongue scraper was less susceptible to adhesion of the three oral microorganisms. The time required to inactivate all contaminating microorganisms using microwave oven was 1 min and, for the immersion in 3.78% sodium perborate solution, was 2 and 3 h, respectively, for C. albicans and S. mutans/S. aureus. Conclusion: Microwave irradiation proved to be an effective alternative method to the disinfection of tongue cleaners and toothbrushes.
Resumo:
The sol-gel method combined with a spin-coating technique has been successfully applied for the preparation of rare-earth doped silica:germania films used for the fabrication of erbium-doped waveguide amplifiers (EDWA), presenting several advantages over other methods for the preparation of thin films. As with other methods, the sol-gel route also shows some drawbacks, such as cracks related to the thickness of silica films and high hydrolysis rate of certain precursors such as germanium alkoxides. This article describes the preparation and optical characterization of erbium and ytterbium co-doped SiO2:GeO2 crack-free thick films prepared by the sol-gel route combined with a spin-coating technique using a chemically stable non-aqueous germanium oxide solution as an alternative precursor. The non-crystalline films obtained are planar waveguides exhibiting a single mode at 1,550 nm with an average thickness of 3.9 mu m presenting low percentages of porosity evaluated by the Lorentz-Lorenz Effective Medium Approximation, and low stress, according to the refractive index values measured in both transversal electric and magnetic polarizations. Weakly confining core layers (0.3% < Delta n < 0.75%) were obtained according to the refractive index difference between the core and buffer layers, suggesting that low-loss coupling EDWA may be obtained. The life time of the erbium I-4(13/2) metastable state was measured as a function of erbium concentration in different systems and based on these values it is possible to infer that the hydroxyl group was reduced and the formation of rare-earth clusters was avoided.
Resumo:
This paper describes 2 alternative methodologies for the determination of selected aldehydes (formaldehyde, acetaldehyde, propionaldehyde, acrolein, and benzaldehyde) by capillary electrophoresis (CE), the first approach is based on the formation of aldehyde-bisulfite adducts and employs free solution CE with reversed electroosmotic flow and indirect detection, using 10 mmol/L 3,5-dinitrobenzoic acid (pH 4.5) containing 0.2 mmol/L cetyltrimethylammonium bromide as the electrolyte. This novel methodology showed a fairly good sensitivity to concentration, with detection limits with respect to a single aldehyde on the order of 10-40 mu g/L, a reasonable analysis time (separation was achieved in <8 min), and no need for sample manipulation. A second approach was proposed in which 2,4-dinitrophenylhydrazine derivatives of the aldehydes were detected in a micellar electrolyte medium (20 mmol/L berate buffer containing 50 mmol/L sodium dodecyl sulfate and 15 mmol/L beta-cyclodextrin). This latter methodology included a laborious sample preconcentration step and showed much poorer sensitivity (0.5-2 mg/L detection limit, with respect to a single aldehyde), despite the use of sodium chloride to promote sample stacking. Both methodologies proved adequate to evaluate aldehyde levels in vehicular emissions. Samples from the tailpipe exhaust of a passenger car vehicle without a catalytic converter and operated with an ethanol-based fuel were collected and analyzed; the results showed high levels of formaldehyde and acetaldehyde (0.41-6.1 ppm, v/v). The concentrations estimated by the 2 methodologies, which were not in good agreement, suggest the possibility of striking differences in sample collection efficiency, which was not the concern of this work.