73 resultados para Adjustable speed
Resumo:
Multipulse rectifiers can replace a conventional six pulse three-phase rectifier (diode bridge) providing a DC voltage with low ripple, low Total Harmonic Distortion of current (THDi) and a high Power Factor (PF). In this context is presented a multipulse rectifier with generalized Delta-differential autotransformer topology, which can provide any level of DC output voltage for any level of three-phase AC input voltage. This paper presents all the possible configurations for Delta topology in order to choose, through graphics, one configuration that presents reduced weight and volume. The average voltage on the DC bus must be compatible with the DC voltage in the six pulse rectifier used in commercial ASDs. Therefore, it is possible to apply the retrofit technique to replace the conventional bridge rectifier by the proposed multipulse rectifier. Based on mathematic models and simulation results, an 18-pulse rectifier with Delta topology, 220 V of line voltage, 315 V of DC output, and rating 2.5 kW of power was designed, implemented and applied for three different commercial ASDs. Experimental results as voltage and current waveforms and results about PF and THDi will be presented. © 2012 IEEE.
Resumo:
This paper is based on the development and experimental analysis of a DCM Boost interleaved converter suitable for application in traction systems of electrical vehicles pulled by electrical motors (Trolleybus), which are powered by urban DC or AC distribution networks. This front-end structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The architecture of proposed converter is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode. Furthermore, the converter can operate as AC-DC converter, or as DC-DC converter providing the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards. The digital controller has been implemented using a low cost FPGA and developed totally using a hardware description language VHDL and fixed point arithmetic. Thus, two control strategies are evaluated considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, the regular PWM modulation and a current correction PWM modulation. In order to verify the feasibility and performance of the proposed system, experimental results from a 15 kW low power scale prototype are presented, operating in DC and AC conditions.
Resumo:
This paper deals with results of a research and development (R&D) project in cooperation with Electric Power Distribution Company in São Paulo (Brazil) regarding the development and experimental analysis of a new concept of power drive system suitable for application in traction systems of electrical vehicles pulled by electrical motors, which can be powered by urban DC or AC distribution networks. The proposed front-end structure is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode as AC-DC converter, or as DC-DC converter, in order to provide the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards resulting in significant improvements for the trolleybuses systems efficiency and for the urban distribution network costs. Considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, two digital control strategies were evaluated. The digital controller has been implemented using a low cost FPGA (XC3S200) and developed totally using a hardware description language VHDL and fixed point arithmetic. Experimental results from a 15 kW low power scale prototype operating in DC and AC conditions are presented, in order to verify the feasibility and performance of the proposed system. © 2009 IEEE.
Resumo:
This paper presents the development and the main results for an interleaved boost rectifier operating as a special input power stage for a trolleybus type vehicle, allowing its feeding by alternate current (AC) or direct current (DC) distribution power systems. When feeding with two wires (single phase) alternate current distribution system, the converter accomplish active power factor correction, providing a relatively sinusoidal current with low total harmonic distortion (THD) and fully complying with IEC 61000-3-4 standards. In addition, a management control system promotes the required automatic operation changes for the proposed rectifier when the vehicle is changing from the DC distribution power system to the AC distribution power system and vice-versa, keeping its original electrical DC system characteristics for the adjustable speed driver sub-system. The main experimental results for a prototype rated at 150kW are presented, considering its application for a trolleybus with DC adjustable speed driver, demonstrating the proposed converter benefits and the possibility of AC feeding system for trolleybus type vehicle.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Over the years, grinding has been considered one of the most important manufacturing processes. Grinding is a high precision process, and the loss of a single workpiece in this stage of the production is unacceptable, fir the value added to the material is very high due to many processes it has already undergone prior to grinding. This study aims to contribute toward the development of an experimental methodology whereby the pressure and speed of the air layer produced by the high rotation of the grinding wheel is evaluated with and without baffles, i.e., in an optimized grinding operation and in a traditional one. Tests were also carried out with steel samples to check the difference in grinding wheel wear with and without the use of baffles.
Resumo:
The world tendency is the increase of the productivity and the production of pieces more and more sophisticated, with high degree of geometric and dimensional tolerances, with good surface finish and low cost. Rectification is responsible for the final finish in the machining process of a material. However, damages generated in this production phase affect all the resources used in the previous processes. Great part of the problems happennig in the rectification process is due to the enormous temperature generated in this activity because of the machining conditions. The dive speed, which is directly related to the productivity, is considered responsible for the damages that occur during rectification, limiting its values to those that do not cause such damages. In this work, through the variation of the dive speed in the process of cylindrical grinding of type ABNT D6 steel, rationalizing the application of two cutting fluids and using a CBN (cubic boron nitrate) abrasive wheel with vitrified blond, the influence of the dive speed on the surface damages of hardened steels was evaluated. The results allowed to say that the dive speed, associated to an efficient cooling and lubrication, didn't provoke thermal damages (including heated zones, cracks and tension stresses) to the material. Residual stresses and the roughness of rectified materials presented a correlation with the machining conditions. The work concluded that it is possible to increase the productivity without provoking damages in the rectified components.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Power performance evaluation of an electric home fan with triac-based automatic speed control system
Resumo:
In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated.
Resumo:
Based on analyses of high-speed video recordings of cloud-to-ground lightning in Brazil and the USA, the characteristics of positive cloud-to-ground (+CG) leaders are presented. The high frame rates permitted the average, 2-dimensional speeds of development along the paths of the channels to be resolved with good accuracy. The values range from 0.3 to 6.0 x 10(5) ms(-1) with a mean of 2.7 x 10(5) ms(-1). Contrary to what is usually assumed, downward +CG leader speeds are similar to downward -CG leader speeds. Our observations also show that the speeds tend to increase by a factor of 1.1 to 6.5 as they approach the ground. The presence of short duration, recoil leaders (RLs) during the development of positive leaders reveal a highly branched structure that is not usually recorded when using conventional photographic and video cameras. The existence of the RLs may help to explain observations of UHF-VHF radiation during the development of +CG flashes.
Resumo:
A novel single-phase voltage source rectifier capable to achieve High-Power-Factor (HPF) for variable speed refrigeration system application, is proposed in this paper. The proposed system is composed by a single-phase high-power-factor boost rectifier, with two cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by a Field Programmable Gate Array (FPGA), associated with a conventional three-phase IGBT bridge inverter (VSI - Voltage Source Inverter), controlled by a Digital Signal Processor (DSP). The soft-switching technique for the input stage is based on zero-current-switching (ZCS) cells. The rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the EEC61000-3-2 standards. The digital controller for the output stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at a refrigerator prototype.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The methanolic extract of the leaves of the medicinal plant Byrsonima crassa (Malpighiaceae) contain flavonoids with antioxidant activity. They were separated in a preparative scale using high-speed counter-current chromatography. The optimum solvent system used was composed of a mixture of ethyl acetate-n-propanol-water (140:8:80 (v/v/v)) and led to a successful separation between monoglucosilated flavonoids (quercetin-3-O-alpha-L-arabinoside, quercetin-3-O-beta-D-galactoside) and the biflavonoid amentoflavone in only 3.5 h. The purities of quercetin-3-O-alpha-L-arabinoside (95 mg), quercetin-3-O-beta-D-galactoside (16 mg) and the biflavonoid amentoflavone (114 mg) were all isolated at purity over 95%. Identification was performed by H-1 NMR, C-13 NMR and UV analyses. (C) 2004 Published by Elsevier B.V.
Resumo:
It has previously been shown that measurement of the critical speed is a non-invasive method of estimating the blood lactate response during exercise. However, its validity in children has yet to be demonstrated. The aims of this study were: (1) to verify if the critical speed determined in accordance with the protocol of Wakayoshi et al. is a non-invasive means of estimating the swimming speed equivalent to a blood lactate concentration of 4 mmol . l(-1) in children aged 10-12 years; and (2) to establish whether standard of performance has an effect on its determination. Sixteen swimmers were divided into two groups: beginners and trained. They initially completed a protocol for determination of speed equivalent to a blood lactate concentration of 4 mmol . l(-1). Later, during training sessions, maximum efforts were swum over distances of 50, 100 and 200 m for the calculation of the critical speed. The speeds equivalent to a blood lactate concentration of 4 mmol . l(-1) (beginners = 0.82 +/- 0.09 m . s(-1), trained = 1.19 +/- 0.11 m . s(-1); mean +/- s) were significantly faster than the critical speeds (beginners = 0.78 +/- 0.25 m . s(-1), trained = 1.08 +/- 0.04 m . s(-1)) in both groups. There was a high correlation between speed at a blood lactate concentration of 4 mmol . l(-1) and the critical speed for the beginners (r = 0.96, P < 0.001), but not for the trained group (r = 0.60, P > 0.05). The blood lactate concentration corresponding to the critical speed was 2.7 +/- 1.1 and 3.1 +/- 0.4 mmol . l(-1) for the beginners and trained group respectively. The percent difference between speed at a blood lactate concentration of 4 mmol . l(-1) and the critical speed was not significantly different between the two groups. At all distances studied, swimming performance was significantly faster in the trained group. Our results suggest that the critical speed underestimates swimming intensity corresponding to a blood lactate concentration of 4 mmol . l(-1) in children aged 10-12 years and that standard of performance does not affect the determination of the critical speed.